LDP-124 AND LDP-144 SERIES FOR TEMPERATURE http://www .omega.com e-mail: info @ omega.com User's Guide.
OMEGAnet On-Line Service Internet e-mail http://www.omega.com info@omega.com Servicing North America: USA : One Omega drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel : (203) 359-1660 Fax : (203) 359 7700 e-mail : info@omega.
Page : 2 CONTENTS DESCRIPTION SECTION PAGE =========================================================================== IMPORTANT SAFETY CONSIDERATIONS 13 UNPACKING AND INSPECTION 24 MAIN FEATURES 35 M.
Page : 3 INSTALLATION PRECAUTIONS.- The installation and the future use of this unit must be done by suitable qualified per- sonnel. The unit has not AC (mains) switch, it will be in op- eration as soon as power is connected. The installation must incorporate an external main switch.
Page : 4 2.- UNP ACKING AND INSPECTION It is advisable to do a detailed reading of this Manual before mounting the instrument. This Operator's Manual contains all the technical specifications : electricals as well as mechanics, both necessary to do a correct installation and also a good use of the instrument.
Page : 5 3.- MAIN FEA TURES On this paragraph is detailed the main features for every one of the series which are the following : Instruments of four digits plus polarity (only minus) to show temperature using the signal generated by sensors type RTD (PT-100 (0.
Page : 6 4.- MODELS LDP-1X4-MX Temperature indicator for RTD sensor type PT-100 (100 Ω at 0 °C Alpha = 0.00385). This model uses the 3-wire measurement, which compensates thelead wire resistance. However 2-wire sensors can be used too. See wiring connections.
Page : 7 D C B A 5.- GENERAL SPECIFICA TIONS DISPLAY TYPE . . . . . . . . . . . . . . . . . . . . . . . . . 4 digits, 7 segments, red or green LED. HEIGHT DIGIT . . . . . . . . . . . . . . . . . . 5 7 mm. (2.3") or 100 mm. (4"). RANGE . . . .
Page : 8 3-wires connection. 2-wires connection. Do not forget to link terminal A to terminal C. D C B A D C B A Signal input connector. Thermocouple + _ PT-100 PT-100 8.- WIRING 8.1.- POWER SUPPLY, RECOMMENDED WIRING Power switch POWER SUPPLY 115 Vac (230 Vac Optional).
Page : 9 9.- TEMPERA TURE RANGES ± 0.5 % C B A PT1. ZERO adjust COMPONENTS SIDE PT2. SPAN adjust. The control board contains the Analog/Digital con- verter, the Signal Conditioner and other compo- nents.
Page : 10 1 1.- ADJUSTMENT AND CALIBRA TION PROCEDURE 11.1.- RTD MODEL S A decade box or RTD simulator is required. 1.- Check that the instrument is not powered. 2.- Connect the RTD simulator or decade box to the signal input connector (See paragraph 8.
Page : 11 4 5 3 2 1 12.- INST ALLA TION 1.- Prepare a panel cut-out with the dimensions indicated on paragraph 13. 2.- Slide the instrument (1) into the cut-out. 3.- Slide the two fixation pieces (3) with T shape by both lateral sides of the instrument, such as it is shown on the drawing below.
W ARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! TEMPERA TURE ; Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies ; Wire: Thermoco.
Ein wichtiger Punkt beim Kauf des Geräts Omega LDP1XX-21 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Omega LDP1XX-21 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Omega LDP1XX-21 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Omega LDP1XX-21 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Omega LDP1XX-21 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Omega LDP1XX-21 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Omega LDP1XX-21 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Omega LDP1XX-21. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Omega LDP1XX-21 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.