2 78D001 1 WD V Series Gas F ireplace .
78D001 1 3 WD V Series Gas F ireplace 4. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flam- mable objects are less than 42" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas 5.
4 78D001 1 WD V Series Gas F ireplace 14. Do not use any solid fuels (wood, coal, paper , card- board, etc.) in this fireplace. Use only the gas type indicated on rating plate.
78D001 1 5 WD V Series Gas F ireplace Figure 1 - WDV Fireplace Features • This appliance has been certified for use with either natural or propane gas.
6 78D001 1 WD V Series Gas F ireplace .
78D001 1 7 WD V Series Gas F ireplace Plan for the installation of your appliance.
8 78D001 1 WD V Series Gas F ireplace 72” Minimum Ceiling 12” Max. Depth 2 1 / 2 ” Max Depth 6” Min. From Opening 12” Min. From Opening 6” Min.
78D001 1 9 WD V Series Gas F ireplace FP2430 secure fireplac e 6” The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor . Use four (4) screws to attach fireplace to framing.
10 78D001 1 WD V Series Gas F ireplace Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation.
78D001 1 1 1 WD V Series Gas F ireplace There are two basic types of direc.
12 78D001 1 WD V Series Gas F ireplace Figure 8 - Horizontal V ent Termination Location V ent T erminal Air Supply Inlet Area Where T .
78D001 1 13 WD V Series Gas F ireplace V G G=6" (152mm) F F=6" (152mm) V V G G = Combustible 24"(610mm) Noncombustible 18"(457mm) Combustible & Noncombustible H = 24" (610.
14 78D001 1 WD V Series Gas F ireplace .
78D001 1 15 WD V Series Gas F ireplace A 10’ B 7’ 10’ FP2426 max vent run w/elbows Figure 14 - Maximum V ent Run with Elbows A +.
16 78D001 1 WD V Series Gas F ireplace This gas fireplace has been approved for , • V ertical installations up to 40' (12 m) in height.
78D001 1 17 WD V Series Gas F ireplace 1. Determine the route your vertical venting will take.
18 78D001 1 WD V Series Gas F ireplace 3. Cut a hole in the roof using the locating hole as a center point. (Cover any exposed open vent pipes before cutting hole in roof). The 10 Zx "x10 Zx " (241 x 241 mm) hole must be measured on the horizontal.
78D001 1 19 WD V Series Gas F ireplace 1. Flexible UL1777 listed venting may be used in any vent ing appl ication where rigid direct ven t compo nents can be used.
20 78D001 1 WD V Series Gas F ireplace T ermination Cap Storm Collar Roof Support Flashing Rigid Pipe Length Flex to Pipe Adapter (.
78D001 1 21 WD V Series Gas F ireplace Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace.
22 78D001 1 WD V Series Gas F ireplace The gas line connection may be made using 1/2" rigid tubing or an approved flex connector .
78D001 1 23 WD V Series Gas F ireplace 1. Check gas type.
24 78D001 1 WD V Series Gas F ireplace COMMAND CENTER 4-AA BA TTERY COMP ARTMENT MASTER SWTICH CONVERSION NG/LP RF RECEIVER ON/OFF BUTTON ON/HI OFF/LO LED IGNITER/SP ARKER SENSING RED/THERMOPILE BLACK.
78D001 1 25 WD V Series Gas F ireplace .
26 78D001 1 WD V Series Gas F ireplace 1. Remove the front access door by lifting up and sliding the two (2) spring hinge pins inward and lifting off.
78D001 1 27 WD V Series Gas F ireplace 1. For best results, place the stones first. 2. Place the stones randomly against the stone stop bracket, in front of and behind the burner .
28 78D001 1 WD V Series Gas F ireplace This appliance is equipped with an ignition device which automatically lights the pilot.
78D001 1 29 WD V Series Gas F ireplace 1. Read the safety information above.
30 78D001 1 WD V Series Gas F ireplace .
78D001 1 31 WD V Series Gas F ireplace System configuration/setup is done on the Command Center .
32 78D001 1 WD V Series Gas F ireplace .
78D001 1 33 WD V Series Gas F ireplace Figure 39 The RFSC Remote Control has two (2) operating modes: Manual and Thermostatic.
34 78D001 1 WD V Series Gas F ireplace Figure 43 1. Hold AUT O button for five (5) seconds and one number and flame icon will appear in LCD screen.
78D001 1 35 WD V Series Gas F ireplace Figure 47 1. Press AUX button once to turn ON. AUX shows on the LCD.
36 78D001 1 WD V Series Gas F ireplace The fla mes from the bu rner sh ould be visually checked as soon as the hea ter i s in sta lled and periodi cal ly durin g normal operation. In normal operation, at full rate, and after operating for about 15 to 30 minu tes , the flam e shoul d be yellow .
78D001 1 37 WD V Series Gas F ireplace The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person.
38 78D001 1 WD V Series Gas F ireplace OPERA TION Install batteries and/or plug in the AC board Flip the master switch (rocker switch) to the ON positi.
78D001 1 39 WD V Series Gas F ireplace 1 2 3 5 7 6 780012 DVW firebox parts 1.
40 78D001 1 WD V Series Gas F ireplace 780012 DVW SG par ts 6/09 1 2 3 4 .
78D001 1 41 WD V Series Gas F ireplace 1.
42 78D001 1 WD V Series Gas F ireplace HOT 1 2 3 4 5 6 9 7 8 10 730024 KHLDV vent parts .
78D001 1 43 WD V Series Gas F ireplace .
44 78D001 1 WD V Series Gas F ireplace 1. White Stone #1 5 78D0122K 2. Light Gray Stone #2 5 78D0123K 3.
78D001 1 45 WD V Series Gas F ireplace.
46 78D001 1 WD V Series Gas F ireplace This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.
78D001 1 47 WD V Series Gas F ireplace The follow.
149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com .
Ein wichtiger Punkt beim Kauf des Geräts Monessen Hearth WDV500 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Monessen Hearth WDV500 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Monessen Hearth WDV500 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Monessen Hearth WDV500 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Monessen Hearth WDV500 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Monessen Hearth WDV500 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Monessen Hearth WDV500 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Monessen Hearth WDV500. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Monessen Hearth WDV500 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.