Benutzeranleitung / Produktwartung USB-6501 OEM des Produzenten National Instruments
Zur Seite of 13
USER GUIDE USB-6501 OEM This user guide describes how to use the National Instruments USB-6501 OEM data acquisition (DA Q) de vice. The NI USB-6501 OEM is a full-speed USB 2.0 de vice that provides 24 DIO channels and a 32-bit counter . Dimensional Drawings Figure 1 shows a top view of the US B-6501 OEM.
USB-6501 OEM U ser Guide 2 ni.com Figure 2. USB-6501 OEM Dimensions (Front and Rear Views) Block Diagram Figure 3 shows key functional compo nents of the USB-6501 OEM device. Figure 3. Device Bl ock Diagram Refer to the Safety G uidelines section of this document for im portant safety information.
© National Instruments Corporatio n 3 USB-6501 OEM User Guide I/O Connector and Cable Use any 34-pin female IDC (ribbon) cable to connect to th e IDC connector on the USB-6501 OEM device. Table 1 lists the pin assignments and sign al names for the IDC connector.
USB-6501 OEM U ser Guide 4 ni.com Signal Descriptions Table 2 describes the signals available on the I/O connectors. Digital I/O The USB-6501 OEM has 24 single-ended digital lines, P0.<0..7>, P1.<0..7>, and P2.<0.. 7>, which com p rise the three DIO ports.
© National Instruments Corporatio n 5 USB-6501 OEM User Guide Figure 4. Example of Connecting Extern al User -Provided Resistor Complete the following steps to determine the v alue of the user-provided pull-up resistor: 1. Place an ammeter in se ries with the load.
USB-6501 OEM U ser Guide 6 ni.com Figure 5. Example of Connecting a Load Caution Exceeding the maximum input voltage ratin gs or maximum output ratings, which are listed in the Specifications section, can damage the D A Q de vice and the computer . National Instruments is not liable for any damage resulting from such signal connections.
© National Instruments Corporatio n 7 USB-6501 OEM User Guide Power - On States At system startup and reset, the hardware sets all DIO lines to high-impedance inputs. The DAQ devi ce does not drive the signal high or low. Each line has a weak pu ll-up resistor connected to it.
USB-6501 OEM U ser Guide 8 ni.com Pull-up resistor .................... ................ ....4.7 k Ω VBus (nominally 5 V) Absolute voltage range .................. .........– 0.5 to 5.8 V with respect to GND Power-on state .............. .........
© National Instruments Corporatio n 9 USB-6501 OEM User Guide Power Requirements USB 4.10 to 5.25 VDC ..................... ....... 80 mA typical, 500 mA max USB Suspend ........ .............. ............ 300 µ A standby mode, 500 µ Am a x Physical Characteristics Dimensions .
USB-6501 OEM User Guide 10 ni.com specially protected secondary circuits . Such voltage measureme nts include signal le vels , special equipment, limited-energ y parts of equipment, circuits powered b y regulated lo w-v oltage sources, and electronics.
© National Instruments Corporation 11 USB-6501 OEM User Guide Note Refer to the Declaration of Conformity (DoC) for this product fo r any additional regulatory compliance informatio n.
USB-6501 OEM User Guide 12 ni.com A void contact between your bo dy and the connector block signal w hen hot swapping modules. Remove po wer from signal lines b efore connecting them to or disconnecting them from the device. Operate the device at or belo w the Measurement Category I 1 .
National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for mor e information abou t National Instruments trademarks. Other product and compan y names mentioned herein are t rademarks or trade names of their respective companie s .
Ein wichtiger Punkt beim Kauf des Geräts National Instruments USB-6501 OEM (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie National Instruments USB-6501 OEM noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für National Instruments USB-6501 OEM - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von National Instruments USB-6501 OEM reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über National Instruments USB-6501 OEM erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon National Instruments USB-6501 OEM besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von National Instruments USB-6501 OEM verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit National Instruments USB-6501 OEM. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei National Instruments USB-6501 OEM gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.