www .omega.com e-mail: info@omega.com U ser ’ s Guide OMG-UL TRA-SIO Dual Por t Isolated/Non-Isolated ISA RS-422/485 Adaptor Board Shop online at.
Servicing Nor th America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.
Contents I NTRODUCTION ..........................................................................1 O VERVIEW ................................................................................................ 1 W HAT ’ S I NCLUDED .....................
W HAT IS G ROUND L OOP ? ................................................................... 16 C ABLING R ECOMM ENDATIONS .......................................................... 16 A PPENDIX E - A SYNCHRONOUS C OMMUNICATIONS ................17 A PPENDIX F - S ILK - S CREEN .
Introduction OMG - ULTRA - SIO Page 1 Introduction Overview The OMG - ULTRA - SIO provides the PC with two additional ground isolated RS - 422/485 (P/N 3189) or two non - isolated RS - 422/485 (P/N 3089) serial ports for terminals, modems, printers, etc.
Card Setup OMG - ULTRA - SIO Page 2 Card Setup The OMG - ULTRA - SIO contains several jumper straps that must be set for proper operation. Address Selection Each port on the OMG - ULTRA - SIO occupies eight consecutive I/O locations. A DIP - switch is used to set the base addres s for these locations.
Card Setup OMG - ULTRA - SIO Page 3 IRQ Selection Headers E11 and E12 select the interrupt request for each seria l port. If COM1: is selected, the corresponding jumper must be on the IRQ4 setting. If COM2: is selected, the corresponding jumper must be on IRQ3.
Card Setup OMG - ULTRA - SIO Page 4 Interrupt Modes Header E5 and E6 se lects the interrupt mode for each port. Each port must be set in the correct mode to insure proper operation.
Card Setup OMG - ULTRA - SIO Page 5 Set the jumper to ‘ S ’ if you are using more than one OMG - ULTRA - SIO in a bus or to completely r emove the pull - down resistor for hardware compatibility. Setting the adapter in this configuration when it is not accompanied by a pull - down resistor will prevent the ports from triggering an interrupt .
Card Setup OMG - ULTRA - SIO Page 6 Headers E8 (Port 1) and E10 (Port 2) are used to control the RS - 485 mode functions for the driver circuit. The two selections are ‘RTS’ enable or ‘Auto’ enable. The ‘Auto’ enable feature automatica lly enables/disables the RS - 485 interface.
Card Setup OMG - ULTRA - SIO Page 7 Interface Mode Examples RTS Auto E8 & E10 E3 & E9 Figure 6 - RS - 422 RTS Auto E8 & E10 E3 & E9 Figure 7 - RS - 485 ‘Auto’ Enabled, with ‘No E.
Card Setup OMG - ULTRA - SIO Page 8 Line Termination Typically, each end of the RS - 485 bus must have line terminating resistor s (RS - 422 terminates at the receive end only). A 120 ohm resistor is across each RS - 530/422/485 input in addition to a 1K ohm pull - up/pull - down combination that bias the receiver inputs.
Installation OMG - ULTRA - SIO Page 9 Installation System Installation The OMG - ULTRA - SIO can be installed in any of the PC expansion slots. The OMG - ULTRA - SIO contains several jumper straps for each port which must be set for proper operation. 1.
Technical Description OMG - ULTRA - SIO Page 10 Technical Description The OMG - ULTRA - SIO provides the PC with two additional ground isolated RS - 422/485 (P/N 3189) or two non - isolated RS - 422/485 (P/N 3089) serial ports for terminals, modems, printers, etc.
Specifications OMG - ULTRA - SIO Page 11 Specifications Environmental Specifications Specification Operating Storage Temperature Range 0º to 50º C (32º to 122º F) - 20º to 70º C (- 4º to 158º F) Humidity Range 10 to 90% R.H. Non - Condensing 10 to 90% R.
Appendix A - Troubleshooting OMG - ULTRA - SIO Page 12 Appendix A - Troubleshooting Serial Utility test software is supplied with the adapter and will be used in the troubleshooting procedures. By using this software and following these simple steps, most common problems can be eliminated without the need to call Technical Support.
Appendix A - Troubleshooting OMG - ULTRA - SIO Page 13 8. The following are known I/O conflicts: • The 278 and 378 settings may conflict with your printer I/O adapter.
Appendix B - How To Get Assistance OMG - ULTRA - SIO Page 14 Appendix B - How To Get Assistance Please refer to Troubleshoot ing Guide prior to calling Technical Support. 1. Begin by reading through the Trouble Shooting Guide in Appendix A. If assistance is still needed please see below.
Appendix C – Electrical Interface OMG - ULTRA - SIO Page 15 Appendix C - Electrical Interface RS - 422 The RS - 422 specific ation defines the electrical characteristics of balanced voltage digital interface circuits. RS - 422 is a differential interface that defines voltage levels and driver/receiver electrical specifications.
Appendix D - Ground Loop Phenomenon OMG - ULTRA - SIO Page 16 Appendix D - Ground Loop Phenomenon What is Ground Loop? Ground loop Phenomenon occurs when two (or more) pieces of equipment are connected together with a common ground and a different ground poten tial exists at each location.
Appendix E - Asynchronous Communications OMG - ULTRA - SIO Page 17 Appendix E - Asynchronous Communications Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character.
Appendix F - Silk - Screen OMG - ULTRA - SIO Page 18 Appendix F - Silk - Screen 4.2" 7.35" 3.9".
Appendix G - Compliance Notices OMG - ULTRA - SIO Page 19 Appendix G - Compliance Notices Federal Communications Commission Statement FCC - This equipment has been tested and found to comply w ith the limits for Class A digital device, pursuant to Part 15 of the FCC Rules.
W ARRANTY / DISCLAIMER OME GA ENGINEERING, INC. war rants this unit to be free of defects in materials and workmanship for a period of 1 3 months from date of purc hase. OM E G A ’ s W ARRAN TY adds an additional one (1) month grace period to the normal one (1) year pr oduct warranty to cover handling and shipping time.
M 21 9 6 /0303 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE Thermocouple, RTD & Thermistor Probes.
Ein wichtiger Punkt beim Kauf des Geräts Omega Vehicle Security ISA RS-422 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Omega Vehicle Security ISA RS-422 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Omega Vehicle Security ISA RS-422 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Omega Vehicle Security ISA RS-422 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Omega Vehicle Security ISA RS-422 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Omega Vehicle Security ISA RS-422 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Omega Vehicle Security ISA RS-422 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Omega Vehicle Security ISA RS-422. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Omega Vehicle Security ISA RS-422 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.