34003641FR/ AA - Page 1 T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R www.mgeups.com Installation and user manual Pulsar M 2200 RT 2U 2200 RT 3U 3000 RT 2U 3000 RT 3U 3000 RT 3U XL EXB.
34007776EN /AB - Page 2.
34007776E N/AB - Page 3 Introduction Environmental protection MGE UPS SYSTEMS has implemented an environmental-protection policy. Products are developed accordi ng to an eco-design approach. Subst ances This product does not contain CFCs, HCFCs or asbestos.
34007776EN /AB - Page 4 Introduction Pictograms Important instructions that must always be followed. Information, advice, help. Visual indication. Action.
34007776E N/AB - Page 5 Contents 1. Present ation 1.1 St andard positions ..... .............. .............. ................ .............. .............. ............... .............. ............ 6 T ower position ............ .............. ....
34007776EN /AB - Page 6 1. Presentation 1.1 Standard positions Tower position Rack position Dimensions (H x W x D) in mm Pulsar M 2200 RT 2U 440 x 86 x 640 Pulsar M 2200 RT 3U 440 x 131 x 490 Pulsar M.
34007776E N/AB - Page 7 1. Presentation 1.2 Rear panels Pulsar M 2200 / 3000 Pulsar M EXB (optional battery module) 1.3 Control panel (1) USB co mmunicat ion por t (2) RS232 communication port (3) Con.
34007776EN /AB - Page 8 2. Installation 2.1 Unpacking and contents check (30) Pulsar M 2200 or 3000 UPS (31) connection cable to AC-power source (32) 2 connection cables fo r the protected equipment (.
34007776E N/AB - Page 9 2. Installation 2.2 Installation in tower position 2.3 Installation in rack position It is advised to first install the battery module , then the power module above . Follow steps 1 to 4 for module mounting on the rails. The rails and necessary hardware are supplied by MGE UPS SYSTEMS.
34007776EN /AB - Page 10 2. Installation 2.4 Communication ports Connection of RS232 or USB communication port (optional) Installation of the communication cards (optional) The RS232 and USB commun ication ports cannot operate simultan eously.
34007776EN /AB - Page 11 2. Installation 2.5 Connections with a FlexPDU (Power Distribution Unit) module (optional) 2.6 Connections with a HotSwap MBP module (optional) The HotSwap MBP module makes it possible to serv ice or even replace the UPS wit hout affecting the connected loads ( HotSwap function).
34007776EN /AB - Page 12 2. Installation HotSwap MBP-module operation UPS st art-up with th e HotSwap MBP module 1 - Check that the UPS is correctly connected to the Hot Swap MBP module. 2 - Set switch (53) to the Normal po sition. 3 - Start the UPS by pressing the ON/OFF button (27) on the UPS control panel.
34007776EN /AB - Page 13 3. Operation 3.1 Start-up and norm al operation UPS personalisa tion 3.2 Operation on battery power T ransfer to battery power Low-battery warning For the initial start, AC power must be present to detect any wiring e rrors. Subsequently, the UPS can start even if AC power is not present.
34007776EN /AB - Page 14 3. Operation End of battery backup time 3.3 Return of AC power Following an outage, the UPS restarts auto matically when AC power retu rns (unless the restart f unction was disabled via UPS personalisation) and t he load is again supplied.
34007776EN /AB - Page 15 3. Operation Contact open: shut down of UPS Contact closed: start-up of UPS (UPS connected to the network and network energized) Note: local On/Off control via button (27) has priority over the remote control order.
34007776EN /AB - Page 16 4. Access to measurements and personalisation data 4.1 Display menus arrangement 4.2 Access to measurements Press the scroll button (25) to access any status conditions a nd alar ms, then the measurements for voltage, current, frequency, power output and battery backup time.
34007776EN /AB - Page 17 4. Access to measurements and personalisation data Output personalisation (1) These parameters may be modified only when the UPS is OFF. Detailed comments are available in the Persona l Solution-Pac software. ON/OFF personalisati on Battery personal isation 4.
34007776EN /AB - Page 18 5. Maintenance 5.1 Troubleshooting If LED (21) or (22) is ON, a fault or an alarm has occurred. Use the escape button (24) to stop the audio alarm.
34007776EN /AB - Page 19 5. Maintenance Troubleshooting a UPS equipped with the HotSwap MBP module 5.2 Battery-module replacement Safety recommendations The battery can cause electrocutio n and high short-circuit currents.
34007776EN /AB - Page 20 5. Maintenance Mounting the new battery module Carry out the above instruct ions in reverse order. 5.3 Maintenance on a UPS equippe d with the HotSwap MBP module D - Remove the metal protection cover in front of the battery (two screws).
34007776EN /AB - Page 21 5. Maintenance 5.4 Training centre To fully master operation of your MG E UPS SYSTEMS product and carry out level 1 servicing, see our complete range of technical training courses, avai lable in both French and English.
34007776EN /AB - Page 22 6. Appendices 6.1 Technical specifications (1) Depending on the output voltage selected: 200V / 2 08V / 220V / 230V / 240V, the output power is 1980VA / 1980VA / 2200VA / 2200VA / 2200VA.
34007776EN /AB - Page 23 6. Appendices 6.2 Glossary Bypass AC input Bypass line from the AC-power sour ce, controlled b y the UPS, used to directly supply the load if an overload or a malfunction occurs on the UPS. Backup time T ime during which t he load can be supplied by the UPS operating on battery power .
34007776EN /AB MGE UPS SYSTEMS T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R 140, Avenue Jean Kuntzmann ZIRST - M ontbonno t St Martin 38334 - Saint Ismier Cedex - Fr ance www.
Ein wichtiger Punkt beim Kauf des Geräts MGE UPS Systems 3000 RT 3U XL (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie MGE UPS Systems 3000 RT 3U XL noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für MGE UPS Systems 3000 RT 3U XL - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von MGE UPS Systems 3000 RT 3U XL reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über MGE UPS Systems 3000 RT 3U XL erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon MGE UPS Systems 3000 RT 3U XL besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von MGE UPS Systems 3000 RT 3U XL verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit MGE UPS Systems 3000 RT 3U XL. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei MGE UPS Systems 3000 RT 3U XL gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.