Benutzeranleitung / Produktwartung GDS 50-P des Produzenten Napoleon Grills
Zur Seite of 24
1 W415-0098 / A / 08.07.03 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.
2 W415-0098 / A / 08.07.03 Pg 2 -4 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts 5 LOCA TION & CLEARANCES 6-11 DIRECT VENT SPECIFICS MODEL GDS50 V.
3 W415-0098 / A / 08.07.03 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0098 / A / 08.07.03 FOR YOUR SA TISF ACTION, THIS ST OVE HAS BEEN TEST -FIRED T O ASSURE ITS OPERA TION AND QUAL- ITY! Minimum inlet gas supply pressure is 4.
5 W415-0098 / A / 08.07.03 As long as clearance to combustibles is kept within the required distances, the most desirable and benefical location for a Napoleon stove is in the centre of a building, thereby allowing the most efficient use of the heat created.
6 W415-0098 / A / 08.07.03 Use only Napoleon or Simpson Dura-V ent Model DV -GS venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air termi- nal locations for either system are set out in this manual and must be adhered to.
7 W415-0098 / A / 08.07.03 AIR TERMINAL INST ALLA TIONS * * * * * Recommended to prevent condensation on windows and thermal breakage * * * * * * * * * * I t i s re c o m m e n d e d t o u s e a h e at s h i e l d a n d t o m a x i m i ze t h e d i s t a n c e t o v i n y l cl a d s o f f i t s.
8 W415-0098 / A / 08.07.03 5 7 " f ir s t r u n 7 2 " s e c o n d r u n 4 8 " Use the chart on this page to calculate horizontal runs for vertical rises between 29 and 57 inches. FIGURE 8. When calculating maximum run lengths, include 10 feet for each 90° elbow or 5 feet for each 45° elbow .
9 W415-0098 / A / 08.07.03 This application occurs when venting through an ex- terior wall. FIGURES 5, 6, & 13. Having deter- mined the air terminal loca- tion, cut and frame a hole in an exterior wall with a mini- mum square or round open- ing of 9".
10 W415-0098 / A / 08.07.03 FIGURE 17 FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA TION OF THE TION OF THE TION OF .
11 W415-0098 / A / 08.07.03 In Canada, mobile home installation may be vented hori- zontally or vertically . In the United St ates, it may only be installed vertically . See "V ertical V enting" or "Horizontal Air T erminal Installation" for inst allation.
12 W415-0098 / A / 08.07.03 Follow the instructions for " Wall and Ceiling Protection". ADAPTER INST ALLA TION FIGURE 27 1. Remove the spill switch bracket from the rear of the adapter . 2. Gently pull the two wire terminals (located inside the 7" flue collar at the top of the stove) out approximately 8 inches.
13 W415-0098 / A / 08.07.03 Remove nails from the shingles above and to the sides of the chimney . Place the flashing over the vent pipe and slide it underneath the sides and upper edge of the shingles. Ensure that the vent pipe is properly centered within the flashing, giving a 3/4" margin all around.
14 W415-0098 / A / 08.07.03 Read the section on opening the door in "Finish- ing" prior to proceeding to prevent damaging the unit. Bring the gas line to the stove through either the opening in the pedestal back or through the floor directly beneath the pedestal base.
15 W415-0098 / A / 08.07.03 When opening the fire viewing door , a simple procedure must be followed in order to not damage the door . First open the valve control door . Next open both side doors fully . Pull the latch handles towards you and release each catch.
16 W415-0098 / A / 08.07.03 LOG PLACEMENT POSITIONING THE LOGS IMPROPERL Y WILL CAUSE FLAME IMPINGEMENT AND CARBONING . PHAZER TM logs and charcoal embers strips, exclusive to Napoleon Fireplaces, glow when exposed to direct flame and provide a unique and realistic glowing effect that is dif- ferent in every installation.
17 W415-0098 / A / 08.07.03 Purge all gas lines with the glass door open. Assure that a continuous gas flow is at the burner before closing the door . Allow se veral min utes (5-15) for the flame to stabi- lize after ignition.
18 W415-0098 / A / 08.07.03 5. Turn gas knob counter-clockwise to pilot. 6. Depress slightly and hold gas knob while lighting the pilot with the push button ignitor . Keep knob depressed for one minute, then release. If pilot does not continue to burn, repeat steps 3 through 5.
19 W415-0098 / A / 08.07.03 B L O W E R THERMODISC b l a c k g r o u n d VARIABLE SPEED SW ITCH w h i t e FIGURE 44 RELIEF DOOR GASKET RELIEF DOOR TWIN BLOWE FIGURE 45 1. Turn off the electrical power and the gas supply to the stove. 2. Open the lower louvre control door , the two side doors, and the fire viewing door .
20 W415-0098 / A / 08.07.03 Remove the pilot screw cap. Adjust the pilot screw to pro- vide properly sized flame. Turn in a clockwise direction to reduce the gas flow .
21 W415-0098 / A / 08.07.03 GD175 WALL TERMINAL KIT 44 BM6790 90° ELBOW - 7" DIAMETER 45 GD222 TERMINAL ASSEMBL Y 4 6 BM67ADJ 30" TO 53" ADJUST ABLE PIPE - 7" DIA 4 7 W500-0077 FI.
22 W415-0098 / A / 08.07.03 WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf S teel Ltd.
23 W415-0098 / A / 08.07.03 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
24 W415-0098 / A / 08.07.03 Main burner goes out; pilot goes out. REFER TO "MAIN BURNER GOES OUT ; PILOT ST A YS ON" Thermocouple shorting or faulty . V ent re-circulating (MODEL GDS50 ONL Y) - check joint seals and installation. - loosen and tighten thermocouple - clean thermocouple and valve connection.
Ein wichtiger Punkt beim Kauf des Geräts Napoleon Grills GDS 50-P (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Napoleon Grills GDS 50-P noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Napoleon Grills GDS 50-P - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Napoleon Grills GDS 50-P reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Napoleon Grills GDS 50-P erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Napoleon Grills GDS 50-P besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Napoleon Grills GDS 50-P verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Napoleon Grills GDS 50-P. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Napoleon Grills GDS 50-P gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.