RD100B Pr ogrammable Recor der omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info Shop online at U ser ’ s Guide.
Servicing Nor th America: U.S.A.: One Omega Drive, P .O. Box 4047 ISO 9001 Cer tified Stamford, CT 06907-0047 TEL: (203) 359-1660 F AX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 F AX: (514) 856-6886 e-mail: info@omega.
i Foreword Thank you for purchasing the OMEGA RD100B Recorder. This manual describes the functions (excluding the communication functions), installation and wiring procedures, operating procedures, and lists the handling precautions of the RD100B Recorder.
ii Recorder’s Version and Functions Described in This Manual The contents of this manual corresponds to the recorder with version 1.11. RD100B Versions and Functions Reference – Section 7.19 Section 3.4 Section 5.2 Sections 5.5 and 6.13 Communication manual Communication manual Suffix Code – – – – – /C3 /C7 V ersion 1.
iii Safety Precautions The general safety precautions described here must be observed during all phases of operation. Safety Standards and EMC Standards This recorder conforms to IEC safety class I (p.
iv WARNING • Power Supply Ensure that the source voltage matches the voltage of the power supply before turning ON the power. • Protective Grounding Make sure to connect the protective grounding to prevent electric shock before turning ON the power.
v Checking the Contents of the Package Unpack the box and check the contents before operating the recorder. If some of the contents are not correct or missing or if there is physical damage, contact the dealer from which you purchased them. Checking the Model A name plate is affixed to the recorder.
vi Standard Accessories The standard accessories below are supplied with the recorder. Check that all contents are present and undamaged. Z-fold chart paper Ribbon cassette Disposable felt pen Plotter.
vii Removing the Packing Materials Open the door, put your finger on the tab at the lower left of the display, and open the display. Display T ab on the display Open Open Remove all packing materials. • Pen Model Hinge • Dot Model Hinge CAUTION To protect the hinges, do not apply vertical force on the display.
viii How to Use This Manual This user’s guide consists of the following sections. For details on communication functions, see the RD100B/RD1800B Communication Interface User’s Manual on the CD-ROM. Chapter Title and Description 1 Functional Description Describes the functions of the RD100B Recorder.
ix 1 2 3 4 5 6 7 8 9 10 11 12 App Index Conventions Used in This Manual Unit K ........ Denotes 1024. Example: 768 KB (file size) k ........ Denotes 1000. Safety Markings The following markings are used in this manual. Improper handling or use can lead to injury to the user or damage to the instrument.
x Contents Foreword ......................................................................................................................................... i Recorder ’s V ersion and Functions Described in This Manual .............................
xi 1 2 3 4 5 6 7 8 9 10 11 12 App Index 5.4 Changing the Chart Speed ............................................................................................ 5-13 5.5 Setting the Date/T ime .........................................................
xii Contents 9.8 Setting the Partial Expanded Recording ........................................................................ 9-16 9.9 T urning T rend Recording (Dot Model) and Periodic Printout ON/OFF for Each Channel .............................
1-1 Functional Description 1 1.1 Overview of the Recorder The RD100B Recorder (hereafter referred to as the recorder) can be used to assign DC voltage, 1-5V, thermocouple, RTD, and contact or voltage ON/OFF signal to channels for measurement. The measured results are recorded with pens or dots on a chart paper that is fed at a constant speed.
1-2 1.2 Measuring Input Section Input Section Number of Measurement Channels and Scan Interval The recorder samples the input signals on the measurement channels at the scan interval to obtain the measured values.
1-3 Functional Description 1 • Delta Computation The value obtained by subtracting the measured value of another channel (called the reference channel ) from the input value of the channel set to delta computation is used as the measured value of that channel.
1-4 Bias A given value (bias value) is added to the input value and used as the measured value of that channel. Input value Bias value Biased channel Measured value + + <Related Topics> Setting the bias: Section 7.
1-5 Functional Description 1 Noise Elimination from Input Signals Filter and Moving Average This function used to suppress the effects of noise that is riding on the signal. The pen model and dot model are equipped with a filter function and a moving average function, respectively.
1-6 Integration Time of the A/D Converter The recorder uses an A/D converter to convert the sampled analog signal to a digital signal. By setting the integration time of the A/D converter to match the.
1-7 Functional Description 1 1. 3 Alarms This function generates an alarm when the measured data meets a certain condition. The alarm occurrence/release can be recorded on the chart paper. The alarm status can be displayed on the screen. Also, alarm output relays can be used to output contact signals when alarms occur (/A1, /A2, and /A3 options).
1-8 • Delay High Limit Alarm (T) An alarm occurs when the measured value remains above the alarm value for a specified time period (alarm delay period). • Delay Low Limit Alarm (t) An alarm occurs when the measured value remains below the alarm value for a specified time period (alarm delay period).
1-9 Functional Description 1 Alarm Indication The alarm status can be displayed on the screen. For details on the display, see section 1.5. Non-Hold/Hold Operation of the Alarm Indication The alarm indication can be set to operate in the following fashion when the alarm condition is no longer met.
1-10 Reflash Alarm When multiple alarms are assigned to one alarm output relay, this function notifies the occurrence of subsequent alarms after the relay is activated by the first alarm. When subsequent alarms occur, the output relay is released temporarily (approximately 500 ms).
1-11 Functional Description 1 AND/OR Operation of Alarm Output Relays When multiple alarms are assigned to one alarm output relay, the condition for activating the alarm output relay can be selected from the following: • AND: Activated when all assigned alarms are occurring simultaneously.
1-12 Non-Hold/Hold Operation of Alarm Output Relays The alarm output relay can be set to operate in the following fashion when the alarm condition is no longer met. • Turn off the relay output (non-hold). • Hold the relay output until the alarm ACK operation is executed (hold).
1-13 Functional Description 1 1.4 Recording The recorder is capable of recording the measured values with pens or dots (trend recording) as well as various other types of information.
1-14 Trend Recording The measured values are printed within a width of 100 mm. Recording Method (Pen Model) • The measured value is updated every scan interval and continuously recorded. • The recording colors in order from channel 01 are red, green, blue, and violet.
1-15 Functional Description 1 Partial Expanded Recording This function expands a section of the recording range. By default, partial expanded recording is disabled. Compressed Expanded <Related Topics> Setting the partial expanded recording: Section 7.
1-16 Printout The figure below is used to explain the printout contents. The actual printout and font are different from those illustrated in the figure.
1-17 Functional Description 1 Printout Example on the Dot Model Alarm printout Message printout Manual printout Channel printout Periodic printout Scale Buffer overflo w mark Time tick Time tick New chart speed printout Delta computation Alarm Time tick Recording start printout Nov.
1-18 Alarm Printout Alarm information is printed when an alarm occurs or releases. Time of alarm occurrence/release Indicates that there are alarms that are not printed because the alarm printout buffer is full.
1-19 Functional Description 1 • Turning ON/OFF the Periodic Printout Periodic printout can be turn ON/OFF. By default, periodic printout is enabled with the interval synchronized to the chart speed. Also, the measured values that are printed are the instantaneous values.
1-20 Setting Printout List or Setup List can be printed. When setting printout is executed, trend recording stops and restarts when the printout is complete. List contains settings such as the input range and alarm for each channel. Setup List contains settings of basic specifications such as the alarm output relay operation and printout method.
1-21 Functional Description 1 • Printout Example of List on the Dot Model The printout examples may appear differently from the actual printout as a result of functional improvements made on the recorder after this manual was written.
1-22 1.5 Display Displayed Information Main Display The recorder is capable of displaying measured values, alarm information, and so on the VFD (Vacuum Fluorescent Display). Using normal fonts, 17 characters × 2 lines can be displayed. Using large fonts, 11 characters can be displayed.
1-23 Functional Description 1 Several display examples are shown below. For details on the display types, see “Display Function Specifications” in section 12.4. 1 Channel Digital + 1 Bar Graph Display Channel No. Alarm point mark Scale Bar graph Unit Measured value Alarm status Flag Display Scale Flag (the number indicates the channel No.
1-24 1.6 Computation Function (/M1 Option) Computation Function Computing equations can be set up using measured values and other computed values as variables in computation-dedicated channels, and the computation can be executed. The computed result can be recorded.
1-25 Functional Description 1 • Communication Input Data (Pen model: C01 to C08, dot model: C01 to C12) This data type is set using the communication interface (/C7 or /C3 option). Range of values (maximum significant digits is 5): –9.9999E+29 to –1.
1-26 • The Number of Channels Being Trend Recorded and the Fastest Recording Interval The fastest recording interval varies depending on the number of channels being trend recorded. Only display or printout is possible on measurement channels or computation channels that are not trend recorded.
1-27 Functional Description 1 1.7 FAIL/Chart End Detection and Output Function (/F1 Option) FAIL Output When a failure occurs in the CPU of the recorder, a relay contact signal (1 signal) is output. The relay is energized when the CPU is normal and de-energizes when a CPU failure occurs.
1-28 1.8 Remote Control Function (/R1 Option) Specified operations can be carried out by applying remote signals (contact or open collector signals) to the remote control input terminals. There are five remote control input terminals. An action can be assigned to each terminal.
1-29 Functional Description 1 • Computation Start/Stop • Remote input signal: Rising edge signifies start; falling edge signifies stop • Starts/stops the computation. This is valid only on models with the computation function (/M1 option). • If the computation is started, applying a rising edge signal produces no effect.
1-30 1.9 Other Functions Key Lock Key lock is a function that prohibits key operations. When key lock is enabled, pressing keys produces no effect. To release the key lock, a password is entered. Key Lock Items Each of the following keys can be included or excluded from the key lock function.
2-1 Before Using the Recorder 2 2.1 Handling Precautions This section describes the precautions to be taken when using the recorder. Read this section before use. Handling Precautions • Use care when cleaning the recorder, especially any plastic parts.
2-2 2.2 Installation Installation Location Install the recorder indoors in a location that meets the following conditions. See also the normal operating conditions described in section 12.6, “General Specifications.” • Instrument Panel The recorder is designed for panel mounting.
2-3 Before Using the Recorder 2 Installation Procedure The recorder should be mounted on a steel panel of thickness 2 mm to 26 mm. 1. Insert the recorder from the front side of the panel. 2. As shown in the figure below, mount the recorder to the panel using the mounting brackets that come with the package.
2-4 External Dimensions of the Recorder 220 (8.66) (1.08) 27.5 178 (7.01) 136.5 (5.37) +2 0 7.5 9.4 2 to 26 Mounting panel thickness (Dimensions before attaching the mounting bracket) (Dimensions after attaching the mounting bracket) Unit: mm (appro x.
2-5 Before Using the Recorder 2 2.3 Input Signal Wiring General Precautions to Be Taken While Wiring WARNING To prevent the possibility of electric shock when wiring, make sure that the power supply source is turned OFF.
2-6 When using internal reference junction compensation on the thermocouple input, take measures to stabilize the temperature at the input terminal. • Always use the terminal cover. • Do not use thick wires which may cause large heat dissipation (cross sectional area of 0.
2-7 Before Using the Recorder 2 Dot Model +/A –/B b +/A –/B b Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 1 Channel 3 Channel 5 Channel 2 Channel 4 Channel 6 +A –/B b Screw input terminal Clamped input terminal (/H2 option) 1.
2-8 Measuring Input Wiring – – DC voltage 1-5V ON/OFF Extension leadwire DC current Shunt resistor –/B b +/A –/B b +/A –/B b +/A –/B b +/A ++ Thermocouple input Resistance temperature detector input DC voltage input, 1-5V input, and ON/OFF input DC current input Leadwire resistance: 10 Ω max.
2-9 Before Using the Recorder 2 2.4 Optional Terminal Wiring General Precautions to be Taken While Wiring the Input/Output Signal Wires WARNING • To prevent electric shock while wiring, ensure that the power supply source is turned OFF.
2-10 NO C NC NO C NC /A1 NO C NC NO C NC NO C NC NO C NC /A1/F1 /A1/R1 I01 I02 I01 I02 I01 I02 CE FA I L NO C NC NO C NC 12 3 45 C /A1/F1/R1 NO C NC NO C NC NO C NC NO C NC I01 I02 CE FA I L 12 3 45 C.
2-11 Before Using the Recorder 2 Wiring Procedure 1. Turn OFF the recorder and remove the terminal cover. 2. Connect the input signal wires to the terminals. Philips screwdriver Crimp-on lug with insulation sleeves 3. Replace the terminal cover and fasten it with screws.
2-12 2.5 Power Supply Wiring Precautions to Be Taken While Wiring the Power Supply Make sure to follow the warnings below when wiring the power supply. To prevent electric shock and damage to the recorder, observe the following warnings. WARNING • To prevent electric shock when wiring, ensure the main power supply is turned OFF.
2-13 Before Using the Recorder 2 Wiring Procedure The power supply terminals and a protective ground terminal are located on the rear panel. 1. Turn OFF the recorder and open the transparent power terminal cover. Screw for fixing the power terminal cover in place Power terminal block Power terminal cover Open 2.
2-14 2.6 Turning ON/OFF the Power Switch CAUTION Check the following points before turning ON the power switch. • The power cord/wires are connected correctly to the recorder. • The recorder is connected to the correct power supply (see section 2.
3-1 Names of Parts and Run Operations 3 3.1 Names of Parts Front Door Name plate The model name is written on the name plate. P ower switch T urns ON/OFF the power each time the switch is pressed. Chart cassette Holds the chart paper . T ag plate Used to write channel names.
3-2 Display and Key Panel RCD MENU FEED CH UP FUNC MENU DISP 1 CHARACTER RECORD MA TH CHART END ALARM 1 2 3 4 5 6 KEY LOCK ESC/? SHIFT Main display Displays the measured v alues. Also , displays the setup screen when setting functions. Seven keys are a vailable.
3-3 Names of Parts and Run Operations 3 Rear Panel Measuring input terminal block Measuring input terminals Heatsink Dissipates the internal heat. Optional terminal block This is where terminals or ports used by options such as alarm output relays and comm unication interface are installed.
3-4 3.2 Installing or Replacing the Chart Paper CAUTION • Do not install or remove the chart cassette with the chart paper guide open. This may damage the stopper.
3-5 Names of Parts and Run Operations 3 3. Open the chart holder and the chart paper guide. Chart holder This sheet is provided on models with the chart end detection function (/F1 option). Do not remove or bend this sheet. Chart paper guide 4. Load the chart paper.
3-6 6. Replace the chart cassette back into the recorder case. Align the left and right projections of the sprocket section with the guide grooves of the recorder and press the entire chart cassette into the recorder case. The chart cassette is fixed in place with the stoppers.
3-7 Names of Parts and Run Operations 3 3.3 Installing/Replacing Felt Pens or Plotter Pen (Pen Model) CAUTION • Do not press or pinch the felt tip to prevent deformation. • Do not move the penholder left or right by force to protect the driving mechanism.
3-8 When the Pen (Pen Holder) Is at a Position That Is Not Easily Accessible If the pen (pen holder) is at a position that is not easily accessible, carry out the procedure below to move it near the center position. 1. Turn ON the power switch and press the FUNC key.
3-9 Names of Parts and Run Operations 3 3.4 Installing/Replacing the Ribbon Cassette (Dot Model) CAUTION • Improper cassette insertion may cause the color to change or damage the ribbon. • Do not apply upward force to the printer carriage. If you do, the carriage position may be offset, and the recorder may not print correctly.
3-10 7. Install a new ribbon cassette. First, insert the right-hand part and then the left-hand part into the cassette holder. Check that the cassette is properly engaged with the cassette holder tab.
3-11 Names of Parts and Run Operations 3 3.5 Starting/Stopping the Recording This section describes the procedures for starting/stopping the recording and checking the recorded result. Procedure Starting the Recording Press the RCD key to start recording.
3-12 3.6 Switching the Display Screen This section describes the procedure for switching the display screen. To change the displayed content, see chapter 8. Procedure Switching the Display Screen The display screen switches each time the DISP key is pressed.
3-13 Names of Parts and Run Operations 3 3.7 Printing Measured Values (Manual Printout) The measured values of all channels are printed. Procedure Starting the Manual Printout 1. Press the FUNC key. 2. Press the key to select Print out and then press the key.
3-14 3.8 Printing the Recorder Settings This section explains the procedure for printing the recorder settings. There are two sets of settings that can be printed: List and Setup. List: Prints the settings of Setting mode (input range for each channel, etc.
3-15 Names of Parts and Run Operations 3 3.9 Clearing the Alarm Printout Buffer Alarm information waiting to be printed is temporarily stored in the buffer memory. This operation clears all of the alarm information in the buffer. This function can be used to prevent unneeded alarm printouts from being executed.
3-16 3.10 Printing Messages This section explains the procedure for printing the preset character strings. For the procedure of setting the character strings, see section 6.
3-17 Names of Parts and Run Operations 3 3.11 Resetting the Report Data of the Periodic Printout This operation resets the past report data when the recorder is configured to print the report data (the average, the minimum, the maximum, or the sum) of the measured values in periodic printout.
3-18 3.12 Releasing the Alarm Output (Alarm ACK Operation) This operation releases the alarm indication or relay output (/A1, /A2, or /A3 option) when the alarm indication or output relay is set to hold operation. Procedure Releasing the Alarm Output 1.
3-19 Names of Parts and Run Operations 3 * When the key or key is pressed while holding down the SHIFT key, the operation is reversed as when the respective key is pressed by itself. 3.13 Activating/Releasing the Key Lock When the recorder is configured to use the key lock function, this operation activates or releases the key lock.
4-1 Common Operations for Setting Functions and Setup Guide 4 4.1 Run Modes The recorder has three run modes. Operation Mode This mode is used for normal recording operation. The recorder enters this mode when the power is turned ON. The operations that can be carried out in this mode are described in chapter 3.
4-2 4.2 Key Operations This section describes basic operations on the panel keys to change various settings. Functions are set in Setting mode or Basic Setting mode. Entering Setting Mode Hold down the MENU key for 3 seconds. The Setting mode display appears.
4-3 Common Operations for Setting Functions and Setup Guide 4 Changing the Settings Note The comment line shows useful information such as a description of the setup item and the range of selectable values. Read the comment and change the items as necessary.
4-4 Entering Characters Use the key or SHIFT + key to move the cursor. SHIFT key + key key Cursor Unit=ppm CHR:a-z Use the CHARACTER key or SHIFT + CHARACTER key to select the character type. Use the key or SHIFT + key to select a character. You repeat these steps to set the character string.
4-5 Common Operations for Setting Functions and Setup Guide 4 4.3 Menu Structure, Settings, and List of Default Values Operation Menus Using the FUNC Key (Operation Mode) Below are the items that are operated using the FUNC key. Information indicated inside the parentheses is references.
4-6 Pen exchange (Pen Model) Moves the recording pen to a position that is easily accessible for replacement on the pen model. R. exchange (Dot Model) Moves the printer carriage near the center position when replacing the ribbon cassette on the dot model.
4-7 Common Operations for Setting Functions and Setup Guide 4 Menu Structure of Setting Mode Below are the setup items in Setting mode. Information indicated inside the parentheses is references.
4-8 Menu Structure of Basic Setting Mode Below are the setup items in Basic Setting mode. Information indicated inside the parentheses is references. Add function Time print Alarm A/D Burnout CH RJC C.
4-9 Common Operations for Setting Functions and Setup Guide 4 Setup Items in Setting Mode and Their Default Values Items with an asterisk on the left are not displayed in the default condition. To display these items, settings must be changed in Basic Setting mode.
4-10 Setup Item Pen/Dot Selectable Range or Selections Default Value Math > Unit > Unit - 6 characters or less Blank Math > Constant > No. - K01 to K30 K01 Math > Alarm > CH - 0A/0B/.
4-11 Common Operations for Setting Functions and Setup Guide 4 Setup Item Pen/Dot Selectable Range or Selections Default Value Print2 > CH - 01 to 06 01 Print2 > Mode - AVE/MIX/SUM/MIN/MAX/INST .
4-12 Setup Item Pen/Dot Selectable Range or Selections Default Value Math > Color > Color Dot Model Purple/Red/Green/Blue/Brown/Black Purple: 0A/0G Red: 0B/0J Green: 0C/0K Blue: 0D/0M Brown: 0E/.
4-13 Common Operations for Setting Functions and Setup Guide 4 4.4 Function Setup Guide This section explains the settings necessary to use various functions of the recorder. Read the section corresponding to the function you wish to use. Note This section contains all the settings related to each item.
4-14 Alarm functions Item Description Reference Section Alarms for each channel Use Alarm in Setting mode. 5.2 Delay high limit alarm/delay low limit alarm • Alarm type 7.15 Use Personalize > Add function > Alarm delay in Basic Mode and select Use or Not.
4-15 Common Operations for Setting Functions and Setup Guide 4 Item Description Reference Section Periodic printout Measured value Scale Channel number or tag Recording color Mar.31.2004! 15:50* 1 1.000V 2 -1.000V 0.000 2.000 1 V RED 50mm/h_ • Printout interval 7.
4-16 Display functions Item Description Reference Section Display brightness Use Aux > Brightness > Display in Setting mode to set the display brightness. 6.11 Bar graph display mode Use Bar graph in Basic Setting mode to set the bar graph display mode.
4-17 Common Operations for Setting Functions and Setup Guide 4 Item Description Reference Section Periodic printout Computed value Scale Channel number or tag Recording color Mar.31.2004! 15:50* 1 1.000V A -100.00UNIT -200.00 200.00 A UNIT RED 50mm/h_ • Type of computed values to be printed/disable periodic printout 7.
5-1 Frequently Used Setup Operations (Setting Mode) 5 5.1 Setting the Input Range Input range is set for each measurement channel. Set unused channels to Skip. • The input range cannot be changed on models with the computation function (/M1 option) when computation is in progress.
5-2 Description • Selectable Range of Input Range, Span Left, and Span Right The input range, span left, and span right can be set in the range shown below. Span left and span right cannot be set to the same value. DC voltage (Volt) Range Type Selectable Span Range 20 mV –20.
5-3 Frequently Used Setup Operations (Setting Mode) 5 Linear Scaling Select Scale. Set the channel range. Select V olt, TC, RTD, or DI. Select the range type. Set the left span value. Set the right span value. Set the left scale value. Set the right scale value.
5-4 Delta Computation Select Delta. Set the channel range. Set the reference channel. Set the left span value. Set the right span value. The new setting takes effect. First channel Last channel ESC/? Set=Range CH=02-02 Mode=Delta Ref.CH=01 Span_L= -2.
5-5 Frequently Used Setup Operations (Setting Mode) 5 ON/OFF Input Select DI. Set the channel range. Select Cont or Level. Set the left span value. Set the right span value.
5-6 1-5V Input Select 1-5V . Set the channel range. Set the left span value. Set the right span value. Set the left scale value. Set the right scale value. T urn On or Off the low-cut function. The new setting takes effect. First channel (Select the right scale value.
5-7 Frequently Used Setup Operations (Setting Mode) 5 Square Root Computation Select SQRT . Set the channel range. Select the range type of DC voltage. 20 mV , 60 mV , 200 mV , 2 V , 6 V , 20 V , or 50 V Set the left span value. Set the right span value.
5-8 Note • The displayable/printable range of scale values is –19999 to 30000 excluding the decimal. • If the leftmost value of the scale is set to –20000 (excluding the decimal) and the low-cut value is set to –20000, the value when the low-cut function is applied is displayed as “–Over.
5-9 Frequently Used Setup Operations (Setting Mode) 5 5.2 Setting the Alarm The alarm is set for each channel. If you change the input range, set the alarm again. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode. 2. Press the key or SHIFT + key to select Alarm and then press the key.
5-10 Explanation Channel Range The only case when an alarm can be set on multiple channels simultaneously is when the channels are set to the same range type (for example channel 01 and 02 are set to 2 V range). For channels on which scaling is set, the channels must be set to the same range type, same span values, and same scaling values.
5-11 Frequently Used Setup Operations (Setting Mode) 5 Note For channels whose the leftmost value of the scale is set to –20000 (excluding the decimal), the alarm value of –20000 is invalid.
5-12 5.3 Setting the Unit on Scaled Channels Units are set on channels whose input range is set to Scaling, 1-5V, or SQRT. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode. 2. Press the key or SHIFT + key to select Unit and then press the key.
5-13 Frequently Used Setup Operations (Setting Mode) 5 5.4 Changing the Chart Speed This section explains the details of changing the chart speed. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode. 2. Press the key or SHIFT + key to select Chart and then press the key.
5-14 5.5 Setting the Date/Time This section explains the details of setting the date/time. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode. 2. Press the key or SHIFT + key to select Clock and then press the key. 3. Set the date and time and press the key.
6-1 Setup Operations for Convenient Functions (Setting Mode) 6 6.1 Setting the Trend Recording Interval (Dot Model). This section explains the details of setting the trend recording interval (dot printing interval) on the dot model. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode.
6-2 6.2 Setting the Filter (Pen Model) This section explains the details of setting a filter on the measurement channels on the pen model. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode. 2. Press the key or SHIFT + key to select Aux and then press the key.
6-3 Setup Operations for Convenient Functions (Setting Mode) 6 6.3 Setting the Moving Average (Dot Model) This section explains the details of setting the moving average function on measurement channels on the dot model. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode.
6-4 6.4 Setting Recording Zones for Each Channel (Zone Recording) This section explains the details of setting the recording zone for each measurement channel. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode. 2. Press the key or SHIFT + key to select Aux and then press the key.
6-5 Setup Operations for Convenient Functions (Setting Mode) 6 6.5 Setting the Partial Expanded Recording This section explains the details of expanding a section of the recording range. If you change the input range, set the partial expanded recording again.
6-6 6.6 Turning Trend Recording (Dot Model) and Periodic Printout ON/OFF for Each Channel This section explains the details of setting the trend recording and periodic printout for each measurement channel. The following settings can be entered for each channel on the dot model.
6-7 Setup Operations for Convenient Functions (Setting Mode) 6 6.7 Setting Tags on Channels This section explains the details of setting tags to measurement channels. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode. 2. Press the key or SHIFT + key to select Aux and then press the key.
6-8 6.8 Setting the Message String This section explains the details of setting the message strings to be printed on the chart paper. Up to five message strings can be registered. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode.
6-9 Setup Operations for Convenient Functions (Setting Mode) 6 6.9 Setting the Secondary Chart Speed (Remote Control Function, /R1) This section explains the details of setting the secondary chart speed when the chart speed is to be switched using the remote control function (/R1 option).
6-10 6.10 Setting the Alarm Delay Duration This section explains the details of setting the duration of the delay alarm. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode. 2. Press the key or SHIFT + key to select Aux and then press the key.
6-11 Setup Operations for Convenient Functions (Setting Mode) 6 6.11 Setting the Brightness of the Display and Internal Light This section explains the details of setting the brightness of the display and the internal light. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode.
6-12 6.12 Applying a Bias on the Measuring Input Signal This section explains the details of setting a bias on the measuring input signal. If you change the input range, set the bias again. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode.
6-13 Setup Operations for Convenient Functions (Setting Mode) 6 6.13 Setting the Date/Time When Switching between Standard Time and DST This section explains the details of setting the date/time when .
6-14 ESC/? Select Use. Month, day of the week, and time when the DST starts. Month The n th day of the week of the month The n th day of the week of the month Time The new settin g takes effect.
6-15 Setup Operations for Convenient Functions (Setting Mode) 6 Recorders with Version 1.02 or Earlier The following is the setting menu. Select standard time (Winter) or DST (Summer). Select On to set the time to switch between standard time and DST .
7-1 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 7.1 Changing the Auxiliary Alarm Function This section explains the details of setting the alarm system items listed below.
7-2 Select On to set relays I01, I02, and I03 to reflash alarm operation. Select On to set relay I01 to dia gnosis output. Select the range of relays that are to operate using AND logic. Select the relay’ s energized or de-energized operation. Select the relay’ s hold or non-hold operation.
7-3 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 Reflash Turns On/Off the reflash alarm operation of alarm output relays I01, I02, and I03. When set to On, alarm output relays I01, I02, and I03 set to reflash alarm operation, and the operation is fixed to OR, de-energized, and non-hold.
7-4 7.2 Changing the Integration Time of the A/D Converter This section explains the details of setting the integration time of the A/D converter. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).
7-5 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 7.3 Setting the Burnout Detection Function of Thermocouples This section explains the details of setting the burnout detection function of thermocouples to channels set to 1-5V or TC input.
7-6 7.4 Setting the RJC Function on Channels Set to TC Input This section explains the details of setting RJC on channels set to TC input. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).
7-7 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 Explanation RJC Sets the RJC mode. Internal: Uses the RJC function on the recorder. External: Uses an external RJC function. If external is selected, set the compensation voltage.
7-8 7.5 Changing the Channel Recording Color (Dot Model) This section explains the details of changing the trend recording color on the dot model. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).
7-9 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 7.6 Recording by Compensating for the Pen Offset along the Time Axis (Pen Model) This section explains the details of setting the compensation for the pen offset along the time axis (pen model).
7-10 7.7 Turning Printouts ON/OFF. This section explains the details of turning ON/OFF the printouts of various items. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).
7-11 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 Applying the Changes and Returning to Operation Mode Press the key or SHIFT + key to select End and then press the key. Press the key to select Store and then press the key. The changes are applied, and the screen returns to Operation mode.
7-12 7.8 Setting the Periodic Printout Interval and the Type of Measured Values to Be Printed This section explains the details of setting the periodic printout interval and the type of measured values to be printed.
7-13 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 Types of Report Data to Be Printed Changing the Settings 1. Hold down the MENU key for 3 seconds to enter Setting mode. 2. Hold down the and keys simultaneously for 3 seconds to enter Basic Setting mode.
7-14 Explanation Periodic Printout Interval Periodic Select the periodic printout interval mode. Auto: Automatically sets the printout interval in sync with the chart speed. Manual: Set the printout interval manually. Ref. Time Sets the reference time for determining the times for executing the periodic printout.
7-15 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 7.9 Setting the Bar Graph Display Mode This section explains the details of setting the bar graph display mode. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).
7-16 7.10 Setting the Key Lock Function This section explains the details of setting the keys that can be locked and the password for releasing the key lock. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).
7-17 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 ESC/? Set the passw ord for releasing the ke y lock. Select whether to use the key loc k function. Select Lock to appl y the key lock function to the RCD key . Select Lock to appl y the key lock function to the FEED key .
7-18 Applying the Changes and Returning to Operation Mode Press the key or SHIFT + key to select End and then press the key. Press the key to select Store and then press the key.
7-19 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 7.11 Enabling the Moving Average Function (Dot Model) This section explains the details of enabling/disabling the moving average function on the dot model.
7-20 7.12 Enabling the Filter Function (Pen Model) This section explains details of enabling/disabling the input filter function on the pen model. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).
7-21 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 7.13 Enabling the Partial Expanded Recording Function This section explains the details of enabling/disabling the partial expanded recording function.
7-22 7.14 Changing the Display/Recording Language This section explains the details of changing the display/recording language. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).
7-23 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 7.15 Enabling the Bias Function, Low-Cut Function, and Alarm Delay Function This section explains the details of enabling/disabling the bias function, low-cut function, and the alarm delay function.
7-24 Explanation Bias Enables/Disables the bias function. Use: Enables the setting of the bias value in Setting mode. Not: The Bias item does not appear in Setting mode. SQRT low-cut Enables/Disables the square root low-cut function. Use: Enables the setting of the low-cut function when a channel is set to square root computation in Setting mode.
7-25 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 7.16 Changing the Time Printout Format This section explains the details of changing the time printout format of alarm printout, message printout, recording start printout, and new chart speed printout.
7-26 Explanation Alarms Sets the time printout format of the alarm printout. HH:MM: Hour:Minute HH:MM:SS: Hour:Minute:Second M/D H:M: Month Day Hour:Minute M/D H:M:S: Month Day Hour:Minute:Second YMD H:M:S: Month Day Year Hour:Minute:Second Message Sets the time printout format of the message printout.
7-27 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 7.17 Initializing the Settings This section explains the details of initializing the recorder settings to their factory default. Be careful, because all settings except the date/time setting in the recorder will be initialized.
7-28 7.18 Assigning Functions to the Remote Control Input Terminals (/R1 Option) This section explains the details of assigning functions to the input terminals of the remote control function. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).
7-29 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 Explanation Remote No. The remote control terminal numbers are from 1 to 5. Function to Be Assigned Record On/Off: Starts/stops recording. Alarm ACK: Executes alarm output release.
7-30 7.19 Changing the Printout/Display Format of the Date This section explains how to change the printout/display format of the year, month, and day. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).
7-31 Setup Operations for Changing/Adding Functions (Basic Setting Mode) 7 7.20 Changing the Temperature Unit This section explains the details of changing the temperature unit on the temperature measurement channels.
8-1 Setup Operations for Changing the Displayed Contents 8 8.1 Key Operations for Changing the Displayed Information Displaying the Data Display Setup Screen Hold the MENU 1 key for 3 seconds to show the data display setup screen. P ower ON Data display setup mode Operation mode MENU 1 Hold down or 3 s to switc h.
8-2 Data Display Setup Menu This menu is used to assign display types to screen 01 to 15. The indicates a display type. The items to set for each type are shown to the right of the display type.
8-3 Setup Operations for Changing the Displayed Contents 8 8.2 Changing the Displayed Information This section explains the details of registering display types to screens 01 to 15. As an example, the procedure of setting 1-channel digital display is explained below.
9-1 Operations Related to the Computation Function (/M1 Option) 9 9.1 Starting/Stopping/Resetting the Computation This section explains the details of starting/stopping the computation and resetting the computed values of computation channels. Procedure Starting the Computation 1.
9-2 9.2 Setting the Computing Equation The computing equation cannot be entered when the computation is in progress. If you change the computing equation or the recording span, set the alarm and the partial expanded recording again. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode.
9-3 Operations Related to the Computation Function (/M1 Option) 9 Each time you press the CHARACTER key the display changes as shown below. Pressing the key or SHIFT + key switches the character within the selected character type and displays the character at the cursor position.
9-4 Explanation Computing Equation Follow the rules below when writing computing equations. • Use up to 120 characters to write equations. • The precedence of computing terms can be specified using parentheses. • Specify the channels in the equation using 2-digit channel numbers.
9-5 Operations Related to the Computation Function (/M1 Option) 9 • Status of the Remote Control Input Terminal (D01 to D05, /R1 option) The status of the remote control input signal (1 or 0) can be used in the computation.
9-6 Relational Computation The data that can be used in equations are measured values, computed values, constants, communication input data, and remote control input terminal status. You can specify a computing equation that performs relational computation on a computing element.
9-7 Operations Related to the Computation Function (/M1 Option) 9 OR Logical sum (Syntax) e1ORe2 (Condition) If the two data values e1 and e2 are both zeroes, the computed result is “0.
9-8 TLOG Computation Only measured values and computed values can be used in TLOG computation. In the explanation below, e1 is used to represent a measurement or computation channel. You cannot specify an equation that contains a computing element inside e1.
9-9 Operations Related to the Computation Function (/M1 Option) 9 9.3 Setting the Unit This section explains the details of setting the unit on computation channels. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode. 2. Press the key or SHIFT + key to select Math and then press the key.
9-10 9.4 Setting the Constants Used in Equations This section explains the details of setting constants to be used in computing equations. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode. 2. Press the key or SHIFT + key to select Math and then press the key.
9-11 Operations Related to the Computation Function (/M1 Option) 9 9.5 Setting the Alarm This section explains the details of setting alarms for each computation channel. If you change the computing equation or the recording span, set the alarm again.
9-12 Explanation Alarm Type Symbol Name H High limit alarm L Low limit alarm T Delay high limit alarm* t Delay low limit alarm* * Selectable only when the alarm delay function is enabled. See section 7.15. If delay high limit alarm or delay low limit alarm is specified, set the alarm delay time.
9-13 Operations Related to the Computation Function (/M1 Option) 9 9.6 Specifying the Timer Used in Statistical Calculations (TLOG) On channels that perform statistical calculation (TLOG), the timer for determining the interval is specified. The sum scale is also specified when using statistical calculation.
9-14 Explanation Timer No. There are three timers. Periodic: The timer for determining the periodic printout interval. The computed result is printed every interval, and the computed TLOG value is reset. 1: The timer of timer No. 1. Specify whether the computed value is printed every interval and whether to reset the computed value.
9-15 Operations Related to the Computation Function (/M1 Option) 9 9.7 Setting Recording Zones for Each Channel (Zone Recording) This section explains the details of setting the recording zone for each computation channel. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode.
9-16 9.8 Setting the Partial Expanded Recording This section explains the details of expanding a section of the recording range. If you change the computing equation or the recording span, set the partial expanded recording again. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode.
9-17 Operations Related to the Computation Function (/M1 Option) 9 9.9 Turning Trend Recording (Dot Model) and Periodic Printout ON/OFF for Each Channel This section explains the details of setting the trend recording and periodic printout for each computation channel.
9-18 9.10 Setting Tags on Channels This section explains the details of setting the tag on computation channels. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode. 2. Press the key or SHIFT + key to select Math and then press the key.
9-19 Operations Related to the Computation Function (/M1 Option) 9 9.11 Setting the Alarm Delay Duration This section explains the details of setting the duration of the delay high limit and delay low limit alarms. Procedure 1. Hold down the MENU key for 3 seconds to enter Setting mode.
9-20 9.12 Setting the Timer Used in TLOG Computation and Periodic Printout This section explains the details of setting the timer used in TLOG computation and periodic printout. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).
9-21 Operations Related to the Computation Function (/M1 Option) 9 Applying the Changes and Returning to Operation Mode Press the key or SHIFT + key to select End and then press the key. Press the key to select Store and then press the key. The changes are applied, and the screen returns to Operation mode.
9-22 Reset Selects whether to reset the TLOG computed value at each interval. The figure below illustrates the reset operation for sum computation (TLOG.SUM). Example: TLOG.SUM computation 12 3 Reset Reset Reset Reset: On Timer timeout Reset: Off When reset is ON, the sum value is calculated over each interval.
9-23 Operations Related to the Computation Function (/M1 Option) 9 9.13 Changing the Channel Recording Color (Dot Model) This section explains the details of changing the recording colors of computation channels.
9-24 9.14 Changing the Channel Assignments of Recording Pens (Pen Model) Measurement channels and computation channels can be arbitrarily assigned to recording pens. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).
9-25 Operations Related to the Computation Function (/M1 Option) 9 9.15 Changing the Type of Report Data Printed in Periodic Printout This section explains the details of selecting the type of compute.
9-26 Explanation Mode Sets the type of report data to be printed. AVE: Prints the average value over the interval. MIX: Prints the minimum, maximum, and average values over the interval. SUM: Prints the sum value over the interval. If SUM is selected, set the sum scale.
9-27 Operations Related to the Computation Function (/M1 Option) 9 9.16 Setting the Bar Graph Display Mode This section explains the details of setting the bar graph display mode. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).
9-28 9.17 Setting the Procedure Taken When the Computed Result Is in Error This section explains the details of setting the procedure taken when the computed result is in error. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).
9-29 Operations Related to the Computation Function (/M1 Option) 9 Explanation Error Specifies how to display or print the computed result when computation errors occur. +Over: Set to +over. Displayed/Printed as “+Over.” –Over: Set to –over. Displayed/Printed as “–Over.
10-1 Troubleshooting 10 10.1 A List of Error Messages There are cases in which error codes and messages are displayed on the screen during operation. The error messages and their description are listed below. Setting Errors Code Message Explanation/Countermeasures 1 System error.
10-2 Code Message Explanation/Countermeasures 72 MATH channel is turned off – 81 All space or ‘quit’ string cannot be specified. – 86 The key-lock release password is incorrect. Enter the correct password. 87 This key is locked. – 91 Password is incorrect.
10-3 Troubleshooting 10 Code Message Explanation/Countermeasures 400 Input username. – 401 Input password. – 402 Select username from ‘admin’ or ‘user’. If the recorder is configured not to use the user name and password, use user names ‘admin’ or ‘user’.
10-4 10.2 Troubleshooting Flow Charts Follow the flow charts to correct the problem. Is the power supply connected properl y? Is the power supplied properl y? NO NO NO YES YES YES Nothing works (pen and chart paper do not move). Is the power switc h turned ON? Does the switch work pr operly? Connect properl y .
10-5 Troubleshooting 10 NO NO NO YES YES YES Is the input wiring correct? • Attach the input terminal cover properly. • Protect the input terminal from wind or fans.
10-6 Is the input free of noise? NO YES • Separate the input and communication wiring fr om the noise source. • Ground the recor der properly . • Use shielded cables for input and communication wiring. • Insert an isolation transformer into the power line.
11-1 Maintenance 11 11.1 Periodic Inspection Check the operation periodically to keep the recorder in good working order. Perform the following checks and replace worn parts as needed. • Is the indication and recording functioning properly? If not, see chapter 10.
11-2 11.2 Cleaning the Recorder CAUTION • When cleaning, be sure not to scratch the flexible printed circuit board of the plotter carriage. • Do not apply lubricating oil to the shaft. Pen Model To maintain smooth operation, it is recommended that the plotter carriage shaft be cleaned once a year.
11-3 Maintenance 11 11.3 Replacing the Internal Light LED If the brightness of the internal light degrades with time, replace the LED. For the replacement parts, see section 11.7. CAUTION • The LED is connected to the internal circuitry through the flexible printed circuit board.
11-4 11.4 Calibrating the Recorder Calibrate the measured value against the input. It is recommended that the recorder be calibrated once a year to assure its measurement accuracy. For details regarding calibration, contact OMEGA. Required Instruments A calibration instrument with appropriate resolution l˜ required for calibrating the recorder.
11-5 Maintenance 11 Temperature Measurement When Using an RTD Decade resistance box The resistance of three lead wires must be equal. +/A /b Input terminals − /B Temperature Measurement When Using a.
11-6 11.5 Adjusting the Pen Position (Pen Model) This section explains the details of adjusting the pen position on the chart paper. It is recommended that the pen be adjusted once a year to assure its recording accuracy. Note Pen position is adjusted under standard operating conditions when the recorder is shipped from the factory.
11-7 Maintenance 11 11.6 Adjusting the Dot Printing Position (Dot Model) This section explains the details of adjusting the dot printing position on the chart paper. It is recommended that the position be adjusted once a year to assure its recording accuracy.
11-8 7. Press the ESC key to finish the adjustment. The screen returns to the Basic=P_Adj screen. Select Zero or Full. Change the value to adjust the pen position.
11-9 Maintenance 11 11.7 Recommended Replacement Periods for Worn Parts To preserve the reliability of the recorder and to use the recorder in good condition for an extended time, it is recommended that periodic replacements be made on parts. The table below shows the recommended replacement period for expendable parts.
11-10 Dot Model Note 33 days 3 months B9962EJ CARRIAGE ASSY 5 years Item Replacement Period Part Name Part No. Ribbon feed motor Z-fold chart paper CHART RD100-ZFP-10 When used at 20 mm/h Ribbon shift.
12-1 Specifications 12 12.1 Input Specifications Number of Inputs and Scan Interval on the Pen Model Item Specifications Number of inputs 1, 2, 3, or 4 Scan interval 125 ms Number of Inputs and Scan Interval on the Dot Model Item Specifications Number of inputs 6 Scan interval 1 s (when the integration time of the A/D converter is 20 ms or 16.
12-2 Item Specifications Input type Floating unbalanced input. Isolation between channels (except, b terminal is shared for RTD input). Burnout Detection of TC Can be set for each channel. Upscale/Downscale switchable. Input Type Operating Conditions TC input 2 k Ω or less: normal, 10 M Ω or more: burnout, detection current: approx.
12-3 Specifications 12 12.2 Alarm Function Specifications Item Specifications Number of alarms Up to four alarms (level) for each measurement channels.
12-4 12.3 Recording Function Specifications Trend Recording (Pen Model) Item Specifications Recording pen Disposable felt pen Step response time Approx. 1 s (using the IEC61143 measurement method) Number of pens Up to 4 Recording color Pen 1: Red, pen 2: Green, pen 3: Blue, pen 4: Violet Trend recording Updates the data at the scan interval.
12-5 Specifications 12 Printouts (Pen Model) Item Specifications Recording pen (color) Plotter pen (purple) Alarm printout Prints alarm occurrence/release. Printout contents Occurrence ( )/release ( ) marks, channel No. or tag, alarm type, alarm level, time, printout buffer overflow mark.
12-6 Printout (Dot Model) Item Specifications Recording Dot printing. Channel printout Prints the channel number beside the trend recording every approx. 25 mm of chart paper. Channel printout ON/OFF selectable. Alarm printout Prints alarm occurrence/release.
12-7 Specifications 12 12.4 Display Function Specifications Display and Displayed Contents This section explains the specifications of the display functions of measurement channels and computation channels (/M1 option) . Display examples are illustrations used to explain the displayed contents and differ in appearance from the actual displays.
12-8 Item Specifications Display type specifications Digital display Measured value or computed value • DC voltage input: Displays values between “the min. measurable value – 5% of the span of the measurable range” and “the max. measurable value + 5% of the span of the measurable range” of the range (example: –2.
12-9 Specifications 12 Item Specifications Bar graph display Displays the measured value on a bar graph. Relationship between the digital display and bar graph Displays the same channel on the digital display and bar graph.
12-10 Name Display Example Description 1-channel digital display 2-channel digital display 4-channel digital display 6-channel digital display (Dot model) 4-channel bar graph display (Pen model) 1-cha.
12-11 Specifications 12 Name Display Example Description Ta g Alarm Measured value Unit Measurement channel Measurement channel Measurement channel Computation channel Measurement channel Computation .
12-12 Name Display Example Description Multiple display (Different screens assigned to the top and bottom sections) Chart speed 1-channel digital display 2-channel digital display Channel ID alarm sta.
12-13 Specifications 12 12.5 Specifications of Optional Functions Alarm Output Relay (/A1, /A2, and /A3) Item Specifications Operation Outputs relay contact signals from the dedicated terminals on the rear panel when alarms occur. Number of outputs 2 outputs (/A1), 4 outputs (/A2), 6 outputs (/A3) Relay contact rating 250 VDC/0.
12-14 FAIL/Chart End Detection and Output (/F1) Item Specifications FAIL output Relay output on CPU error Relay operation Energized during normal operation and de-energized on CPU error. Non-hold operation. Chart end detection output Stops recording and outputs a relay signal when the remaining amount of chart paper is approx.
12-15 Specifications 12 Alarms Number of alarms Up to four alarms (level) for each measurement channels. Alarm types High limit (H), low limit (L), delay high limit (T), delay low limit (t).
12-16 Item Specifications Measurement and recording accuracy Input T ype Measurement Accuracy Recording Accuracy PR40-20 0 to 450 ° C Not warranted 450 to 750 ° C ± (0.9% of rdg + 3.2 ° C) 750 to 1 100 ° C ± (0.9% of rdg + 1.3 ° C) 1 100 to 1900 ° C ± (0.
12-17 Specifications 12 12.6 General Specifications Construction Item Specifications Mounting Flush panel mounting (on a vertical plane) Mounting angle Inclined backward up to 30 degrees from a horizontal plane.
12-18 Isolation Item Specifications Insulation resistance Each terminal to ground terminal: 20 M Ω or more (at 500 VDC) Dielectric strength Power supply to ground terminal: 1500 VAC (50/60 Hz), 1 mi.
12-19 Specifications 12 Standard Performance Item Specifications Measurement and recording accuracy The following specifications apply to operation of the recorder under standard operation conditions:.
12-20 Item Specifications Reference junction compensation accuracy Above 0 ° C with input terminal temperature balanced (60 minutes after power on) Type R, S, B, W, WRe: ± 1.
12-21 Specifications 12 12.7 Dimensional Drawings 220 (8.66) (1.08) 27.5 178 (7.01) 136.5 (5.37) +2 0 7.5 9.4 2 to 26 Mounting panel thickness (Dimensions before attaching the mounting bracket) (Dimensions after attaching the mounting bracket) Unit: mm (appro x.
App-1 Periodic Printout and Printout Using the TLOG Timer (/M1 Option) App Appendix Appendix 1 Periodic Printout and Printout Using the TLOG Timer (/M1 Option) Periodic Printout This section explains the contents of the periodic printout. The periodic printout contents vary between the pen model and dot model.
App-2 • Scale Prints the leftmost and rightmost values of the recording span and the channel number or tag for channels that have scale printout specified. The scale is printed for one channel at each periodic printout. The channel whose scale is printed changes in ascending order.
App-3 Periodic Printout and Printout Using the TLOG Timer (/M1 Option) App Dot Model Instantaneous Mode Prints the letter “d” for channels set to delta computation. Alarm Unit Channel No. or tag Measured value Date Time Channel data Computation channel Scale Chart speed Time tick Mar.
App-4 Printout Using the TLOG Timer (/M1 Option) Prints the computed values of computation channels for each interval determined by the TLOG timer. Pen Model Offset compensation mark/event Alarm Unit Channel No. or tag Measured value Date Time Channel data Scale Recording color Timer Mar.
App-5 Periodic Printout and Printout Using the TLOG Timer (/M1 Option) App Special Cases This section explains the operation of the periodic printout report (statistical calculation) and the TLOG computation for special cases.
Index-1 Index Index Index chart speed ............................................................. 1-14, 5-13 cleaning ............................................................................. 11-2 clearing alarm information .....................
Index-2 F Page FAIL output ....................................................................... 1-27 fastest recording interval ................................................... 1-26 feeding the chart paper .......................................
Index-3 Index Index R Page range type ........................................................................... 1-2 rear panel ............................................................................ 3-3 recorder ................................
Index-4.
W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months fr om date of pur cha se. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
M4231/0805 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE M U Thermocouple, R TD & Thermistor Probes, Connectors.
Ein wichtiger Punkt beim Kauf des Geräts Omega RD100B (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Omega RD100B noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Omega RD100B - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Omega RD100B reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Omega RD100B erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Omega RD100B besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Omega RD100B verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Omega RD100B. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Omega RD100B gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.