Benutzeranleitung / Produktwartung C2801VF des Produzenten Monessen Hearth
Zur Seite of 28
READ AND SA VE THESE INSTRUCTIONS MODELS: C2801VF , C2802VF , C2803VF , and C2804VF Natural Gas or Propane/LPG Milli-V olt Control UNVENTED GAS CAST IRON ST OVE INST ALLA TION AND OPERA TING INSTRUCTIONS This is an unvented gas-fired heater .
2 45D0080 45D0080 3 CONTENTS Important Safety Information .............................. 3 Product Features ................................................ 5 Getting Started ................................................... 6 Product Specifications .
2 45D0080 45D0080 3 9. The installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.l/NFP A54. 10. This unit complies with ANSI Z21.11.2-2001 Un vented Heaters. 11. Do not install heater in a bathroom or bedroom.
4 45D0080 45D0080 5 IMPORT ANT SAFETY INFORMA TION Continued fr om page 3 15. This is an un vented gas-red heater . It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be pro- vided.
4 45D0080 45D0080 5 PRODUCT FEA TURES Off/Pilot/On Knob Hi/Lo Knob Data and Instruction Plates Door Figure 1 - Cast Iron Stove Optional Remote Receiver Optional Thermostat Sensor O.
6 45D0080 45D0080 7 GETTING ST ARTED MAKE SURE YOU HA VE RECEIVED ALL P ARTS: Check your packing list to verify that all listed parts ha ve been recei ved.
6 45D0080 45D0080 7 PRODUCT SPECIFICA TIONS NA TURAL GAS NOTE: An external regulator is required to reduce supply pressure to a maximum of 10 1 / 2 " w .c. on Natural Gas systems operating at higher pressure. MILLIVOL T PRESSURE Regulator Pressure Setting: 3.
8 45D0080 45D0080 9 CODES Adhere to all local codes or , in their absence, the latest edition of THE NA TION AL FUEL GAS CODE ANSI Z223.1 or NFP A54 which can be obtained from… American National Standards Institute, Inc. 1430 Broadway Ne w Y ork, NY 10018 or National Fire Pr otection Association, Inc.
8 45D0080 45D0080 9 The follo wing formula can be used to determine the maximum heater rating per the denition of unconned space: BTU/Hr = (L 1 + L 2 ) Ft x (W) Ft x (H) Ft 50 Consider two connecting rooms with an open area between, with the follo wing dimensions: L 1 = 15 1 / 2 Ft.
10 45D0080 45D0080 1 1 .
10 45D0080 45D0080 1 1 Pipe Coupling T o Heater V alve Gas Supply Inlet CONNECTING THE GAS NOTICE: A qualified gas appliance installer must connect the heater to the gas supply . Consult all local codes. IMPORT ANT : Hold heater v alve rmly with a wrench to pre vent mov ement when connecting to inlet pipe.
12 45D0080 45D0080 13 CHECKING GAS PRESSURE AND CONNECTING REMOTE RECEIVER The heater gas inlet connection is 3/8" NPT at the valve. The inlet is located on left side of sto ve. Remo ve front control plate to better access the inlet.
12 45D0080 45D0080 13 ELECTRICAL WIRING (MILLI-VOL T) The milli-volt v alve is a self-po wered combination gas control THA T DOES NOT REQUIRE 1 10 V AC T O OPERA TE. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
14 45D0080 45D0080 15 .
14 45D0080 45D0080 15 4. Remove adhesi ve backing from plastic clip. Press clip to bottom of v alve.
16 45D0080 45D0080 17 Log #4 Log #2 Log #1 Log #3 Back Pins Front Pins LOG PLACEMENT INST ALLING LOGS ON GRA TE (See Figure 12) 1. Install back log (#1) on two pins located near the back of base. Check log position and stability . 2. Install center log (#2) on two pins located near the front of the base.
16 45D0080 45D0080 17 Glowing Embers Figure 15 - Correct appearance of Embers and Rear Flame FLAME APPEARANCE Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition, periodically check the ames visually during operation.
18 45D0080 45D0080 19 Figure 16 - Location of Piezo Ignitor , Control Knobs and Switch on Milli-volt Unit A. This appliance is equipped with an ignition de vice which automatically lights the pilot.
18 45D0080 45D0080 19 OPERA TING INSTRUCTIONS 1. STOP! Read the safety information label. 2. Make sure the manual shutof f v alve is fully open. 3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot.
20 45D0080 45D0080 21 1. Open stov e door . Remo ve any items necessary for easy access to the pilot (for e xample: logs, screens, etc.). 2. Follo w appropriate lighting instructions found previously . Light a match and hold the ame to the end of the pilot and ignite the pilot.
20 45D0080 45D0080 21 REPLACEMENT P ARTS ARE A V AILABLE THROUGH YOUR RET AILER. Item Description Qty 1 Back Log 1 44D101 1K 2 Middle Log 1 45D0502K 3 Front Log 1 44D1012K 4 T op Log 1.
22 45D0080 45D0080 23 REPLACEMENT P ARTS Failure to position the parts in accordance with these diagrams or failure to use only parts specifically a p p r o v e d w i t h t h i s a p p l i a n c e m a y result in property damage or personal injury .
22 45D0080 45D0080 23 REPLACEMENT P ARTS LIST REPLACEMENT P ARTS ARE A V AILABLE THROUGH YOUR RET AILER. C2801/02/03/04VF BURNER ASSEMBL Y Accessories Flex Connector Flexcon 30 Wall Switch Kit MVWS Wa.
24 45D0080 45D0080 25 OBSERVED PROBLEM When ignitor button is pressed, there is no spark at ODS/pilot. App li a nc e p ro du c es u nw an t ed odors. Appliance shuts off during use. Ga s odor ev en wh en co ntr ol kn ob is in OFF position. When ignitor button is pressed, there is spark at ODS pilot, but no ignition.
24 45D0080 45D0080 25 OBSERVED PROBLEM ODS/pilot lights, but flame goes out when control knob is released. Bur ner does no t l ight afte r OD S/ pilot is lit. Burner backres during com- bustion. Slight smoke or odor during initial operation. Logs appear to smoke after ini- tial operation.
26 45D0080 45D0080 27 NOTES.
26 45D0080 45D0080 27 NOTES.
April 2002 P/N 45D0080 • Rev . 1 LEXINGT ON FORGE LIMITED LIFETIME W ARRANTY POLICY LIFETIME W ARRANTY The follo wing components are warranted for life to the original owner , subject to proof of purchase: Firebox, Combustion Chamber , Heat Exchanger , Grate and Stainless Steel Burners.
Ein wichtiger Punkt beim Kauf des Geräts Monessen Hearth C2801VF (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Monessen Hearth C2801VF noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Monessen Hearth C2801VF - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Monessen Hearth C2801VF reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Monessen Hearth C2801VF erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Monessen Hearth C2801VF besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Monessen Hearth C2801VF verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Monessen Hearth C2801VF. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Monessen Hearth C2801VF gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.