Benutzeranleitung / Produktwartung 22A des Produzenten Miller Electric
Zur Seite of 32
Processes Description MIG (GMAW) W elding Flux Cored (FCA W ) W elding Wire Feeder OM-193 472N 2006 − 05 22A, 24A V isit our website at www.MillerWelds.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
OM-193 472 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _3/05 Y W arning: Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown i n the adjoining symbols.
OM-193 472 Page 2 Arc rays from the w elding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin.
OM-193 472 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-193 472 Page 4 1-5. Principal Safety Standards Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www .
OM-193 472 Pa ge 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION som _3/05 Y A vertissement : se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
OM-193 472 Page 6 Le rayonnement de l’arc du procédé de soudage génère des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provo- quer des brûlures dans les yeux et sur la peau. Des étincelles sont projetées pendant le soudage.
OM-193 472 Pa ge 7 2-3 . Dange rs suppléme ntaire s en r e lation avec l’installa tion, le f onc tionneme nt e t l a maintenance Risque D’INCENDIE OU D’EXPLO- SION. D Ne pas placer l’appareil sur , au-dessus ou à proximité de surfaces inflammables.
OM-193 472 Page 8 2-5. Princi pales nor mes de sécur ité Safety in W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site In- ternet : www .
OM-193 472 Page 9 SECTION 3 − INST ALLA TION 3-1. Specifications T ype of Input Power W elding Power Source T ype Wire Feed Speed Range Wire Diameter Range W elding Circuit Rating Overall Dimensions W eight 24 V olts AC Single Phase 7 Amperes 50/60 Hz Constant V oltage (CV) DC With 14-Pin And Contactor Control 75 to 750 ipm (1.
OM-193 472 Page 10 3-3. Gun Recommendation T able Process Gun GMA W − Hard or Corded Wires M25 Or M40 FCA W − Self-Shielding Wires GA-40GL 1 CV Welding Power Source With 24 V AC Power 2 CV Welding Power Source Without 24 V AC Power 3 1 15 V olts AC /24 V olts AC Power Adapter 4 14-Pin Control Cord 5 Weld Cable (Required) 6 W ork 3-4.
OM-193 472 Page 1 1 3-6. 14-Pin Plug Information Pin* Pin Information A 24 volts ac with respect to pin G. A J K B Contact closure to A completes 24 volts ac contactor control circuit. A J B K I G Circuit common for 24 volts AC circuit. B C L N H C +10 volts dc output to remote control with respect to pin D.
OM-193 472 Page 12 3-8. Optional Meter Circuit Board Settings Ref. 802 357 / Ref. 186 266 T ools Needed: 1/4 in 1 Meter Circuit Board 2 DIP Switch S2 Set DIP switch S2 for type of welding power source, and desired wire feed speed display (see illustration).
OM-193 472 Page 13 3-9. Motor Start/Burnback Control Ref. 802 357 / 192 653 T o change wire feed starting speed proceed as follows: T urn Off unit and welding power source. Remove wrapper . 1 Motor Board PC1 2 Motor Start Control Potentiometer R73 Remove protective white rubber cap before making adjustment.
OM-193 472 Page 14 3-10. Installing Wire Guide And Drive Roll 801 923-C Install and secure inlet wire guide on either assembly , and intermediate wire guide on 4 drive roll assembly only . Install drive rolls and turn drive roll nut one click. During maintenance intervals, remove drive rolls, and clean grooves using a wire brush.
OM-193 472 Page 15 3-1 1. Installing And Threading W elding Wire T ools Needed: 1 Retaining Ring 2 Hub T ension Adjustment Nut If necessary , move hub on support for use of different size wire spool. Remove retaining ring, and install spool so hub pin fits spool hole.
OM-193 472 Page 16 SECTION 4 − OPERA TION 4-1. Front Panel Controls 1 Optional V oltage/Wire Speed Meter 2 Optional V oltage/Wire Speed Switch Use to choose volts or wire feed speed display . 3 Optional Remote V oltage Control Use to set welding power source voltage at the wire feeder .
OM-193 472 Page 17 4-2. Optional Side Panel Controls Ref. 802 357-A / Ref. 186 589 / 210 436-A 1 Preflow Control Control sets time gas flows before welding wire is energized. T ime range is 0 to 5 seconds. 2 Postflow Control Control sets time gas flows after completion of burnback.
OM-193 472 Page 18 5-2. Overload Protection Y T urn Off wire feeder and welding power source. Stop engine on welding generator . 1 Circuit Breaker CB1 CB 1 protects wire feeder from over- load. Correct problem and manually reset breaker . 802 349-A 1 5-3.
OM-193 472 Page 19 SECTION 6 − ELECTRICAL DIAGRAM 210 430-A Figure 6-1. Circuit Diagram For Wire Feeder With Optional Equipment.
OM-193 472 Page 20 SECTION 7 − P ARTS LIST Figure 7.1. Main Assembly 802 358-F . Hardware is common and not available unless listed. 10 Figure 7-2 & Figure 7-3 38 40 39 33 35 36 34 32 31 30 37 4.
OM-193 472 Page 21 Figure 7-1. Main Assembly Diagram marking Item No. Part No. Description Quantity 1 089 899 LA TCH 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-193 472 Page 22 Diagram marking Item No. Part No. Description Quantity Figure 7-1. Main Assembly (Continued) ♦ 1 15 443 ST AND-OFF , 6-32 x .750 lg 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-193 472 Page 23 Diagram marking Item No. Part No. Description Quantit y Figure 7-2. Drive Assembly , Wire (2 Drive Roll) (Fig 7-1 Item 40) 1 602 009 SCREW , .250-20 x 1.250 soc hd hex gr 8 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-193 472 Page 24 Diagram marking Item No. Part No. Description Quantity Figure 7-3. Drive Assembly , Wire (4 Drive Roll) (Fig 7-1 Item 40) 1 602 009 SCREW , .250-20 x 1.250 soc hd hex gr 8 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-193 472 Page 25 T able 7-1. Drive Roll And Wire Guide Kits (2 Drive Roll) Base selection of drive rolls upon the following recommended usages: 1. V -Grooved rolls for hard wire. 2. U-Grooved rolls for soft and soft shelled cored wires. 3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).
OM-193 472 Page 26 T able 7-2. Drive Roll & Wire Guide Kits (4 Drive Roll) Base selection of drive rolls upon the following recommended usages: 1. V -Grooved rolls for hard wire. 2. U-Grooved rolls for soft and soft shelled cored wires. 3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2006 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
PRINTED IN USA © 2006 Miller Electric Mfg. Co. 2006 − 01 Miller Elect ric Mfg. Co. An Illinois T ool W orks Compa ny 1635 West S pencer S treet Applet on, WI 5 4914 US A International He adquarters.
Ein wichtiger Punkt beim Kauf des Geräts Miller Electric 22A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Miller Electric 22A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Miller Electric 22A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Miller Electric 22A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Miller Electric 22A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Miller Electric 22A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Miller Electric 22A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Miller Electric 22A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Miller Electric 22A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.