ACCULINK 3165 DSU/CSU QUICK REFERENCE Document No. 3165-A2-GL1 1-30.
Copyright 1998 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law . No part of this publication may be copied or distributed.
TM 1 ACCULINK 3165 DSU/CSU Quick Reference Document Number 3165-A2-GL1 1-30 January 1998 Quick Start Procedur e The following procedure is for experienced DSU/CSU users who are familiar with the 3165 DSU/CSU installation process and have no special requirements for their application.
2 97-1557 8 PSTN T1 Network Modem Po we r Modem Po we r F ront P anel 3165 DSU/CSU 3165 DSU/CSU 3165 DSU/CSU Serial Po r t or COM P or t Network Po r t Modem Po r t COM Po r t Network Po r t Modem Po .
3 Configuration Options Configuration options are accessed from the Configuration branch of the front panel menu. DSU ESF Stat 97-15579 Dev HS S T est Pe r f TS t a t LE D ID T1 Prtn Pr tn User T elco.
4 T able 1. Port Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description E530 E530 Port T ype: V .35 V .35 Selects the p ort t yp e: EIA-530A, Port T ype: RS449 RS449 S e l ec t s th e por t t ype: EIA - 530A , V .35, RS449, or X.
5 T able 1. Port Configuration Options (2 of 2) Option Comments/Description Factory 2 Factory 1 10E–4 10E–4 10E–5 10E–5 Err Rate: (Excessive Error 10E–6 10E–6 Selects the error rate threshold for Excessive Error Rate Alarm (Excessive Error Rate) 10E–7 10E–7 Excessive Error Rate Alarm.
6 T able 3. Channel Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description Block Block Determines how channels are Assign By: ACAMI ACAMI Determines how channels are assigned: contiguous blocks, ACAMI i di id l h l Assign By: Chan Chan assigned: contiguous blocks, ACAMI or individual channels.
7 T able 3. Channel Configuration Options (2 of 2) Clear Clear Clears (unassigns) channels for this port. Start At: N1 (D1) N2 (D2) N3 (D3) N4 (D4) N5 (D5) N6 (D6) N7 (D7) N8 (D8) N9 (D9) N10 (D10) N1.
8 T able 4. General Configuration Options Option Factory 1 Factory 2 Comments/Description Gen Y ellow: Enab Enab Y ellow alarm is g enerated b y the G en Y e ll ow: (Generate Y ellow) Disab Disab Y e ll ow a l arm i s genera t e d b y th e DSU/CSU on LOS, LOF , or AIS.
9 T able 5. User Configuration Options (1 of 3) Option Factory 1 Factory 2 Comments/Description Self - T est: Enab Enab Allows bypass of self-test on Self-T est: Disab Disab Allows bypass of self - test on initialization.
10 T able 5. User Configuration Options (2 of 3) Option Comments/Description Factory 2 Factory 1 CStop Bits: 1 1 CStop Bits: (Communication Port St Bit ) 1.5 1.5 Selects the number of stop bits for the COM p ort. (Communication Port Stop Bits) 2 2 th e COM por t .
11 T able 5. User Configuration Options (3 of 3) Option Comments/Description Factory 2 Factory 1 5 5 MoDiscTm: ( Modem Port Up Up Specifies the period of inactivity (1 t 60 i t ) th t (M o d em P or t Disconnect T ime) Down Down Specifies the period of inactivity (1 to 60 minutes) that causes a disconnect if MInActTm is enabled.
12 T able 6. Alarm Configuration Options Option Factory 1 Factory 2 Comments/Description Disab Disab Does not display alarm messages. Al M Modem Modem Sends alarm messages to Modem port. Alrm Msg: Com Com Sends alarm messages to COM port. Both Both Sends alarm messages to both ports.
13 T able 7. Management – General Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description SNMP Mgt: Disab Disab Specifies whether the DSU/CSU responds to SNMP session SNMP Mgt: Enab Enab p responds to SNMP session requests.
14 T able 7. Management – General Configuration Options (2 of 2) Option Comments/Description Factory 2 Factory 1 Com NetMask: Edit Edit The Subnet Mask needed to access the device when the COM Com NetMask: Clear Clear access the device when the COM port is configured for SNMP .
15 T able 8. Management – T rap Configuration Options Option Factory 1 Factory 2 Comments/Description Num T rap Mgrs: 1 2–6 1 2–6 The number of trap managers supported by the device. T rap n IP Adr: Edit Edit Specifies the IP address for each trap manager .
16 Notes.
Ein wichtiger Punkt beim Kauf des Geräts Paradyne 3165 DSU/CSU (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Paradyne 3165 DSU/CSU noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Paradyne 3165 DSU/CSU - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Paradyne 3165 DSU/CSU reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Paradyne 3165 DSU/CSU erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Paradyne 3165 DSU/CSU besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Paradyne 3165 DSU/CSU verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Paradyne 3165 DSU/CSU. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Paradyne 3165 DSU/CSU gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.