For use with a listed gas-fired unvented decorative room heater not to exceed 40,000 BTU/hr . Do Not Build a Wood Fire. READ AND SA VE THESE INSTRUCTIONS W ARNINGS If the information in this manual is not followed exactly , a fi re or explosion may result causing property damage, personal injury or loss of life.
2 71D0530 CONTENTS Important Safety Information ................................. 3 Product Features ......................................................5 Before Y ou Start .....................................................5 General Installation Information .
71D0530 3 9. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.l/NFPA54. 10. This unit complies with ANSI Z21.91 ventless firebox enclosures for gas-fired unvented decorative room heat- ers.
4 71D0530 IMPORT ANT SAFETY INFORMA TION Continued from page 3 16. Keep room area clear and free from combustible materi- als, gasoline and other flammable vapors and liquids. 17. Unvented gas heaters are a supplemental zone heater. They are not intended to be a primary heating appli- ance.
71D0530 5 The new GCUF and GRUF Series are vent-free fireboxes. They feature a self contained heat-circulating system. These units also feature a 2-in1, flexible-face system, sold as an accessory, that converts the circulating system into a radiant system in seconds.
6 71D0530 L J K 5 7/16" G F D E C 34 1/2" H A B I 1 1/4" 21 3/4" 6" 1 5/16" 2 1/2" 1 ¼" 5 7 / 16 " 21 ¾" 2 ½" 1 5 / 16 " 6" 34 ½&qu.
71D0530 7 E MINIMUM HEARTH DIMENSIONS GENERAL INST ALLA TION INFORMA TION AND LOCA TION OF FIREBOX Figure 2 - Minimum Hearth Dimensions LOCA TION OF FIREBOX Carefully select the best location for installation of your vent-free firebox.
8 71D0530 9" Minimum 42" Minimum 9" Minimum Ensure that minimum clearances shown in Figures 4 through 8 are maintained. Left and right clearances are determined when facing the front of the firebox. Follow these instructions carefully to ensure safe installation.
71D0530 9 4. Mantel clearances: The canopy supplied with the unit must be installed. If a combustible mantel is installed, it must meet the clearance requirements as shown in Figure 6a . However, if lower mantel height is desired, refer to page 14 and see Figure 6b.
10 71D0530 H G D F E A C B A 1 / 2 "o r 5 / 8 " C A G C G A 1 / 2 " or 5 / 8 FIREPLACE FRAMING Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following Figures 9 through 12 and the chart below for your specific installation requirements.
71D0530 11 K J FIREPLACE FRAMING GCUF32C with trim GCUF36C with trim GCUF42C with trim K 37 ⅞ " 41 ⅞ " 47 ⅞ " J 35 ⅞ " 35 ⅞ " 35 ⅞ " 1. Bend out the nailing flanges located on each side of the firebox. 2. Slide the firebox into prepared framing or position firebox in its final position and frame later.
12 71D0530 GAS LINE INST ALLA TION Consult all local codes. All gas piping must be installed to comply with local codes, or in the absence of local codes, with the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA54. Remove the baseplate for ease of gas line installation.
71D0530 13 CANOPY INST ALLA TION INST ALLING CANOPY A canopy is furnished with each firebox and MUST be installed for safe operation. See Figure 14. 1. Align the canopy with the holes in the top frame. 2. Secure the screws as shown. 3. Tighten side screws.
14 71D0530 Electrical connections should only be performed by a quali fi ed, licensed electrician, main power must be off when connecting to main electrical power supply or performing service.
71D0530 15 4 1 5 6 4 2 3 7 ILLUSTRA TED P ARTS LIST ITEM DESCRIPTION QTY GCUF32C GCUF36C GCUF42C 1 Canopy 1 71D0023 71D0500 71D1000 2 Screen Panel 2 61D0001 61D0001 61D0003 3 Screen Rod 2 26D0138 26D0.
16 71D0530 8'max. FOR USE OF OPTIONAL AK-4 OUTSIDE AIR KIT COMBUSTION AIR 1. Locate combustion air assembly at an exterior location which is not likely to be accidentally blocked in any manner . Locate assembly a min. of 12" above the snow line to prevent blockage by snow accumulation.
71D0530 17 FOR USE OF OPTIONAL AK-4 OUTSIDE AIR KIT The use of outside air for combustion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of the fi replace. Use the model AK4 combustion air kit.
18 71D0530 MODEL AK-4 COMBUSTION AIR ASSEMBL Y (CONTINUED) 7. If the duct is the insulated type, push the insulation back from one end of the duct approximately 2". See Figur e 23. 8. Slip the exposed end of the duct over the starting collar on the fi replace .
71D0530 19 NOTES.
MA Y 2008 P/N 71D0530 • Rev . 6 MONESSEN HEARTH SYSTEMS LIMITED LIFETIME W ARRANTY POLICY The following components are warranted for life to the original owner, subject of proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate, and Stainless Steel Burners.
Ein wichtiger Punkt beim Kauf des Geräts Monessen Hearth GRUF Series (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Monessen Hearth GRUF Series noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Monessen Hearth GRUF Series - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Monessen Hearth GRUF Series reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Monessen Hearth GRUF Series erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Monessen Hearth GRUF Series besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Monessen Hearth GRUF Series verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Monessen Hearth GRUF Series. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Monessen Hearth GRUF Series gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.