Benutzeranleitung / Produktwartung 394F des Produzenten Miller Electric
Zur Seite of 44
Axcess Dual W ire Feeder Processes Description MIG (GMA W) W elding Flux Cored (FCA W ) Welding (Gas- And Self-Shielded) Wire Feeder OM-222 394F 2006 − 08 ™ File: Advanced Manufacturing Systems V isit our website at www.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
OM-222 394 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _3/05 Y W arning: Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.
OM-222 394 Page 2 Arc rays from the w elding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin.
OM-222 394 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-222 394 Page 4 1-5. Principal Safety Standards Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www .
OM-222 394 Page 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION som _3/05 Y A vertissement : se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
OM-222 394 Page 6 Le rayonnement de l’arc du procédé de soudage génère des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provo- quer des brûlures dans les yeux et sur la peau. Des étincelles sont projetées pendant le soudage.
OM-222 394 Page 7 2-3 . Dangers s uppléme ntaires e n rela t ion avec l’ins tallation, le fonctionnement et la m a intenance Risque D’INCENDIE OU D’EXPLO- SION. D Ne pas placer l’appareil sur , au-dessus ou à proximité de surfaces inflammables.
OM-222 394 Page 8 2-5. Princi pales n ormes de sécu rit é Safety in W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site In- ternet : www .
OM-222 394 Page 9 SECTION 3 − INTRODUCTION 3-1. Specifications T ype of Input Power W elding Power Source T ype Wire Feed Speed Range Wire Diameter Range W elding Circuit Rating Overall Dimensions W eight 40 V olts DC 10 Amperes Axcess Series Standard: 40 T o 1400 ipm (1.
OM-222 394 Page 10 804 019-A 1 W elding Power Source 2 Wire Feeder 3 Gas Cylinder 4 Gas Hose 5 Network Feeder Cable 6 Negative ( − ) Weld Cable 7 W orkpiece 8 V oltage Sensing Lead Recommended for Accu-pulse a nd RMD (optional). . Positive (+) voltage sensing lead is contained in the motor cable.
OM-222 394 Page 1 1 4-3. Rear Panel Connections And Rotating Drive Assembly 804 020-A / 802 825-A 1 9-Pin Network Receptacle 2 Power Switch 3 Shielding Gas V alve Fitting (Left And Right) Requires fitting with 5/8-18 right- hand threads. Connect customer- supplied gas hose.
OM-222 394 Page 12 4-4. 9-Pin Network Receptacle Information 9 Pin Pin Information A Capacitor C1 to ground B Shield G F C V olt sense H G E F D Can low I H D E E Can high A B I C D F +24 volts dc common B C G + 24 volts dc H Motor voltage +40 volts dc common I Motor voltage +40 volts dc 4-5.
OM-222 394 Page 13 4-6. Installing And Threading Welding Wire Ref. 156 929-A / Ref. 150 922 / Ref. 156 930 / 802 954 / S-0627-A T ools Needed: . Be sure that outlet cable has proper size liner for the welding wire size. When installing gun, position liner extending from outlet wire guide as close as possible to drive rolls without touching.
OM-222 394 Page 14 4-7. Power Source Display At Power Up 1 Upper Display 2 Lower Display Program Process Wire T ype Gas T ype T rigger Control Adjust V olts Time WFS Amps Process Set Up Feeder Set Up .
OM-222 394 Page 15 SECTION 5 − OPERA TION 5-1. Operational T erms The following is a list of terms and their definitions as they apply to the interface unit in the wire feeder: General T erms: Arc Adjust T erm used to represent arc length adjustments in pulse programs.
OM-222 394 Page 16 General T erms: Sequence Selecting Sequence will allow setting of preflow , start, crater , and postflow times and parameters. Preflow Setting a time value for gas flow prior to arc start.
OM-222 394 Page 17 SECTION 6 − OPERA TION 6-1. Power Switch 1 Power Switch 804 021-A 1 1 Left/Right Select Switch Pressing the Left/Right Select switch allows the operator to choose which side of the units’ con- trols will operate. 6-2. Left/Right Select Switch 804 022-A .
OM-222 394 Page 18 6-3. Jog/Purge The Jog/Purge switch provides the following functions: • Pressing left side of the Jog/Purge switch allows the operator to feed wire without energizing the weld power or gas valve circuit. The wire will feed at a 60 ipm rate for 3 seconds, then the rate ramps up to 700 ipm until the Jog switch is released.
OM-222 394 Page 19 6-4. Front Panel Sections See Section 6-6 See Section 6-7 See Section 6-10 See Section 6-9 See Section 6-8 See Section 6-5 Program Process Wire T ype Gas T ype T rigger Control Adju.
OM-222 394 Page 20 6-5. Program Push Button 1 3 Program 2 1 Program Display The number of the active program is displayed. 2 Program Push Button 3 Program Push Button LED The LED lights to indicate that programs can be changed using the Adjust knob. Momentarily pres s button to illuminate LED.
OM-222 394 Page 21 6-7. Lower Display 1 Lower Display The lower display shows WFS (wire feed speed), AMPS (amperage), ARC CTL (arc control), or Time. The feeder displays only preset wire speed at idle (not welding). While welding, the average amperage is displayed.
OM-222 394 Page 22 6-8. Feeder Set Up Push Button 1 Feeder Set Up Push Button LED 2 Feeder Set Up Push Button • Press button to choose Sequence. Feeder Set Up push-button LED will illuminate. 3 Sequence LED • When the Feeder Set Up button is pressed once, the Sequence LED will illuminate and the upper display will show sequence options.
OM-222 394 Page 23 6-10. Process Set Up Push Button • Press the Process Set Up push button the first time will illuminate the button LED and the Process LED. The upper and lower displays will be used for Accu-pulse and only the lower display for MIG, Pulse and RM D (optional) to show the current process installed in this program.
OM-222 394 Page 24 6-1 1. Reset Mode 198 993 / 803 246-B . Reset mode is not active when Program Lock is enabled. Th e reset mode allows the operator to reload factory program settings for all eight active programs in the unit. . System configuration data will be lost during the Reset operation.
OM-222 394 Page 25 SECTION 7 − SETTING SEQUENCE P ARAMETERS 7-1. Sequence Parameters In A Program . For more information on Sequence mode, see Feeder Set Up Push Button in Section 6-8 . We ld Time can only be set by using an o ptional PDA with File Management/WaveWriter softwar e.
OM-222 394 Page 26 SECTION 8 − MAINTENANCE 8-1. Routine Maintenance Y Disconnect power before maintaining. . Maintain more often during severe conditions.
OM-222 394 Page 27 8-2. Diagnostics ERR T ACH • The tach error occurs 2 seconds after the loss of tachometer feedback. The motor speed is reg ula ted through the monitoring of voltage and current. Press Jog/Purge button to clear error . ERR MOTR • The motor error indicates that the motor has been drawing too much current for too long.
OM-222 394 Page 28 8-2. Diagnostics (Continued) WELD W AIT • The weld wait erro r indicates unit was not ready for a weld sequence. Press Jog/ Purge button to clear error . MOTR COM • The motor communication erro r indi- cates motor board lost data communica- tions.
OM-222 394 Page 29 8-3. T roubleshooting Y Disconnect power before troubleshooting T rouble Remedy Wire feeds, shielding gas flows, but electrode wire is not energized. Check and secure weld cable connections (see Section 4-2). Electrode wire feeding stops or feeds erratically during welding Check gun trigger connection.
OM-222 394 Page 30 SECTION 9 − ELECTRICAL DIAGRAM Figure 9-1. Circuit Diagram.
OM-222 394 Page 31 218 564-D.
OM-222 394 Page 32 SECTION 10 − P ARTS LIST 804 023-A . Hardware is common and not available unless listed. 12 19 2 1 3 17 18 7 16 8 11 9 10 6 20 15 11 10 14 5 22 4 − Figure 10-3 21 − Figure 10-2 9 13 Figure 10-1.
OM-222 394 Page 33 Description Part No. Item No. Figure 10-1. Main Assembly Quantity 1 159 647 INSULA TOR, motor clamp 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 159 646 CLAMP , motor base 2 .
OM-222 394 Page 34 804 024-C . Hardware is common and not available unless listed. 1 2 4 5 6 3 7 8 9 10 12 11 14 15 16 17 13 18 19 11 21 20 22 23 24 25 26 27 28 29 Figure 10-2. Control Box Description Part No. Dia. Mkgs. Item No. Figure 10-2. Control Box (Figure 10-1 Item 21) Quantity 1 +220 321 WRAPPER, feeder dual Axcess 1 .
OM-222 394 Page 35 Description Part No. Dia. Mkgs. Item No. Figure 10-2. Control Box (Figure 10-1 Item 21) (Continued) Quantity 19 030 170 BUSHING, snap − in nyl .750 ID x 1.000 mtg hole 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-222 394 Page 36 See T able 10-1 For Drive Roll & Wire Guide Kits . Hardware is common and not available unless listed. 802 950-B 9 29 28 35 30 31 32 27 34 26 33 23 22 25 24 21 1 4 3 2 5 6 8 7 4 5 1 2 3 6 16 15 20 10 15 13 18 11 12 14 19 18 17 Figure 10-3.
OM-222 394 Page 37 Description Part No. Dia. Mkgs. Item No. Figure 10-3. Drive Assembly , Wire (Figure 10-1 Item 4) (continued) Quantity 22 168 825 DRIVE, pinion 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notes.
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2006 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
PRINTED IN USA © 2006 Miller Electric Mfg. Co. 2006 − 01 Miller Elect ric Mfg. Co. An Illinois T ool Wor k s Comp any 1635 W es t Spencer St reet Applet on, WI 5 4914 USA International He adquarter.
Ein wichtiger Punkt beim Kauf des Geräts Miller Electric 394F (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Miller Electric 394F noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Miller Electric 394F - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Miller Electric 394F reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Miller Electric 394F erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Miller Electric 394F besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Miller Electric 394F verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Miller Electric 394F. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Miller Electric 394F gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.