Benutzeranleitung / Produktwartung CV352 des Produzenten NuTone
Zur Seite of 12
BUIL T -IN CENTRAL CLEANING SYSTEM MODEL: CV -352 GENERAL INFORMATION .............. 2 LAYOUT AND PLANNING ............... 2 Examples ........................................2 Locating the Power Unit ..................3 Locating the Wall Inlets ......
2 GENERAL INFORMA TION LA YOUT AND PLANNING EXAMPLES The Nu T one Central Cleaning System consists of a Central Power Unit, PVC Tubing, PVC Fittings, automatic switch operated Wall Inlets, a flexible hose and various cleaning attachments. As an aid in planning the installation, look at the following examples.
3 FIGURE 3 THE SPLIT -LEVEL HOUSE Like the two-story house, the split level installation commonly calls for a two-level trunk line. Here, the power unit is located in the garage. The intake tubing runs exposed up the garage wall and into the ground level section's attic.
4 INST ALLA TION IN NEW CONSTRUCTION W ALL INLET ROUGH-IN 1. Once the locations for wall inlets have been determined, mount all inlet brackets. 2. To locate bracket on wall stud, measure approximately 18" up from finished floor level. (Height may vary according to individual preference.
5 FIGURE 7 INCLUDE FITTING RECESS IN MEASUREMENT TUBING MEASUREMENT PVC TUBING FIT TING FIT TING 3 / 4 " 3 / 4 " FIGURE 8 FIGURE 9 FIGURE 10 FIGURE 11 FIGURE 12 TUBING INST ALLA TION 1. Cut a 2 1 ⁄ 2 " diameter hole in sole plate, header or stud directly in line with opening of inlet bracket fitting.
6 FIGURE 15 FIGURE 16 MODEL 365 DOUBLE FLANGED TEE W ALL INLET MOUNTING BRACKET SHORTEN W ALL FIGURE 13 FIGURE 14 W ALL INLET INST ALLA TION MODEL 360 W ALL INLET(361 Rough in) 1. Once the walls have been finished, install the wall inlets. 2. Remove the cardboard plaster guard.
DIMENSIONAL CHART MODEL DIMENSION CV-352 A 27" B7 3 ⁄ 4 " C6 1 ⁄ 2 " D1 3 5 ⁄ 8 " 7 POWER UNIT INST ALLA TION MOUNTING See Figure 18. 1. Locate the power unit within six feet of a grounded electrical outlet. 2. Drill 3 ⁄ 16 " diameter pilot holes for the two (2) mounting screws in a wall stud or strong support.
8 INST ALLA TION IN EXISTING CONSTRUCTION LA YOUT AND PLANNING The general layout and planning and the component locations are the same for existing construction.
9 4. Be sure tubing hole is centered in sole plate and directly in line with proposed wall inlet cutout. NOTE: If 330 wall inlet is being used refer to Model 330 Wall Inlet Installation on next page. 5. If area is clear, cut an inlet opening in the wall approximately 18" above the floor.
10 MOUNTING PLA TE MOUNTING HOLE (2) ELBOW FIGURE 32 MOUNTING PLA TE INLET FIGURE 33 1. Make cutout according to dimensions in Figure 30. 2. Refer to Figure 31. Break off nail plate at scored line. 3. Refer to Figure 32. Glue elbow to mounting plate, place assembly into cutout, and attach elbow to tubing inside the wall.
11 FLOOR SUB-FLOOR 2 9 / 16 " 3 1 / 16 " INLET EXTENSION FLOOR INLET FRAME MOUNTING BRACKET SEAL FLANGED FITTING FIGURE 36 CUT TO LENGTH EXTENSION SLEEVE FLANGED FITTING MOUNTING BRACKET FLA.
Product specifications subject to change without notice. Printed in U.S.A., Rev. 4/01, Part No. 84912 T wo Y ear Limited W arranty WARRANTY OWNER: NuTone warrants to the original consumer purchaser of.
Ein wichtiger Punkt beim Kauf des Geräts NuTone CV352 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie NuTone CV352 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für NuTone CV352 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von NuTone CV352 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über NuTone CV352 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon NuTone CV352 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von NuTone CV352 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit NuTone CV352. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei NuTone CV352 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.