Meade Instruments Corporation INSTRUCTION MANUAL 16" Starfinder Reflecting Telescope.
W ARNING! Never use the Meade 16" Starfinder Telescope to look at the Sun! Observing the Sun, even for the shortest fraction of a second, will cause instant and irreversible damage to your eye as well as physical damage to the telescope itself.
- 3 - Captions for Fig. 1 1. Viewfinder 2. Spider vane/diagonal 3. Focuser 4. Main optical tube 5. P olar axis 6. Declination housing 7. Declination lock knob 8. Declination setting circ le 9. Counterweights 10. Declination shaft 11. Counterweight safety washer 12.
- 4 - 16" STARFINDER REFLECTING TELESCOPE: INTRODUCTION The 16" Starfinder Equatorial telescope will open up the skies for a breathtaking array of visual observations.
-5- Fig. 1; this should prevent rotation of the telescope about the declination axis. BALANCING THE TELESCOPE The telescope must be balanced around both axes in order for the mount to track accurately, keeping an object within the telescope's field of view.
-6- 12vDC Outlet The 12vDC Outlet accepts a #607 Power Cord (See OPTIONAL ACCESSORIES , page 12) for powering the 16" Starfinder Equatorial T elescope from a 12vDC automobile cigarette lighter plug. While the recommended supply voltage is 12vDC, the telescope will operate in a range of 6-18vDC.
-7- 4. Primary Mirror Adjustments If the secondary mirror and the reflection of the primary mirror (1), Fig. 8, appear centered within the drawtube (2), Fig. 8, but the reflection of your eye (3), Fig. 8, appears off-center, one or more of the three primary mirror hex screws of the primary mirror cell will need to be adjusted.
- 8 - Most observers will want to have 3 or 4 eyepieces and perhaps the #140 2x Barlow Lens to achieve the full range of reasonable magnifications. See OPTIONAL ACCESSORIES , page 11, for further details. ASTRONOMICAL OBSERVING The Starfinder telescope is an excellent observing tool for the ser io us am at eur a st rono mer.
-9- circles with the Celestial Pole at the center. By lining up the telescope's polar axis with the North Celestial Pole (or South Celes tial Pole if obs erving from the Ear th's Sou thern Hemisphere), celestial objects may be followed (tracked) by moving the telescope about one axis, the polar axis.
- 10 - 6. Remove the jumper from one prong and slide it onto both prongs. The telescope will now track in an easterly direction for southern hemisphere operations. 7. T o return the telescope to northern hemisphere operations, pull the jumper off both prongs and store it on one of the prongs.
4 . Use "fas t" f ilms (high A S A r atings) to re duce exp osure t i m e s . 5. Focus the image with extreme care. While observing the celestial object through the camera's viewfinder, turn the telescope's focus knob to achieve the sharpest possible focus.
- 12 - Eyepiece 16" f/4.5 Power SP 6.4mm 286X* SP 9.7mm 187X SP 12.4mm 148X SP 15mm 122X SP 20mm 92X SP 26mm 70X SP 32mm 57X SW A 13.8mm 133X SW A 18mm 102X SW A 24.5mm 75X SW A 32mm 57X UWA 4.7mm 389X* UW A 6.7mm 273X* UWA 8.8mm 208X UWA 14mm 131X * Should be used only under extremely steady atmospheric conditions.
- 13 - and point the telescope at a moderately bright (second or third magnitude) star, then center the star image in the telescope’s field-of-view. With the star centered, follow the method below: 1. Bring the star image slowly out of focus until one or more rings are visible around the central disc.
- 14 - plug (10), Fig. 18, to the circuit board (as described above in Step 4c). Replace the dust cover . Meade Customer Service If you have a question concerning your Meade Starfinder telescope, call Meade Instruments/Customer Service Dept. at 949-451-1450, or fax at 949-451-1460.
- 15 - FCC NOTICE This equipment has been tested and found to comply with the limits for a CLASS A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
M ea de In st ru me n ts Co rp or ati on World’s leading manufacturer of astronomical telescopes for the serious amateur . 6001 Oak Canyon, Irvine, California 92620 (949) 451-1450 Fax: (949) 451-1460 www.
Ein wichtiger Punkt beim Kauf des Geräts Meade 50 AZ-T (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Meade 50 AZ-T noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Meade 50 AZ-T - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Meade 50 AZ-T reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Meade 50 AZ-T erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Meade 50 AZ-T besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Meade 50 AZ-T verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Meade 50 AZ-T. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Meade 50 AZ-T gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.