Revision 1.0 Page i ® ® DCM100 DC Monitor User’s Manual Revision 1.0 Copyright © 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23 rd Ave #10 Phoenix, AZ 85021-7850 http://www.
DCM100 User’s Manual Page ii Revision 1.0 Revision History Revision Description 1.0 Original document.
Revision 1.0 Page iii ® ® Table of Contents 1 Introduc tion .................................................................................................................. ......... 1 1.1 Firmware Revi sion ...........................
DCM100 User’s Manual Page iv Revision 1.0 4.3 Battery C apacity ..................................................................................................... 10 4.4 Battery Ty pes .................................................
Revision 1.0 Page 1 ® ® 1 Introduction Congratulations on your purchase of the Ma retron DC Monitor (DCM100). Maretron has designed and built your DC monitor to the highest st andards for years of dependable and accurate service.
DCM100 User’s Manual Page 2 Revision 1.0 2 Installation 2.1 Unpacking the Box When unpacking the box contai ning the Maretron DCM100, y ou should find the followin g items: 1 – DCM100 – DC Monitor 1 – DC Current Sensor with 5 ft. long cable (Part # LEMHTA200-S) (outer cable covering grey) 1 – Battery Temperature Sensor with 5 ft.
Revision 1.0 Page 3 ® ® 2.3 Mounting the DCM100 Attach the DCM100 securely to the vessel using the included stainless steel mounting screws or other fasteners as shown in Figure 1 below . Figure 1 – Mounting the DCM100 2.4 Connecting the DCM100 The DCM100 requires two electrical connec tions as shown in .
DCM100 User’s Manual Figure 2 – NMEA 2000 ® Connector Face Views 2.4.2 Connecting the DC power and Sensor Connections The DCM100’s DC Power and sens or connections are made by connecting to the 12-pin terminal strip on the top of the uni t. First, remove the four screw s at the corners of the unit securing the splash guard to the unit.
Revision 1.0 Page 5 ® ® e. Disconnect the wire from the positive termina l of the battery or other DC source that is being monitored and place it through the hol e in the Current Sens or such that the arrow on the Current Sensor points towards the battery or DC source.
DCM100 User’s Manual Page 6 Revision 1.0 Period, 17) Zero Current Threshold, 18) Manual ly Set Battery to 100%, 19) Current Sensor Zero Offset Calibration, and 20) NMEA 2000 PGN Enable/Disable. 2.5.1 Instance Selection NMEA 2000 ® provides a unique engine instance for ea ch DC power source on a vess el.
Revision 1.0 Page 7 ® ® 2.5.4.3 Equalization You may indicate here whether or not the battery supports equalization. This is used only for reporting over the NMEA 2000 network. Ava ilable choices are “Supported” and “Not Supported”. 2.5.4.4 Temperature Coefficient The capacity of a battery generally increases with increasing temperat ure.
DCM100 User’s Manual Page 8 Revision 1.0 available, you can set this par ameter to the estimated battery temperature, between -25°C and 125°C. 2.5.4.11 Time Remaining Floor The DCM100 calculates the time , given the current being dischar ged from the battery, before the battery becomes discharged.
Revision 1.0 Page 9 ® ® 3.1 Parameters Common to DC Sources and Batteries The parameters in this section are transmitt ed regardless of the “ DC Type” selected (see Section 2.5.3 for details). 3.1.1 Battery Voltage This parameter indicates the voltage pr esent across the battery terminals.
DCM100 User’s Manual Page 10 Revision 1.0 4 Background 4.1 Why Monitor Batteries? The lifetime and storage capacity of batteries can be greatly affected by the way in which they are used. Discharging a battery excessively or under-charging or over-charging a battery can ruin it.
Revision 1.0 Page 11 ® ® 4.5 Battery Safety Precautions 1. Lead-acid batteries generate explosive gases during operation. Make sure that the area around the batteries is well-ventilated. Ne ver allow flames or sparks near a battery. 2. Wear clothing and eye protec tion when working with batteries.
DCM100 User’s Manual Page 12 Revision 1.0 restated version of the equation, wh ich allows you to calculate t he time to totally discharge a given battery at a given discharge current, follows: ܶൌ.
Revision 1.0 Page 13 ® ® • Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove paint or markings or may corr ode the DCM100 enclosure or seals. • Ensure that the unit is mounted securely an d cannot be moved relative to the mounting surface.
DCM100 User’s Manual Page 14 Revision 1.0 automatically void the warranty. If service is required, please re turn the unit to an authorized Maretron service location. 8 Technical Specifications As Maretron is constantly impr oving its products, all specificat ions are subject to change without notice.
Revision 1.0 Page 15 ® ® Environmental Parameter Value IEC 60954 Classification Exposed Degree of Protection IP64 Operating Temperature -25°C to 55°C Storage Temperature -40°C to 70°C Relative Humidity 93%RH @40° per IEC60945-8.2 Vibration 2-13.
DCM100 User’s Manual 10 Installation Template Please check the dimensions before using the fo llowing diagram as a template for drilling the mounting holes because the printing proc ess may have distorted the dimensions. Figure 3 – Mounting Surface Template Page 16 Revision 1.
Revision 1.0 Page 17 ® ® 11 Maretron (2 Year) Limited Warranty Maretron warrants the DCM100 to be free from defects in material s and workmanship for t wo (2) years from the date of original purchase.
.
Revision 1.0 Appendix A – NMEA 2000 Interfacing Page A1 ® ® Appendix A – NMEA 2000 ® Interfacing DCM100 NMEA 2000 ® Periodic Data Transmitted PGNs PGN 127506 – DC Detailed Status The DCM100 uses this PGN to transmi t slowly changing DC and Battery Data Field 1: SID – The sequence identifier field is used to tie related PGNs together.
DCM100 User’s Manual Page A2 Appendix A – NMEA 2000 Interfacing Revision 1.0 PGN 127508 – Battery C onfiguration Status The DCM100 uses this PGN to transmi t unchanging battery configuration data. Field 1: Battery Instance – T his field indica tes the particular battery for which this data applies.
Ein wichtiger Punkt beim Kauf des Geräts Maretron DCM100 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Maretron DCM100 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Maretron DCM100 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Maretron DCM100 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Maretron DCM100 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Maretron DCM100 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Maretron DCM100 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Maretron DCM100. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Maretron DCM100 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.