MODELS: HBDV300 & HBDV400 W ARNINGS IF THE INFORMA TION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE. – Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
2 54D5031 CONTENTS Important Safety Information .......................... 3 Product Features .............................................. 5 Code Approval .................................................. 5 Pre-Installation Information ............
54D5031 3 4. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less than 42" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas 5.
4 54D5031 IMPORT ANT SAFETY INFORMA TION Continued from page 3 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Never place anything on top of fireplace. 14. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace.
54D5031 5 PRODUCT FEA TURES AND CODE APPROV AL Off/Pilot/On Knob Optional Remote Receiver Figure 1 - HBDV300 and HBDV400 Fireplace • This appliance has been certi- fied for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels.
6 54D5031 PRE-INST ALLA TION INFORMA TION ORIFICE SIZES, PRESSURES AND BTUs NA TURAL GAS PROP ANE GAS Manifold Press: (W.C.) 3.5" Manifold Press: (W.C.) 10" Maximum Supply Pressure 10.5" Maximum Supply Pressure 13" Minimum Supply Pressure 4.
54D5031 7 B A D F H A E C 1/2” or 5/8” C A A C G G 1/2” or 5/8” 1/2” or 5/8” FIREPLACE FRAMING Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following Figure 2 and the chart below for your specific installation requirements.
8 54D5031 E H D A G F L M O J 3½" ⅝ " ⅝ " ½" ½" I B 8¼" I N C K PRE-INST ALLA TION INFORMA TION DESCRIPTION Key Letter HBDV300 HBDV400 Overall Front Width A 33 1 .
54D5031 9 Y E A B C D F Y X PRE-INST ALLA TION INFORMA TION FIREPLACE LOCA TION Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuratio n to be used, framing and finishing details, and whether any optional accessories (i.
10 54D5031 0"–12" Maximum Depth 12" Minimum 71"Minimum Minimum 4" From Both Side W alls FIREPLACE WALL COMBUSTIB L MATERIAL AREA 4" 3" 2.5" 45° 2.5" 2.5" 1" 1.5" 1.5" STUD Follow these instructions carefully to ensure safe installation.
54D5031 11 The fireplace must be secured to the floor and/or to framing studs as shown in Figure 5. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side nailing flanges are 1/2" or 5/8" to accommodate different wall thickness.
12 54D5031 Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury , property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury , property damage or loss of life.
54D5031 13 3" 1" 1" 1" 3" 1" 1" VENT INST ALLA TION Figure 7 - Combustible Clearances for V ent Pipe W ARNING WARNING This fireplace must be vented to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance.
14 54D5031 Figure 9 - Removing Screws from Flue Pipe Adapter and Flue Pipe Cover Figure 10 - Removing Flue Pipe Figure 1 1 - Attaching Flue Pipe to T op Vent Con fi gurations Screws Flue Pipe Screws .
54D5031 15 VENT INST ALLA TION INST ALLA TION PLANNING There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose.
16 54D5031 V V V V V V V V D L E B C F B B BB B M I A A J H G A Operable Fixed Closed Fixed Closed Opera- ble K A A A G VENT INST ALLA TION Always maintain minimum clearances around vent systems.
54D5031 17 V G G=6" (152mm) F F=6" (152mm) V V G G = Combustible 24"(610mm) Noncombustible 18"(457mm) Combustible & Noncombustible H = 24" (610mm) J = 20" (508mm) V H.
18 54D5031 9 1 / 2 " (241mm) 9 1 / 2 " (241mm) 3 3 / 4 " (92mm) 7 1 / 2 " (190mm) Maximum 20" T op V iew Flat Installation REAR (THROUGH THE W ALL) APPLICA TIONS When installe.
54D5031 19 HOT HOT VENT INST ALLA TION 4. Apply a bead of non-hardening mastic around the outside edge of vent cap. Position the vent cap in the center of hole on the exterior wall with the word “HOT” on the vent cap facing up. Insure proper clearance of 1" to combustibles is maintained to the flue.
20 54D5031 VENT INST ALLA TION HORIZONT AL TERMINA TION CONFIGURA TIONS Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to.
54D5031 21 HORIZONT AL TERMINA TION CONFIGURA TION (Continued) • If a 90° elbow is used in the horizontal vent run (level height maintained) the horizontal vent length is reduced by 36". See Figures 21 and 22, page 20. This does not apply if the 90° elbows are used to increase or redirect a vertical rise.
22 54D5031 VENT INST ALLA TION BELOW GRADE INST ALLA TIONS When it is not possible to meet the required vent terminal clearances of 12" above grade level, a snorkel kit is recommended. It allows installation depth down to 7" (178mm) below grade level.
54D5031 23 40' Maximum Height 8' Minimum Height 10' Maximum Support Straps Every 3' 40' Maximum Height 8' Minimum Height 10' Maximum Support Straps Every 3' Sup.
24 54D5031 9 1 / 2 " 9 1 / 2 " VENT INST ALLA TION INST ALLA TION FOR VERTICAL TERMINA TION 1. Determine the route your vertical venting will take. If ceiling joist, roof rafters or other framing will obstruct the venting system, consider an offset.
54D5031 25 ROOF PITCH H (feet) Flat to 6/12 1.0 Over 6/12 to 7/12 1.25 Over 7/12 to 8/12 1.5 Over 8/12 to 9/12 2.0 Over 9/12 to 10/12 2.5 Over 10/12 to 1 1/12 3.25 Over 1 1/12 to 12/12 4.0 *H = Minimum height from roof to lowest discharge opening of vent.
26 54D5031 FLEX VENT INST ALLA TION Flex vent pipe spacers: Refer to manufacturer ’s speci fi cations for correct positioning of the spacer springs to maintain proper distance between inside and outside pipe.
54D5031 27 FLEX VENT INST ALLA TION Figure 4 — T ypical pipe connection Figure 3 — T ypical vertical fl ex vent installation Figure 5 — T ypical horizontal fl ex vent installation T ermination.
28 54D5031 Figure 39 - External Regulator with V ent Pointing Down (Propane/LP Only) Use only new black iron or steel pipe. Internally tinned copper or copper tubing can be used per National Fuel Code, section 2.6.3, providing gas meets hydrogen sulfide limits, and where permitted by local codes.
54D5031 29 3" Minimum FIREPLACE INST ALLA TION A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1 / 8 " NPT pressure tapping point should be installed upstream of the appliance. See Figure 39. IMPORT ANT : Install main gas valve (equipment shutoff valve) in an accessible location.
30 54D5031 CHECKING GAS PRES SURE AND ELECTRICAL INST ALLA TION 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately.
54D5031 31 ON OFF OPTIONAL REMOTE RECEIVER ON OFF RS PILOT HI LO ON OFF TH TP TH/TP ON OFF OPTIONAL W ALL SWITCH GRA Y BLUE BLACK BLACK BLACK BLUE WHITE RS REMOTE W ALL SWITCH Position the wall switch.
32 54D5031 Glass Frame Clamps Figure 44 - Removing Glass Frame GLASS REMOV AL & BRICK INST ALLA TION GLASS FRAME REMOV AL 1. Release two clamps on bottom of fireplace. See Figure 44. 2. Tilt glass frame out and lift glass frame up until it clears three tabs on top of fireplace.
54D5031 33 Figure 47 - Placement of Log 1. Figure 46 - Placement of Rock Wool on Burner Figure 45 a & b - Placement of Rock Wool on Burners HBDV400 HBDV300 FINAL INST ALLA TION Log #1 Cover with Rock Wool Burner PLACEMENT OF LA V A ROCK, ROCK WOOL AND LOGS 1.
34 54D5031 Log #4 Log #5 Log #2 Log #3 FINAL INST ALLA TION Figure 49 - Placement of Log 3 Figure 50 - Placement of Log 4 Figure 51 - Placement of Log 5 Figure 48 - Placement of Log 2 6a. For 400 models, place log #3 into place by matching the notch on the side of the log with the protrusion on the rear log.
54D5031 35 Log #6 Log #7 FINAL INST ALLA TION Figure 52 - Placement of Log 6 Figure 53 - Placement of Log 7 (HBDV400 only). T op andiron hole Lower andiron hole T op bracket slot Lower bracket slot Horizontal fi replace grate bar Figure 55 - Universal Andirons Figure 54 a & b - Andiron Placement (400DVBH and 300DVBH).
36 54D5031 A. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
54D5031 37 PILO T O F F P I L O T O N Continued on next page APPROVED LEAK TESTING METHOD You may check for gas leaks with the following methods only: • Soap and water solution • An approved leak testing spray • Electronic sniffer If using a soap and water solution to test for leaks, DO NOT spray solution onto control body .
38 54D5031 T PILO T O F F P I L O T O N O F F P I L O T O N PILO T Figure 58 - On Position PILO T O F F P I L O T O N Figure 57 - On/Off/RS Switch OFF ON RS OPERA TING INSTRUCTIONS (MILLIVOL T) LIGHTING BURNER MAIN BURNER SWITCH The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace.
54D5031 39 Figure 61 - Pilot Flame Thermopile Thermocouple Figure 62 - Burner Flame Appearance T urn off gas before servicing fi replace. It is recommended that a quali fi ed service technician perf.
40 54D5031 CLEANING AND MAINTENANCE VENT SYSTEM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow.
54D5031 41 TROUBLESHOOTING ST ANDING PILOT IGNITION SYMPTOM POSSIBLE CAUSE ACTION 1. Spark ignitor will not light pilot after repeated triggering of piezo.
42 54D5031 TROUBLESHOOTING ST ANDING PILOT IGNITION SYMPTOM POSSIBLE CAUSE ACTION 4. Frequent pilot outage problem. 5. The pilot and main burner extinguish while in operation 6. Glass Soots 7. Flame burn blue and lifts off burner (ghost- ing) A. Pilot flame may be too high or too low, causing pilot safety to drop out A.
54D5031 43 1 2 3 5 6 7 10 4 9 11 REPLACEMENT P ARTS FIREPLACE COMPONENTS.
44 54D5031 FIREPLACE COMPONENTS REPLACEMENT P ARTS CC=Cottage Clay CR=Cottage Red Item Description Qty HBDV300 HBDV400 Standard Features 1 Junction Box Assembly 1 26D2128K 26D2128K 2 Black Louver (eac.
54D5031 45 8A (HBDV400) 8B (HBDV300) 1 1, 12, 13, 14, 15 3 4 5 6 7 8 2 1 2T 2 I 2C 10 REPLACEMENT P ARTS MILLIVOL T ENGINE.
46 54D5031 HOT 1 3 4 5 6 7 8 9 10 2 11 MILLIVOL T COMPONENTS REPLACEMENT P ARTS ITEM DESCRIPTION QT y HBDV300NV HBDV300PV HBDV400NV HBDV400PV 1 Gas V alve Assembly 1 37D01 17 37D01 18 37D01 17 37D01 1.
54D5031 47 REPLACEMENT P ARTS For more information about, or instructions for, the venting components referenced above, please contact the compo- nent manufaturer: Selkirk Corporation: www. selkirkcorp.com or 800-992-8368 Simpson Duravent: www. duravent.
48 54D5031 5 6 4 3 2 1 7 Item Description Qty HBDV300 HBDV400 1 Rear Log 1 54D51 19 54D5023 2 Right Log 1 54D5120 54D5024 3 Left Log 1 54D5121 54D5025 4 Mid T op Log 1 54D5123 54D5026 5 Right T op Log.
54D5031 49 NOTES NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fi tter when installed within the Commonwealth of Massachu- setts. Any residence with a direct vent product must have a CO detector installed in the residence.
50 54D5031 NOTES SPECIAL REQUIREMENTS CONTINUED 2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFP A 720 and be ANSI/UL 2034 listed and IAS certi fi ed. 3. SIGNAGE.
54D5031 51 NOTES.
52 54D5031 NOTES.
54D5031 53 NOTES.
JUL Y 2008 P/N 54D5031 • Rev . 4 LIMITED LIFETIME WARRANTY POLICY LIFETIME W ARRANTY The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners.
Ein wichtiger Punkt beim Kauf des Geräts Monessen Hearth HBDV400 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Monessen Hearth HBDV400 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Monessen Hearth HBDV400 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Monessen Hearth HBDV400 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Monessen Hearth HBDV400 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Monessen Hearth HBDV400 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Monessen Hearth HBDV400 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Monessen Hearth HBDV400. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Monessen Hearth HBDV400 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.