S-62 & S-64 Processes Description MIG (GMA W) W elding Flux Cored (FCA W) W elding (Gas- and Self-Shielding) Submerged (SAW) W elding Wire Feeder (Use with CV Power Sources) OM-1579 133 566V September 2001 Visit our website at www.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
dec_con 1 1/96 Declaration of Conformity for European Community (CE) Products This information is provided for units with CE certification (see rating label on unit). Note Manufacturer ’ s Name: Miller Electric Mfg. Co. Manufacturer ’ s Address: 1635 W .
OM-1579 Page 1 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING som _nd_4/98 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message.
OM-1579 Page 2 Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld. ARC RA YS can burn eyes and skin. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.
OM-1579 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring – be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-1579 Page 4 1-5. EMF Information Considerations About W elding And The Effects Of Low Frequency Electric A n d M a g netic Fields W elding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields.
OM-1579 Page 5 SECTION 1 – CONSIGNES DE SECURITE – LIRE A V ANT UTILISA TION som _nd_fre 4/98 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette proc é dure pr é sente des risques de danger ! Ceux-ci sont identifi é s par des symboles adjacents aux directives.
OM-1579 Page 6 Le rayonnement de l ’ arc du proc é d é de soudage g é n è re des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provoquer des br û lures dans les yeux et sur la peau. Des é tincelles sont projet é es pendant le soudage.
OM-1579 Page 7 1-3. Dangers suppl é mentaires en relation avec l ’ installation, le fonctionnement et la maintenance Risque D ’ INCENDIE OU D ’ EXPLOSION. D Ne pas placer l ’ appareil sur , au-dessus ou à proxi- mit é de surfaces infllammables.
OM-1579 Page 8 1-4. Principales normes de s é curit é Safety in W elding and Cutting, norme ANSI Z49.1, de l ’ American Wel- ding Society , 550 N.W . Lejeune Rd, Miami FL 33126 Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.
OM-1579 Page 9 SECTION 2 – DEFINITIONS 1 1.1 1.2 1.3 3 3.1 3.2 3.3 4 4.1 + 2 2.1 2.2 + + 56 + 2.3 S-178 936 A. W arning! W atch Out! There are possible hazards as shown by the symbols. B. Drive rolls can injure fingers. C. W elding wire and drive parts are at welding voltage during operation – keep hands and metal objects clear .
OM-1579 Page 10 ST-178 794-A 50/60 S/N: 24 10.0 Hz 50/60 IP 21 V 100 A 750 X 100 % V U 1 = A I 1 = 1 U 2 = I 2 = 2-2. Rating Label For CE Products For label location see Section 4-4. 2-3. Symbols And Definitions Some symbols are found only on CE products.
OM-1579 Page 1 1 SECTION 3 – INTRODUCTION 3-1. Specifications T ype of Input Power W elding Power Source T ype Wire Feed Speed Range Wire Diameter Range W elding Circuit Rating IP Rating Overall Dim.
OM-1579 Page 12 4-2. Gun Recommendation T able Process Gun GMA W – Hard or Cored Wires Roughneck C-Series Guns: 300, 400, 500, And 600 Amp. FCA W – Self-Shielding Wires FC-1260 Or FC-1 150 4-3.
OM-1579 Page 13 4-4. Rear Panel Connections And Rotating Drive Assembly Ref. ST-152 462-C / ST -156 930-A 1 2 7 3 5 6 1 Customer Supplied Gas Hose 2 Shielding Gas V alve Fitting Requires fitting with 5/8-18 right- hand threads.
OM-1579 Page 14 4-5. 14-Pin Plug Information Pin* Pin Information A 24 volts ac with respect to socket G. B Contact closure to A completes 24 volts ac contactor control circuit. A J G Circuit common for 24 volts AC circuit. A J B K I C +10 volts dc output to remote control with respect to socket D.
OM-1579 Page 15 4-8. Installing And Threading Welding Wire . Be sure that outlet cable has proper size liner for the welding wire size. When installing gun, position liner extending from outlet wire guide as close as pos- sible to drive rolls without touching.
OM-1579 Page 16 802 479 / Ref. SA-146 866-B / Ref. SA-148 666-E / Ref. SA-150 588-D T ools Nee d e d : . If wire feeder is equipped with a voltage sensing lead, set DIP switch S3 to the OFF position (up). If wire feeder is NOT equipped with a voltage sensing lead, set DIP switch S3 to the ON position (down).
OM-1579 Page 17 SECTION 5 – OPERA TION 5-1. Front Panel Controls ST-151 845-B 1 V oltmeter (Optional) (See Section NO T AG) 2 Wire Speed Meter (Optional) Factory set to display inches per minute. If display of meters per minute is desired, see Section 4-9.
OM-1579 Page 18 5-2. Overload Protection And Optional Side Panel Controls 802 418-A 1 Circuit Breaker CB1 CB1 protects wire feed motor from overload. Press to reset. 2 Preflow Control Control sets time gas flows before welding wire is energized. 3 Spot Time Control Factory set for 0 to 5 seconds of spot time.
OM-1579 Page 19 6-2. T roubleshooting Y Disconnect power before troubleshooting T rouble Remedy Wire feeds, shielding gas flows, but electrode wire is not energized. Check interconnecting cord connections. If secure, check cord for continuity and repair or replace (see Sections 4-3 and 4-4).
OM-1579 Page 20 SECTION 7 – ELECTRICAL DIAGRAM Figure 7-1.Circuit Diagram.
OM-1579 Page 21 196 503 – A.
OM-1579 Page 22 SECTION 8 – P ARTS LIST Fig 8-4 Fig 8-2 1 2 3 4 5 7 8 9 6 7 10 11 12 18 14 19 22 23 24 25 26 27 6 20 21 ST-136 987-K 13 15 16 17 18 .
OM-1579 Page 23 Description Part No. Item No. Figure 8-1. Main Assembly Quantity 1 141 753 HUB & SPINDLE ASSEMBL Y , (consisting of) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 058 427 RING, retaining spool 1 .
OM-1579 Page 24 Ref. ST-142 438-G *See option that is applicable 1 2 4 3 * 5 6 7 Fig 8-3 8 9 11 12 13 14 15 20 19 18 17 16 21 22 23 24 25 9 26 10 29 30 * 28 31 27 .
OM-1579 Page 25 Description Part No. Dia. Mkgs. Item No. Figure 8-2. Control Box (Fig 8-1 Item 14) Quantity 1 RC6 048 282 CONNECTOR w/SOCKETS 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 S31 ♦ 134 847 SWITCH, tgl SPDT 15A 125V AC 1 .
OM-1579 Page 26 Description Part No. Dia. Mkgs. Item No. Figure 8-2. Control Box (Fig 8-1 Item 14) Quantity ♦♦ 173 750 DIGIT AL DUAL SCHEDULE, (consisting of) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 134 209 NUT , .
OM-1579 Page 27 Description Part No. Dia. Mkgs. Item No. Figure 8-3. Control Panel (Fig 8-2 Item 7) Quantity 1 S32 ♦ 01 1 770 SWITCH, tgl SPDT 6A 125V AC 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-1579 Page 28 See T able 8-1 For Drive Roll & Wire Guide Kits . Hardware is common and not available unless listed. 802 458 Figure 8-4. Drive Assembly , Wire.
OM-1579 Page 29 Description Part No. Dia. Mkgs. Item No. Figure 8-4. Drive Assembly , Wire (Fig 8-1 Item 23) Quantity 2 Drive Roll 4 Drive Roll 1 010 668 SCREW , cap stl sch .250-20 x 1.500 2 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-1579 Page 30 .023-.025 in. 0.6 mm 151 030 151 024 087 130 .030 in. 0.8 mm 151 031 151 025 053 695 .035 in. 0.9 mm 151 032 151 026 053 700 151 044 151 036 072 000 151 061 151 052 132 958 .045 in. 1.1/1.2 mm 151 033 151 027 053 697 151 045 151 037 053 701 151 062 151 053 132 957 151 077 151 070 083 489 .
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 7/00 Y o ur distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor .
PRINTED IN USA 2000 Miller Electric Mfg. Co. 6/00 Miller Elect ric Mfg. Co. An I l li noi s T ool Works Com pany 1635 W est S pencer St reet Applet on, WI 54914 USA International He adquarters –.
Ein wichtiger Punkt beim Kauf des Geräts Miller Electric S-62 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Miller Electric S-62 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Miller Electric S-62 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Miller Electric S-62 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Miller Electric S-62 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Miller Electric S-62 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Miller Electric S-62 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Miller Electric S-62. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Miller Electric S-62 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.