Benutzeranleitung / Produktwartung OS10-3 des Produzenten Napoleon Fireplaces
Zur Seite of 16
INSTALLER : THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. CERTIFIED IN CANADA TO CAN/CSA 22.2 #B40.0 - M87 &·R91 B140.1 & B140.3 CER TIFIED·IN THE UNITED ST A TES TO UL 896 -199 INSTALLATION AND OPERATION INSTRUCTIONS FOR OIL-FIRED CAST IRON STOVE MODEL OS10-3 WOLF STEEL LTD.
INTRODUCTION Document n° 1092-1 EN ~ 04/02/2002 2 WARNING • The stove is an oil-fired stove. Do not burn wood or other materials in this stove. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
NAPOLEON oil stoves are manufactured under the strict Standard of the World Recognized ISO9001 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
General information Nominal heat output Oil consumption ** Chimney draft required Weight Flue outlet outside diameter max speed min speed max speed min speed 34.100 BTU/hr .31 US gal/hr .066 US gal/hr .072" w.c.g .032" w.c.g 260 lbs 5 inches 10 kW 1.
Location and clearances If the stove is to be installed on a combustible floor, it must be installed on sheet metal or a tile. The oil drip tray, 72636 (not supplied) is a suitable substitute for either of these two pads. Maintain these minimum clearances to combustibles (fig.
THE TOT AL SMOKE PIPE LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHT ABOVE THE STOVE T O A MAXIMUM HORIZONT AL RUN OF 10 FEET . All smoke pipe must slope upwards at a minimum of 1/4" per foot (6 mm/0.3m) and all connections must be tight and secured by three sheet metal screws equally spaced.
FINISHING Mounting flue collar The stove is supplied with a connection flue at rear. Smoke exit on top (figure 12, page 8) : - Remove the internal baffles on top (see page 11 ). - Fix the sealing rope in the groove on the top (2) and fit the flue spigot (1), ensuring there is a good seal.
The fuel system of this stove is designed to supply fuel by gravity pressure only. If the supply tank location is lower than the stove, it will be necessary to use the Napoleon SP32 suction pump. The SP32 should be installed a minimum of 12" above the stove carburetor and a minimum of 6" horizontally from the stove.
OPERATING INSTRUCTIONS Understanding your oil stove Furnace oil is fed from the tank to the burner floor ‘ A ’ where is it ignited by means of a firestarter. The heat produced by this flame brings the burner temperature to the required level to vaporize the fuel.
Shut down 1. T urn the control knob to “0" setting. 2. Lift the safety lever . 3. T urn off the oil tank fuel supply valve. The oil tank fuel supply valve should always be shut off when the oil stove is not in operation.
MAINTENANCE Seasonal maintenance WEEKLY - DESCALE Push and pull the de-scaling lever in and out as well as turning slightly at the same time completely two or three times. Push in for normal burner operations or before relighting. EVERY 3 TO 4 MONTHS - CLEAN BURNER Remove all three catalyser components (C, D, E, figure 13 ).
REPLACEMENTS Ordering replacement parts Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1.
Document n° 1092-1 EN ~ 04/02/2002 13 15 25 57 8 12 14 16 20 24 42 17 18 35 48 22 4 36 30 41 1 3 27 31 32 43 13 33 5 9 10 18 5 40 2 6 11 21 39 44 49 50 53 51 47 28 38 45 34 37 46 45 55 7 59 58 52 29 .
Document n° 1092-1 EN ~ 04/02/2002 14 38 306273 77 . . Back wall ..................................c ........... 0 1 38 306273 76 . . Back wall ............................ B ................. 0 1 38 306273 79 . . Back wall ...................... A .
Document n° 1092-1 EN ~ 04/02/2002 15 Notes.
Document n° 1092-1 EN ~ 04/02/2002 16 SYMPTOM PROBLEM TEST SOLUTION Flames extinguish during lighting. Very cold chimney. No draft established - leave door ajar until fire has caught. - check air supply in the room Fire extinguishes once firestarter has burnt off.
Ein wichtiger Punkt beim Kauf des Geräts Napoleon Fireplaces OS10-3 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Napoleon Fireplaces OS10-3 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Napoleon Fireplaces OS10-3 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Napoleon Fireplaces OS10-3 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Napoleon Fireplaces OS10-3 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Napoleon Fireplaces OS10-3 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Napoleon Fireplaces OS10-3 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Napoleon Fireplaces OS10-3. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Napoleon Fireplaces OS10-3 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.