U ser ’ s Guide IP710 SERIES I/P Conver ters Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info.
Servicing Nor th America: USA: One Omega Drive, P .O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 F AX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 F AX: (514) 856-6886 e-mail: info@omega.
W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months fro m d ate of pu rcha se. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
Page 1 1 .00 25.4 2.94 74.7 1 2 3.69 93.7 2.18 55.4 .125 3.17 .500 12.7 1.80 45.7 1.30 33.0 1.50 38.1 Mounting Holes #10 –32 UNF –2B X 3/8 Deep 2 Places 22 GA. wire leads approx. 18" long pos, neg, grd In and out ports 1/4 –20 NPT 4 places 1.
DANGER, W ARNING, CAUTION and NOTE statements R efers to conditions or hazards which could result in serious personal injury or death. Refers to conditions or hazards which could result in personal injury . Refers to conditions or hazards which could result in equipment or proper ty damage.
1. DESCRIPTION and INST ALLA TION 1.1 Description 1.1.1 The Omega IP710 converts a curr ent input signal to a linearly proportional pneumatic output pressur e. This unit utilizes a closed loop pressur e feedback system that closely controls output and compensates for vibration, mounting angle, temperature and supply pr essure variations.
Figure 3 - DIN 43650 Connector DIN Rail mounting kit IP610-DM 1.4 Pneumatic Connections 1.4.1 Clean all pipe lines to remove dirt and scale befor e installation. 1.4.2 Supply air must be filtered to 40 micr ons and free of moistur e and lubricants. 1.
1.6 Factory Mutual Research Corporation (FM) and Canadian Standards association (CSA) Factory Mutual and Canadian Standards Association I.S. Installation Drawing Notes: 1. Control equipment connected to the Associated Apparatus must not use or generate mor e than 250 V rms or Vdc.
2. OPERA TION 2.1 Calibration 2.1.1 All units ar e shipped from the factory calibrated, direct acting. 2 .1.2 If the user r equires a differ ent mode of operation (i.e. reverse acting, split range) it is necessary to r eposition inter- n al electrical switches as indicated below .
2.3 Reverse Acting Calibration 2.3.1 When calibrated to operate in the r everse acting mode the minimum input signal produces the maximum output pressur e and increasing the input signal r esults in decreasing the output pressur e. Setting the unit to operate in the reverse acting mode is accomplished by positioning internal electrical switches.
Page 8 3. MAINTENANCE AND REP AIRS U nder normal circumstances, no maintenance should be required. 3.1 Cleaning 3.1.1 If clean, dry air is not used the orifice can become blocked. T o clear , first tur n off supply air , then remove the screw located under the zer o adjustment.
M-4063/ 0 3 0 7 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE M U Thermocouple, R TD & Thermistor Probes,.
Ein wichtiger Punkt beim Kauf des Geräts Omega IP710 SERIES (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Omega IP710 SERIES noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Omega IP710 SERIES - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Omega IP710 SERIES reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Omega IP710 SERIES erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Omega IP710 SERIES besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Omega IP710 SERIES verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Omega IP710 SERIES. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Omega IP710 SERIES gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.