Operation and Installation Instructions 691 LOCK SYSTEM READ GENERAL INSTALLATION GUIDELINES SHEET (FORM NO. 81-600-001) BEFORE PROCEEDING. 1. The MICO 691 System is a supplemental safety device which provides additional brake holding action when used with existing vehicle parking brake .
Page SELF ADHESIVE LABELS ................................. 1 INTRODUCTION ...................................... 2 PRINCIPLE OF OPERATION ................................ 2 INSTALLING A 691 SYSTEM ................................ 3 IDENTIFY YOUR BRAKE SYSTEM .
1 THI S N O TI C EM U S T BE AFFIXED O ND A S HI N V I E W O F O PERA T O R Operator must read and understand W arnings and Operating Instructions before using vehicle (Form no. 81-690-032). 691 Brake Loc k T O LOCK: 1. Set parking brake 2. Move lock s witch to LOCK position T O RELEASE: 1.
2 Vehicles today have two separate brake systems. One is the service brake system and the other is the parking brake system. The service brake system is used to slow or stop a vehicle during normal operation. The parking brake system is usually cable operated and used to hold the vehicle stationary while parked.
3 There are four steps to installing the 691 System. 1. Mounting 2. Plumbing 3. Wiring 4. Bleeding The 691 System must only be installed by someone with good working knowledge of automotive brake and electri - cal systems. It is important that the installer of the 691 System under - stands fluid types used in various 691 Systems.
4 Typical Split System (1 1/2 x 1/2) Two independent braking systems. One system leads to the front and the rear brakes and the other system leads only to the rear brakes. Identifying Feature: 1. Two lines from master cylinder. 2. Single hose to each front wheel.
5 Power Unit Remote Reservoir - (optional) See 691 Accessories on page 19 DIMENSIONAL DATA 1 1/4" Diameter Bore Dual Actuator 1 1/4" Diameter Bore Single Actuator 1 3/4" Diameter Bore D.
CAUTION Label Pressure Switches 6 Several self adhesive labels are supplied with each 691 Brake Lock. Determine which labels are used in your application and affix in the vehicle cab in view of the operator. See page 1. Actuator 1. Repeat the mounting procedures for each actuator used in your system.
7 Determine the type of brake system on your vehicle, refer to page s3&4 .A l l brake systems in use today require the MICO 691 Actuator(s) be installed after the anti-lock brake valve and combination warning valve if so equipped. Contact MICO, Incorporated if you have questions.
8 vibration. Common methods used to absorb this shock are coiling the brake tubing or using a short length of purchased brake hose. Follow procedures outlined by the vehicle manufacturer or SAE specifications. 3. Connect the upstream line coming from the master cylinder to the fluid inlet port on one end of the actua- tor.
9 691 Wiring Instructions (Refer to diagrams on pages 14 & 15) The 691 System is designed for use on vehicles with a 12 volt DC, negative ground system. References to "ground" in this literature refer to vehicle chassis ground which is connected to the negative (-) battery terminal.
10 All electrical connections must be completed and the power unit reservoir filled with proper fluid before bleeding. The hydraulic brake system must be bled whenever any line has been disconnected.
11 6. Pressure Bleed - There are two options for pressure bleeding the brake system, either using a commercial pressurized bladder type bleeder or by activating the 691 Power Unit. Using commercial bleeder Follow manufacturer's instructions. Using 691 Power Unit A.
12 To Deactivate Lock Device 1. Disengage other provided holding devices. 2. Switch the user interface to "release" position. The "locked" indicator lamp will deactivate and the power unit will return brake system to static system pressure.
13 NOTES.
691 System Installation Checklist NOTE: As you install the 691 System complete this check list. Upon completion of the 691 installation, retain this checklist with the 691 Operation and Installation Manual.
o Yes o No 1. Are the wires protected from being hit or kicked and not hanging loose or pulled too tight? o Yes o No o N/A 2. If additional wire was added, is it the correct gauge and color as indicated in the 691 Operation and Installation Manual? o Yes o No 3.
14 BRAKE LOCK APPLICATIONS Horn Relay User Interface Schematic.
15 INTERLOCK APPLICATIONS Horn Relay User Interface Schematic.
16 TROUBLESHOOTING Before Troubleshooting Unplug wire harness connectors. Check to be sure contacts are clean and making good contact and re - connect. Check the integrity of all wiring at the connectors. Also check to be sure all unused wires are properly capped.
17 Situation Cause/Solution (Test in order indicated) When the 691 System is activated, the brakes will not lock-up and the power unit does not run. 1. No electric power. Check the battery, fuse, and wiring connections. 2. High Pressure Switch is inoperative.
18 NOTES The 691 System and "Motor Up" LED come on unexpectedly without being activated. 1. The control module is receiving false signals. Be sure stray signals are not being introduced into the external inputs. If the gray wire is not connected to an external input, ensure that it is capped off and not shorting to ground inadvertently.
19 691 MODELS AND REPLACEMENT PARTS Part Description Number 02-600-038 Remote Reservoir Kit for Silicone Fluid Models 02-600-049 Integral Reservoir Kit for All Type Fluid Models 32-820-022 11' Ex.
20 User Interface Control Module Actuator Actuator Repair Kit Main Harness Reservoir Breather Plug 32-585-007 32-585-006 20-460-013 02-600-035 32-820-021 34-001-089 32-585-007 32-585-006 20-460-014 02.
Ein wichtiger Punkt beim Kauf des Geräts Micon 691 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Micon 691 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Micon 691 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Micon 691 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Micon 691 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Micon 691 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Micon 691 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Micon 691. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Micon 691 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.