Benutzeranleitung / Produktwartung TP-EGT-1 des Produzenten Maretron
Zur Seite of 18
® ® Revision 1.0 Page i TMP100 Temperature Module User’s Manual Revision 1.0 Copyright © 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N.
TMP100 User's Manual Page ii Revision 1.0 Revision History Revision Description 1.0 Original document.
® ® Revision 1.0 Page iii Table of Contents 1 Introduc tion .................................................................................................................. ......... 1 1.1 Firmware Revi sion ...........................
TMP100 User's Manual Page iv Revision 1.0 Table of Appendices Appendix A – NMEA 2000 ® Interfacing ............................................
® ® Revision 1.0 Page 1 1 Introduction Congratulations on your purchase of the Ma retron Temperature Modul e. Maretron has designed and built your TMP 100 to the highest standards for years of dependable and accurate service.
TMP100 User's Manual Page 2 Revision 1.0 - Ambient Air Temperature Probe (-20° C to 80°C or -4°F to 176°F) - Ring Terminal Probe (-20°C to 80°C or -4°F to 176°F) - Immersion Probe for Tanks or Plenums (-20°C to 80°C or -4°F to 176°F) - Exhuast Gas Temperature Probe (0°C to 900°C or 32° to 1652°F) 1.
® ® Revision 1.0 Page 3 2.3 Mounting the TMP100 Attach the TMP100 securely to the vessel usi ng the included stainle ss steel mounting screws or other fasteners as shown in Figure 1 below .
TMP100 User's Manual Figure 2 – NMEA 2000 ® Connector Face Views 2.4.2 Temperature Probe Connections The TMP100 temperature probe connections are made by connecting to the 12-pin terminal strip on the top of the unit. First, remove the f our screws at the corners of the unit detaching the splash guard from the unit.
® ® 2.4.2.1 Exhaust Gas Temperature (EGT) Probe The TP-EGT-1 exhaust gas temper ature probe may be used to measure temperatures other than exhaust gas temperatures; however, the TP -EGT-1 exhaust gas temperature probe is the only TMP100 temperature probe that has su fficient range to measure exhaust gas temperature.
TMP100 User's Manual Please refer to Figure 4 for connecting the TMP100 to a TR3K ring/under bolt thermistor temperature probe, TP-AAP-1 ambient air te mperature probe, or TP-IP-1 immersion temperature probe.
® ® Revision 1.0 Page 7 Temperature, Inside Tem perature, Engine Room Te mperature, Main Cabi n Temperature, Live Well Temperature, Bait Well Te mperature, Refrigeration Te mperature, Heating System Temperature, Freezer Temper ature, Exhaust Gas Temper ature, and User Defined Temperature #129-#144.
TMP100 User's Manual Page 8 Revision 1.0 2.5.5.3 Installation Description… The TMP100, along with all other Level A certified NMEA 2000 devices, has two user- programmable installation description fields.
® ® Revision 1.0 Page 9 5 Technical Specifications As Maretron is constantly impr oving its products, all specificat ions are subject to change without notice.
TMP100 User's Manual Page 10 Revision 1.0 128723 Temperature, High Range (Exhaust Gas Temperatur e) 0.5 times/second Electrical Parameter Value Comment Operating Voltage 9 to 32 Volts DC Voltage Power Consumption 50 mA NMEA 2000 ® Interface Load Equivalence Number (LEN) 1 NMEA 2000 ® Spec.
® ® 7 Installation Template Please check the dimensions before using the fo llowing diagram as a template for drilling the mounting holes because the printing proc ess may have distorted the dimensions. Figure 5 – Mounting Surface Template Revision 1.
TMP100 User's Manual Page 12 Revision 1.0 8 Maretron (2 Year) Limited Warranty Maretron warrants the TMP100 to be free from defects in materials and workm anship for t wo (2) years from the date of original purchase.
® ® Revision 1.0 Appendix A – NMEA 2000 Interfacing Page A1 Appendix A – NMEA 2000 ® Interfacing TMP100 NMEA 2000 ® Periodic Data Transmitted PGNs PGN 130310 – Environmental Parameters ( not.
TMP100 User's Manual Page A2 Appendix A – NMEA 2000 Interfacing Revision 1.0 PGN 130312 –Temperature The TMP100 uses this PGN to provide a regul ar transmission of various temperatures. The factory default for periodic transmission rate is once every two seconds.
Ein wichtiger Punkt beim Kauf des Geräts Maretron TP-EGT-1 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Maretron TP-EGT-1 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Maretron TP-EGT-1 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Maretron TP-EGT-1 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Maretron TP-EGT-1 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Maretron TP-EGT-1 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Maretron TP-EGT-1 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Maretron TP-EGT-1. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Maretron TP-EGT-1 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.