API Users Guide Getting Started - 1 ACR -MotionMa x API User s Guide.
2 - Getting Starte d API Users Guide User I nformatio n ACR Series products are used to co ntrol e lectrical an d mec hanical components of m otion control s ystems . You should tes t your m otion s ystem for saf ety under all po tential con ditions.
API Users Guide Getting Started - 3 Conte nts Getting Started ..................................................................................................................................... 5 Introduction ........................................
4 - Getting Starte d API Users Guide AX_JogStop ............................................................................................................................................................ 12 AX_Home Axis ..............................
API Users Guide Getting Started - 5 Getting Starte d Introdu ction This Guide gi ve basic i nstructions o n the functionali ty and imp lementation o f the Motio nCore.DL L API. Only experience d evelopers o f motion contro l soft ware should attempt to use t his API.
6 - API Comma nd Groups API Users Guide API Com mand Group s Command Gro ups DLL Initialization AX_Initialize Control Start DL L … this must be the fir st call to the D LL AX_IsCard Present Checks for Servo Con troller Presence Parameters AX_UpdateP ara ms Force DL L to Reload All P arameter s from Para meters.
API Users Guide API Comman d Groups - 7 Jogging & Homing AX_JogMi nus JOG SELECT ED AXIS MINUS DIRE CTI ON AX_JogPlus J OG SELECTE D AXIS P LUS DIRECT ION AX_JogMi nusFast JOG SELECTED A XIS MINUS.
8 - API Comma nd Descriptions API Users Guide API Com mand De scriptions (DLL Initialization) AX_InitializeControl Description Sends Ha ndle (. hwnd) of t he Applicatio ns Main For m to the D LL to spa wn its threads.
API Users Guide API Command De scriptions - 9 (Parameter Functions) AX_UpdatePa rams Description For ce DLL to Relo ad All Par ameters fro m Para meters.Cfg File Returns (Integer) 1 on Success, 0 on Failure Arguments No ne VB Exa mple: Privat e Sub UpdateP ara m sBtn_Clic k () ‘ Force DLL to Reload All Para meters fro m Parameters.
10 - API Comm and Descriptions API Users Guide AbsReadout ( 0).Captio n = Format((( EncoderArra y(0) * Val(R esolution0) ) - Wor kOffsetsArra y(0)), " 00.0000") AbsReadout(1 ).Caption = Format(((E ncoderArra y(1) * Val(R esolution1)) - WorkO ffsetsArra y(1)), "0 0.
API Users Guide API Command Des criptions - 11 AX_BitOff Description T urns off any bit e xcept the I nputs Returns (Integer) 1 on Success, 0 on Failure Arguments Glo bal BitNu m as Integer VB Exa mple: Call Ax_B itOff ( 512) ‘Clear Kill Moves t o Card Declarat ion: Public Declare Functio n AX_BitO ff Lib _ "Mo tionCore.
12 - API Comm and Descriptions API Users Guide AX_GetMas terFlags Description Get all 32 M ASTERFLAGS bit s from DL L Returns (Integer) 1 on Succes s, 0 on Fail ure Arguments Glo bal MasterFlag s As S.
API Users Guide API Command Des criptions - 13 Returns (Integer) 1 on Succes s, 0 on Fail ure Arguments Glo bal CurrentA xis as Integer 0 = Axis0 1=Axis1 2=Axis2 VB Exa mple: ‘ To Jo g an Axis Place.
14 - API Comm and Descriptions API Users Guide Place VB Code in a button 'Home X Axis Ret = AX_Ho meAxis (0) HomingActive LblTXT.Cap tion = " Homing .
API Users Guide API Command Des criptions - 15 Declarat ion : Public Dec lare Function AX_StartM DI Lib " MotionCore. DLL" _ () As Integer AX_StopMDI Description End MDI Mo de Signal to D LL.
16 - API Comm and Descriptions API Users Guide Public Dec lare Function AX_SetRov Lib "M otionCore.DL L" _ (ByVal RovVal a s Double) As Integer Public Dec lare Function AX_SetSov Lib "M otionCore.
API Users Guide API Command Des criptions - 17 AX_ SetG raphics Description P ass Screen Coor dinates (in P ixels) of the Zoo mBox to the API for Zoo m operations Returns (Integer) 1 on Succes s, 0 on.
18 - API Comm and Descriptions API Users Guide (Cycle Functions) AX_CycleSta rt Description Cause DLL to Start running t he current Loaded G code file from the Specified Line Returns (Integer) 1 on Su.
API Users Guide API Command Des criptions - 19 Reset Description Settin g these bits i n an Optio n Button will effect a feed hold to the Card This is not a n API functio n but how we effect a Reset R.
20 - I/O Map API Users Guide I/O Map A crol oop I/O Layout Control Signals These bits [ 128-255 ] used by the DLL for co mmunicatio n with the VB and AcroB asic. The M otionCore.D LL depends on the se bits so do n’t use the m in yo ur Vb progr ams for an y other purpo se than as defined belo w.
API Users Guide I/O Map - 21 152 T Strob e Set By ACR-MOT IONMAX wh en a T Code has been Sent to b e serviced b y AcroBasic 153 Tool Change Active Set by ACR -MOTIO NMAX DLL to Signal M6 Sub needs to .
22 - I/O Map API Users Guide 199 Reserved for future use 200 Reserved for future use 202 Progra m Running Set by ACR -MOTIO NMAX signal s that a G Co de pro gram is running I nCycle 203 Progra m Modif.
Ein wichtiger Punkt beim Kauf des Geräts Parker Hannifin acr-motion max api users guide (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Parker Hannifin acr-motion max api users guide noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Parker Hannifin acr-motion max api users guide - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Parker Hannifin acr-motion max api users guide reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Parker Hannifin acr-motion max api users guide erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Parker Hannifin acr-motion max api users guide besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Parker Hannifin acr-motion max api users guide verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Parker Hannifin acr-motion max api users guide. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Parker Hannifin acr-motion max api users guide gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.