Benutzeranleitung / Produktwartung FLEXWARE FW-SP-250 des Produzenten Outback Power Systems
Zur Seite of 22
Sur ge P r ot ec tor FW -SP-A CA FW -SP-250 FW -SP-R U ser ’ s Guide Includes M ounting and Installation.
About OutBack P ower S ystems OutBack P ower Systems is a leader in advanced ener gy conversion t echnology . Our products include true sine wave in verter/chargers, maximum power point char ge controllers, syst em com- munication components, as well as br eaker panels, breakers, accessories, and assembled syst ems.
2 W arranty I ntroduction Dear OutBack Customer , Thank you for y our purchase of OutBack products. We make every e or t to assur e our power con- version products will give y ou long and reliable ser vice for your r enewable energy system.
OUTBACK FLEX ware Surge P rotector INST ALLA TION GUIDELINES AND SAFET Y INSTRUC TIONS This product is intended to be installed as part of a permanently grounded electrical system . • The FLEXware Sur ge P rotector is designed f or indoor installation or installation inside a weatherproof enclosure .
INTRODUC TION The OutBack FLEXware Sur ge Pr otec tor connects to the f ollowing FX Ser ies Inverter/Charger por ts: • DC+ • DC- • AC HO T IN • AC NEUTRAL IN • AC HO T OUT • AC NEUTRAL OUT • GROUND The FLEXware Sur ge Pr otec tor is desig ned to protect the FX’ s sensitive components from excessively high v oltages (e.
The FLEX ware Surge P rotector Speci cations LEDs • AC TIVE lights are y ellow (power is present). • ERROR lights are red (pr otection in that circuit is compromised , replacing the surge pr otec tor is recommended). • F or the ERR OR light to show , its circuit must be pow ered; its ACTIVE light will also glow.
FW-SP -ACA The FW-SP -ACA consists of an FW-A CA with an included surge prot ector and is installed onto an FX Series Inver ter/Char ger . Figur e 4: FLEXware Sur ge Pr otec tor -ACA LEDs Underside sc.
(1) Remove the DC C or T urbo (secured by four Phillips corner screws) (2) Remove the DC battery caps (under the DCC or T urbo) (3) Remove the AC Wiring Compartment plastic cover (secured with two Phi.
(7) Remove the appropriate knockouts for the individual power application. Note that knockouts should be scored rst with a utility knife and then removed . The dual, concentric knock out on the back o ers openings for the FW500, FW1000, PS2 and PS4 AC enclosures .
9 (11) Inser t a bushing into the AC enclosur e (it is not critical that this bushing line up precisely with the FW-SP -ACA); if exible cable is used instead of an enclosure , appropriate strain relief is r equired.
FW-SP -250 The FW-SP -250 is a two-piece combined FLEXware 250 top cover and FLEX ware Surge P rotector . I t replaces an existing FLEXwar e 250 cover , attaching at the AC end of the FLEXware 250. Pr ocedure The FLEXware 250 A C should already be installed (see FW250 AC instructions) and all AC and DC power shut o .
(8) Route the FW-SP -250 wires through to the A C Wiring Compartment and to the batter y lugs. (9) Secure the surge pr otec tor’ s wiring in the appropriate locations and replace the various plastic covers as per the wiring instructions on page 16. 11 (5) Install the top section of the cover contain- ing the surge prot ector rst.
Figur e 11: FW-ACA (2) Remove the FW-A CA plastic cover (secured with two Phillips screws) (3) Remove the FW- ACA Bracket (secured with one Phillips screw); if a damaged FLEXware Sur ge Pr otec tor is.
1/ 3/07 The locating pin on the FW-ACA bracket ts in this slot (4) P ass the FW-SP -R wires through the FW - ACA Bracket opening, lining up the locating pin with the slot on the surge prot ector .
(5) With the FW-SP-R attached t o the FW-ACA Bracket, hold the ends of the FW-SP -R wires and slide it and the bracket back inside the FW-ACA to its original location. NO TE: The FW-SP -R slides into a double slot at the bottom of the FW-ACA. The LEDs should be level with the top of the FW-A CA housing.
(6) When the new surge protector board has been secured to the FW-SP -250 cover , reinstall the FW-SP -250 as shown on pages 10-11. (3) Remove the FW-SP -250 (secured by six Phillips screws). (2) Remove the AC Wiring Compartment cover (secured by two Phillips screws).
Wiring and C onnec ting the FLEX ware Surge Pr otec tor With the FW-SP -250 or FW-SP-ACA secur ed, connect all AC and DC wiring as well as any HUB, MA TE, A UX, and BA T TERY TEMP cables.
• Install the various covers in this order with the DCC or Turbo last: (1) DC battery terminals (2) FW-ACA (if used) (3) AC Wiring Compar tment Figur e 16: After wiring, install all covers .
18 FLEX ware ™ Surge P rotector Limited W arranty OutBack P ower Systems , Inc. (“OutBack ”) provides a limit ed warranty (“ Warranty ”) against defects in materials and workmanship for its FLEXware Sur ge Pr otec tor P roducts (“Product”) if installed for use with OutBack FX Series Inverter/Chargers in xed location applications.
19 1. P roof- of-purchase in the f or m of a copy of the original P roduct purchase invoice or r eceipt con rming the Pr oduct model number and serial number ; 2. OutBack issued warranty cer ti cate f or the FX Series I n verter/Charger used with the Pr oduc t; 3.
Surge P rotector Limited W arranty Registra tion 20 Revision 2007-06-20 Surge P rotector Limited W arrant y Registration Complete this form to request a Limited W arranty , and return it to: Outback P ower Systems Inc.
900-0089-01-00 REV A European Sales O c e Barcelona, España (+34) 600-843-845 19009 62nd Avenue NE Arlington, W A USA (+1) 360-435-6030 www.outbackpower .
Ein wichtiger Punkt beim Kauf des Geräts Outback Power Systems FLEXWARE FW-SP-250 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Outback Power Systems FLEXWARE FW-SP-250 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Outback Power Systems FLEXWARE FW-SP-250 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Outback Power Systems FLEXWARE FW-SP-250 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Outback Power Systems FLEXWARE FW-SP-250 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Outback Power Systems FLEXWARE FW-SP-250 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Outback Power Systems FLEXWARE FW-SP-250 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Outback Power Systems FLEXWARE FW-SP-250. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Outback Power Systems FLEXWARE FW-SP-250 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.