Benutzeranleitung / Produktwartung TechZone des Produzenten Armstrong World Industries
Zur Seite of 20
TECHZONE ™ Ceiling Systems CEILING SYSTEMS [ Between us, ideas become reality . ] ®.
Channel your thinking The T echZone ™ Ceiling Systems provide a monolithic, uncluttered ceiling visual using standard components and organize the look of the space. A six-inch wide technical “zone” organizes services, including lighting, diffusers and sprinklers in a system that’ s pre-qualified for fit and finish.
[ PAGE TWO ] LIGHTING DIFFUSER FIRE PROTECTION T echZone Partners Armstrong has teamed with industry leaders in lighting, air diffusers and fire protection to create T echZone fixtures that are pre-qualified for fit and finish. Look for the Armstrong T echZone Compatible sign of assurance on partner specification sheets.
[ PAGE THREE ] Select your Select your ceiling T echZone Select your module on-center field panel material and size spacing Optima Ultima 4' 4'-0" 4' 4'-6" 4' 6&apos.
[ PAGE FOUR ] Suspension system colors have been coordinated with field panels, technical panels and partner fixtures. Select your field panel edge detail and suspension system (All field panels not available in all edge detail options. See layouts, pg.
Layout configurations T echZone ™ Ceiling Systems offer many configuration options to meet just about any design and functional need. T echZone is engineered for 4' and 5' building modules. T echnical zone on-center spacing can be as narrow as 4' and as wide as 10'-6".
4' on-center technical zone [ 4' BUILDING MODULES ] [ PAGE SIX ] 42" x 48" FIELD PANELS 9/16" Grid Optima Sq. T egular Item #3287 21" x 24" FIELD PANELS 9/16" Grid Optima Sq. T egular Item #3279 24" x 42" FIELD PANELS 9/16" Grid Optima Sq.
4'-6" on-center technical zone [ 4' BUILDING MODULES ] [ PAGE SEVEN ] 48" x 48" FIELD PANELS 15/16" Grid Optima Sq. Lay-in Item #3160 15/16" Grid Optima Sq. T egular Item #3255 9/16" Grid Optima Sq. T egular Item #3256 24" x 24" FIELD PANELS 15/16" Grid Optima Sq.
[ 4' BUILDING MODULES ] 6'-6" on-center technical zone 7'-6" on-center technical zone [ PAGE EIGHT ] 42" x 48" FIELD PANELS 9/16" Grid Optima Sq. T egular Item #3287 24" x 72" FIELD PANELS 15/16" Grid Optima Sq.
[ 4' BUILDING MODULES ] 8'-6" on-center technical zone 48" x 48" FIELD PANELS 15/16" Grid Optima Sq. Lay-in Item #3160 15/16" Grid Optima Sq. T egular Item #3255 9/16" Grid Optima Sq. T egular Item #3256 24" x 96" FIELD PANELS 15/16" Grid Optima Sq.
[ PAGE TEN ] Optima 30" x 30" T egular field panels and Metal T egular technical panels on Suprafine suspension system. Neo-Ray recessed light fixtures.
5' on-center technical zone 30" x 54" FIELD PANELS 9/16" Grid Optima Sq. T egular Item #3284 20" x 54" FIELD PANELS 9/16" Grid Optima Sq. T egular Item #3276 27" x 30" FIELD PANELS 9/16" Grid Optima Sq.
[ PAGE TWEL VE ] 5'-6" on-center technical zone [ 5' BUILDING MODULES ] 20" x 60" FIELD PANELS 15/16" Grid Optima Sq. Lay-in Item #3156 15/16" Grid Optima Sq. T egular Item #3278 9/16" Grid Optima Sq. T egular Item #3277 30" x 60" FIELD PANELS 15/16" Grid Optima Sq.
[ PAGE THIRTEEN ] Optima 48" x 48" T egular field panel and Optima Lay-In technical panels on Suprafine suspension system. Lithonia recessed light fixtures.
10'-6" on-center technical zone 8' on-center technical zone [ 5' BUILDING MODULES ] 20" x 60" FIELD PANELS 15/16" Grid Optima Sq. Lay-in Item #3156 15/16" Grid Optima Sq. T egular Item #3278 9/16" Grid Optima Sq.
T echZone ™ Field Panels KEY SELECTION A TTRIBUTES ■ Nondirectional DuraBrite ® surface for excellent durability and superior light reflectance (reduces lighting and energy costs by up to 23%) ■ Optima - Outstanding acoustical performance for open plan areas, both Articulation Class (180-190) and NRC (0.
Stabilizer Clip for Optima, Item 435 Recommended for panels 5' and greater in length. Ordered separately . Note: Panels 5' to 8' – One clip installed near the mid-point of each long edge.
[ PAGE SEVENTEEN ] T echZone partners Industry-leading suppliers have engineered and designed lighting, diffusers and fire protection products for use in T echZone ™ Ceiling Systems. All Armstrong T echZone compatible products are qualified for fit and finish with T echZone Ceiling Systems.
[ PAGE EIGHTEEN ] LIGHTING RECESSED FIXTURES ■ 6" x 48" and 6" x 60" ■ Lay-in and T egular Edges ■ 9/16" and 15/16" grid compatible RECESSED DOWNLIGHTS ■ 3.
CEILING SYSTEMS [ Between us, ideas become reality . ] ® T echLine SM / 1 877 ARMSTRONG 1 877 276 7876 armstrong.com/ceilings 10% post consumer waste.
Ein wichtiger Punkt beim Kauf des Geräts Armstrong World Industries TechZone (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Armstrong World Industries TechZone noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Armstrong World Industries TechZone - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Armstrong World Industries TechZone reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Armstrong World Industries TechZone erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Armstrong World Industries TechZone besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Armstrong World Industries TechZone verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Armstrong World Industries TechZone. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Armstrong World Industries TechZone gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.