Benutzeranleitung / Produktwartung 624WBPF des Produzenten Monessen Hearth
Zur Seite of 32
539042 MPL cov er Installation, Operation and Maintenance Manual for Residential Installation .
2 624WBPF W oodbur ning Fireplace 53D9052 Y ou have chosen the finest wood burning fireplace available. Y our fireplace has been designed for years of heating and viewing enjoyment. Please take time to read this entire manual before installing or operating your fireplace.
3 53D9052 624WBPF W oodbur ning Fireplace 1. Read these instructions entirely before beginning any part of the installation. Save these instructions for any future repairs. 2. Use these instructions as a guide during the installation of the fireplace.
4 624WBPF W oodbur ning Fireplace 53D9052 When an AK4 combustion air assembly and a combustion air duct are attached to the connecting point on the left or right side of the fireplace, combustion air may enter the firebox through a dam- pered opening behind the left or right side brick.
5 53D9052 624WBPF W oodbur ning Fireplace 36 56O ” (927 mm) 1/2” (13 mm) 30 56M ” (768 mm) 37 56M ” (946 mm) 42” (1067 mm) 45 6M ” (1 162 mm) 36” (914 mm) 38” (965 mm) 23” (584 mm.
6 624WBPF W oodbur ning Fireplace 53D9052 This fireplace does not require any special foundation. If the fireplace is to be trimmed with large stone or brick facing, an adequate foundation is required to support these materials.
7 53D9052 624WBPF W oodbur ning Fireplace FP2345 MPL featur es Figure 3 Residential Installation Chimney Cap Roof Flashing (Flue Outlet Height) Storm Collar 14 ft. = Min. Height (No offsets) 14 ft. = Min. Height (2 30° Elbows) 21 ft.
8 624WBPF W oodbur ning Fireplace 53D9052 Survey the planned location for the fireplace for overhead plumbing or electrical wires, etc., that might complicate the installation or endanger persons installing or cleaning the chimney .
9 53D9052 624WBPF W oodbur ning Fireplace If this fireplace is installed on a combustible floor , the floor area 16 inches in front of, and 8 inches ei- ther side of the fireplace opening must be protected by an insulating noncombustible hearth extension.
10 624WBPF W oodbur ning Fireplace 53D9052 WH36 Glass Doors (Standard) Chimney Support 11CS 30° Elbow Set 11CF30-2 Hearth Extension Kit H1652 Firestop Spacer FS2A, FS6A Flashing 8-6-12, 8-12-12 AK4 C.
1 1 53D9052 624WBPF W oodbur ning Fireplace Unpack and check the fireplace and chimney for damage. If any items have been damaged, report this to your dealer . Before beginning the installation, be sure you have the proper parts in sufficient quantity .
12 624WBPF W oodbur ning Fireplace 53D9052 FP 548b SHR 5/1 1/99 djt Angle of Chimney at Ceiling Size of Chimney V ertical 30˚ 1 1" .
13 53D9052 624WBPF W oodbur ning Fireplace 1. Lay out, cut and frame openings through all ceilings and the roof at the point where the chimney will pass through.
14 624WBPF W oodbur ning Fireplace 53D9052 1. Determine the location and amount of of fset required, then select the combinations of chimney sections and elbows required from the offset chart.
15 53D9052 624WBPF W oodbur ning Fireplace 0 0 0 0 0 3" 1 1".
16 624WBPF W oodbur ning Fireplace 53D9052 The proper height as previously explained is important to assure proper draft and safety . The chim- ney cap extends the flue outlet four inches above the top of the last section of chimney .
17 53D9052 624WBPF W oodbur ning Fireplace 1. Extend the regular chimney sections until the top of the chimney is 4” below the total flue height desired. Do not snap the last section of inlet air duct or largest diameter pipe in place until Step 3 is completed.
18 624WBPF W oodbur ning Fireplace 53D9052 (continued) 1. Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly should be avoided.
19 53D9052 624WBPF W oodbur ning Fireplace 1 2 3 2“ App. FP1906 Duct connector 8/08 Lo op D is eng age d Cl am p A ro un d Du ct S.
20 624WBPF W oodbur ning Fireplace 53D9052 Improper installation or operation of a gas appli.
21 53D9052 624WBPF W oodbur ning Fireplace FP2356 gas line installation 4” When using a gas appliance, the fireplace damper must be set in fully open position. Figure 26 Outer Fireplace Wrap Inner Fireplace Wrap Side Brick 24” Max.
22 624WBPF W oodbur ning Fireplace 53D9052 FP2358 finish install 1/2” Min. Air Space to Combustibles 2 x 4 Stud W allboard Corner Post Nailing Flange FP2358 Figure 27 .
23 53D9052 624WBPF W oodbur ning Fireplace If a decorative gas appliance is used in the fireplace the fireplace damper must be fixed in an open position. (See additional operation information in section titled “Operation Guide- lines”.
24 624WBPF W oodbur ning Fireplace 53D9052 Y ou’ll need a minimum of three logs, preferably four , to make a good fire. Add kindling and new logs as needed to rekindle a dying fire. New logs should be added at the rear grate after raking the coals toward the front.
25 53D9052 624WBPF W oodbur ning Fireplace Wood can be dried sufficiently for burning within a few weeks if protected form rain in a low humid- ity area.
26 624WBPF W oodbur ning Fireplace 53D9052 At the end of each heating season or when the fireplace will not be in use for an extended time, the ashes should be removed and the hearth area should be swept as clean as is practical.
27 53D9052 624WBPF W oodbur ning Fireplace 1. Don’t allow other installations or operation considerations to take priority over safety considerations. 2. Don’t attempt to use the fireplace until the installation is complete.
28 624WBPF W oodbur ning Fireplace 53D9052 1 2 3 4 5 6 7a,b,c 8 9 10 1 1 12 13a,b,c 1 1 1 539042 MPL parts 1.
29 53D9052 624WBPF W oodbur ning Fireplace.
30 624WBPF W oodbur ning Fireplace 53D9052.
31 53D9052 624WBPF W oodbur ning Fireplace (except blowers) .
APRIL 2009 53D9042 • Rev . 3 149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com.
Ein wichtiger Punkt beim Kauf des Geräts Monessen Hearth 624WBPF (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Monessen Hearth 624WBPF noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Monessen Hearth 624WBPF - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Monessen Hearth 624WBPF reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Monessen Hearth 624WBPF erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Monessen Hearth 624WBPF besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Monessen Hearth 624WBPF verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Monessen Hearth 624WBPF. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Monessen Hearth 624WBPF gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.