This is an unvented gas- fi red heater . It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided.
2 23D8020 CONTENTS Important Safety Information ..................................3 Product Features ......................................................5 Operation ..............................................................5 Natural Gas ........
23D8020 3 9. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.l/NFPA54. 10. This unit complies with ANSI Z21.11. Unvented Heat- ers. 11. Do not install the heaters in a bathroom or bedroom.
4 23D8020 IMPORT ANT SAFETY INFORMA TION Continued from page 3 16. Keep room area clear and free from combustible materi- als, gasoline and other flammable vapors and liquids. 17. Unvented gas heaters are a supplemental zone heater. They are not intended to be the primary heating appliance.
23D8020 5 Your vent-free fireplace must be mounted to the floor or the fireplace hearth. OPERA TION This unvented gas heater requires no outside venting and burns cleanly with high heating efficiency.
6 23D8020 NA TURAL GAS Milli-Volt and T-Stat Pressure Regulator Pressure Setting: 3.5" w.c. Pilot Regulator: 3.5" w.c. Gas Inlet Pressure: Max. 10 1/2" w. c. Min. 5" w.c. PRODUCT FEA TURES AND SPECIFICA TIONS PROP ANE/LPG Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.
23D8020 7 GETTING ST ARTED MAKE SURE YOU HA VE RECEIVED ALL P ARTS Check your packing list to verify that all listed parts have been received. You should have the following: • Installation/Operating instructions • Black Louvers (5) • 33" unvented gas heater with brick panels.
8 23D8020 REMOVING SCREEN Remove fireplace screen by pushing screen frame panel up and out. See Figure 2. Figure 2 - Removing Fireplace Screen GENERAL INST ALLA TION INFORMA TION INST ALLING CANOPY 1. Remove the fireplace screen as described in the previous section.
23D8020 9 GENERAL INST ALLA TION INFORMA TION CODES Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1 or NFPA54 which can be obtained from… American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 or National Fire Protection Association, Inc.
10 23D8020 W H BTU/Hr = BTU/Hr = BTU/Hr = W ARNING The following formula can be used to determine the maximum heater rating per the definition of unconfined space: (L 1 + L 2 ) Ft x (W) Ft x (H) Ft 50 Consider two connecting rooms with an open area between, with the following dimensions: L 1 = 15 1 / 2 Ft.
23D8020 11 33" 15 1 / 4 " 22 3 / 4 " 23 7 / 8 " B A 9" Minimum 9" Minimum 42" Minimum CLEARANCES AND HEIGHT REQUIREMENTS NOTE: Clearances are necessary to combustible surfaces only . No clearance is necessary for noncombustible surface.
12 23D8020 10" 12" 14" 26" 8" 12" 10" 8" 6" 2 1 / 2 " Hood No combustible materials within 8” of opening. Do not cover louv ers. No combustible materials within 8" of opening. Do not cover louvers.
23D8020 13 Combustible Material Non-combustible Material 5" 1” CLEARANCES and HEIGHT REQUIREMENTS The gas log heater must be installed at least 5" above any combustible flooring material, such as carpeting or tile, which is closer than 14" to the base of the fireplace.
14 23D8020 22 5 / 8 " 33 1 / 2 " 16 " 33 1 / 2 " 16 " 33 1 / 2 " 27 1 / 2 " 22 5 / 8 " 31 7 / 8 " REF 16 " 37 1 / 4 " 45 3 / 4 " 15 3 / 8 &q.
23D8020 15 NOTE: Clearance requirements as detailed in “Clearances and Height Requirements” section of this manual must be met before securing heater in place. To prevent movement, the heater must be secured to the floor or hearth. 1. Lift off louvers and remove the screen.
16 23D8020 NOTICE: A quali fi ed gas appliance installer must connect the heater to the gas supply . Consult all local codes. IMPORT ANT : Loosen the pipe adapter on the fl ex tube before installing to the system piping. Figure 17 - Gas Connection T o Heater V alve Stainless Flexible T ube CONNECTING THE GAS Use new black or steel pipe.
23D8020 17 To reach factory installed flex line, go through access door on right or left side of firebox. CONNECTING THE GAS CHECK GAS TYPE: The gas supply must be the same as stated on heater's rating plate. Located behind the control access door (Figure 1, page 5).
18 23D8020 CHECKING GAS PRESSURE Test all gas joints from the gas meter to the heater valve for leaks using a gas analyzer or soap and water solution after com- pleting connection. DO NOT USE AN OPEN FLAME. Check the gas pressure with the appliance burning and the control set to HIGH .
23D8020 19 ELECTRICAL WIRING (MILLI-VOL T) The milli-volt valve is a self-powered combination gas control THA T DOES NOT REQUIRE 1 10 V AC TO OPERA TE.
20 23D8020 ELECTRICAL WIRING (MILLI-VOL T) A. COMPLETE MILLIVOL T SYSTEM CHECK (“A” Reading - Thermostat contacts CLOSED - Control Knob “ON” - Main burner should turn ON) a. If the reading is more than 100 milli-volts and the automatic valve still does not come on, replace the control.
23D8020 21 ELECTRICAL WIRING (F AN) If any of the original wire as supplied with the fireplace must be replaced, contact dealer for proper replacement wiring har- ness. (see parts list for part number) . 120 volts, 60Hz, 1 amps. Electrical power cord (plug) can be routed to exit the DIS33 on either the left side or the right side.
22 23D8020 LOG PLACEMENT Figure 23 - Installing Rear Log (#1) Before you begin — This unit is supplied with six (6) ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers.
23D8020 23 LOG PLACEMENT Figure 25 - Installing Left Base Log (#3) Left Base Log (#3) Pins Figure 26 - Installing Right Front Log (#4) Right Front Log (#4) Right Front Log (#4) Pins 4. Place right front log (#4) on two pins on bottom right side of grate.
24 23D8020 LOG PLACEMENT Figure 27 - Installing Left T op Log (#5) Left T op Log (#5) 5. Place right end of left top log (#5) on bottom center grate pin.
23D8020 25 LOG PLACEMENT 6. Place right top log (#6) on two pins to the left of right base log. See Figure 29. PLACING ROCK WOOL After installing logs, place TPB-RW (Rock Wool) in dime-size pieces evenly across the burner surface in between the logs. Do not add additional rock wool.
26 23D8020 FLAME APPEARANCE Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition, periodically check the flames visually during operation. CHECKING THE PILOT FLAME The pilot fl ame must always be present when the heater is in operation.
23D8020 27 In normal operation at full rate after 15 minutes, the following flame appearances should be observed: Figure 33 - Correct Appearance of Rear Flames Burner will have a random pattern of yellow flames as shown in Figure 33. There should be glowing embers on the front burner.
28 23D8020 W ARNING Figure 34 - Location of Piezo Ignitor , Control Knobs and Switch on Milli-V olt Unit, Hi/Lo Remote Control and Manual Unit A. This appliance is equipped with a piezo ignition device which automatically lights the pilot. If the piezo is not working properly see Match Lighting Instructions on page 30.
23D8020 29 OPERA TING INSTRUCTIONS 1. STOP! Read the safety information label. 2. Make sure the manual shutoff valve is fully open. 3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo ignitor does not light the pilot, refer to instructions for “Match Lighting Instructions,” page 30.
30 23D8020 1. Remove any items necessary for easy access to the pilot (for example: logs, screens, etc.). 2. Follow appropriate lighting instructions found previously. Instead of pushing and releasing the piezo button, light a match and hold the flame to the end of the pilot and ignite the pilot.
23D8020 31 Annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting. PERIODIC CLEANING - Refer to parts diagram for location of items discussed below . • Do not use cleaning fluid to clean logs or any part of heater.
32 23D8020 OBSERVED PROBLEM When ignitor button is pressed, there is no spark at ODS/pilot. Appliance produces unwanted odors. Appliance shuts off during use. Gas odor even when control knob is in OFF position. When ignitor button is pressed, there is spark at ODS pilot, but no ignition.
23D8020 33 OBSERVED PROBLEM ODS/pilot lights, but flame goes out when control knob is released. Burner does not light after ODS/ pilot is lit. Burner backfires during com- bustion. Slight smoke or odor during initial operation. Logs appear to smoke after ini- tial operation.
34 23D8020 1 2 3 4 8 8 8 8 8 8 13 7 5 6 14 12 Failure to position the parts in accordance with these diagrams or failure to use only parts speci fi cally approved with this appliance may result in property damage or personal injury .
23D8020 35 REPLACEMENT P ARTS LIST Item Qty Description DIS33N/P 1 1 Screen Assembly 23D8028 2 1 Canopy Assembly 23D8027 3 2 T op Black Louver 23D0200K 4 1 Bottom Black Hang On Louver Assembly 23D8017.
36 23D8020 5 6 3 4 8A 8B 1 2 7 ILLUSTRA TED P ARTS BREAKDOWN Failure to position the parts in accordance with these diagrams or failure to use only parts speci fi cally approved with this appliance may result in property damage or personal injury .
23D8020 37 REPLACEMENT P ARTS LIST REPLACEMENT P ARTS ARE A V AILABLE THROUGH YOUR RET AILER. Item Description Qty DIS33N DIS33P Common Parts 1 Piezo Ignitor 1 14D0503 14D0503 2 Piezo Wire 1 00K0632 0.
38 23D8020 #1 #2 #4 #5 #3 #6 REPLACEMENT P ARTS ARE A V AILABLE THROUGH YOUR RET AILER. ILLUSTRA TED P ARTS BREAKDOWN Failure to position the parts in accordance with these diagrams or failure to use only parts speci fi cally approved with this appliance may result in property damage or personal injury .
23D8020 39 NOTES.
MA Y 2006 P/N 23D8020 • Rev . 4 LIMITED LIFETIME W ARRANTY POLICY The following components are warranted for life to the original owner, subject of proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate, and Stainless Steel Burners.
Ein wichtiger Punkt beim Kauf des Geräts Monessen Hearth VENT-FREE DIS33G (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Monessen Hearth VENT-FREE DIS33G noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Monessen Hearth VENT-FREE DIS33G - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Monessen Hearth VENT-FREE DIS33G reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Monessen Hearth VENT-FREE DIS33G erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Monessen Hearth VENT-FREE DIS33G besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Monessen Hearth VENT-FREE DIS33G verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Monessen Hearth VENT-FREE DIS33G. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Monessen Hearth VENT-FREE DIS33G gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.