17 Operating Manual Mark Levinson ® N º 29 Dual Monaural Power Amplifier Madrigal Audio Laboratories, Inc..
18 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
19 Important safety instructions Please read all instructions and precautions carefully and completely before operating your N º 29 Dual Monaural Power Amplifier. 1. ALWAYS disconnect your entire system from the AC mains before connecting or disconnecting any cables, or when cleaning any component.
20 Thank you for choosing the Mark Levinson ® N º 29 Dual Monaural Power Amplifier. A great deal of effort went into the design and construction of this precision device.
21 T able of c on t en ts Unpacking and placement ....................................................................... 1 Unpacking ................................................................................................. 1 Placement .......
1 Unpacking and placement Unpack your Nº29 amplifier and keep all packing materials for future transport. To avoid damaging the connectors on input cables attached to the rear panel, NEVER rest the Nº29 on the rear panel, and NEVER tip it back in a way that would put stress on these connectors.
2 V olt ag e se lec tion The Nº29 is factory-set (internally) for 100V, 120V, 200V, 220V, or 240V AC mains operation. Check that the label on the rear panel of the amplifier indicates the correct AC operating voltage for your location. Nº 29 DUAL MONAURAL AMPLIFIER + –– + SERIAL NO.
3 Signal connections The N º 29 incorporates RCA-type and XLR-type connectors for audio signal input. The Madrigal-designed RCA-type connectors used for single-ended audio interconnection are a great improvement over ordinary RCA- type connectors.
4 Inverting operation should be used if a phase reversal is required. In this mode of operation, the output signal of the amplifier will be 180 ° out of phase with the input signal. This may be required if one component in the system inverts the signal and absolute phase at the loudspeaker is desired.
5 If your preamplifier is equipped with a balanced main output, it's best to wire the N º 29 for balanced operation, particularly if long cable lengths are required between the preamplifier and the N º 29. (See Figure 3 for the pin assignments of the N º 29's XLR-type inputs.
6 Speaker connections NEVER connect the N º 29's output terminals to any device other than a loudspeaker. NEVER short-circuit the amplifier output terminals.
7 3. Strip 1/2" of insulation from the speaker cable. 4. Gently slide the (5/8") bare end of the 14-gauge wire into the center of the bare speaker cable (be careful not to spread the individual wires of the speaker cable). 1/2" (12.7mm) Speaker cable Solder Ti n Figure 7B: Pigtail connection 5.
8 Power connection After making your loudspeaker connections, apply power to your preamplifier and allow it to stabilize. (Mark Levinson preamplifiers, for example, require about one minute to stabilize.) Connect the AC power cord (included in the accessory pack) to the AC connector on the rear panel of the N º 29, then to the AC mains outlet.
9 Bridged operation When greater power output is desired, the N º 29 may be bridged for monophonic operation into load impedances of at least 2 Ω . Note: Make sure the loudspeaker is rated to handle high power levels. For example, a bridged N º 29 driving an 8 Ω loudspeaker is capable of delivering 200W RMS.
10 Figure 10: Balanced bridging cable 21 3 21 3 Signal ground (shield) Left-channel XLR male line-mount (rear view) Twisted pair Right-channel XLR male line-mount (rear view) 12 3 XLR female line-mount (rear view) Twisted pair Signal ground (shield) 2.
11 2. Connect the bridging cable between the left- and right-channel XLR-type input connectors, taking care to insert the correct cable end into its designated channel. You may fabricate such a cable according to Figure 12; it's also available through your Mark Levinson dealer as part of a single-ended bridging kit.
12 Car e an d m ain t e n an c e To remove dust from the cabinet of the N º 29, use a feather duster. To remove dirt and fingerprints, use isopropyl alcohol applied to a soft cloth. Poor connections cause sonic degradation. We recommend, therefore, that you clean all speaker connection with denatured alcohol at least once a year.
13 Specifications The correlation between published specifications and sonic quality is unreliable. A list of numbers reveals virtually nothing. All technical measurements must be subject to qualitative as well as quantitative interpretation. Measurements of the N º 29 yield excellent results by any standards.
14 Dimensions 17-1/2" (444.5) 1-3/4" (44.5) 1-3/32" (27.5) 3/8" (9.5) 4-1/8" (104.8) 14-3/16" (360.4) 29/32" (23.0) 1-9/16" (39.7) 4-29/64" (1 13.1) 1" TYP . (25.4) 1-7/16" TYP . (36.5) 1/8" (3.
16 630042-1 Printed in U.S.A. ©1993 Madrigal Audio Laboratories, Inc. All rights reserved. ® MADRIGAL AUDIO LABORATORIES 2081 South Main Street, P.O. Box 781 Middletown, Connecticut 06457 USA Telephone: (203) 346-0896 Fax: (203) 346-1540 is a registered trademark of Madrigal Audio Laboratories, Inc.
Ein wichtiger Punkt beim Kauf des Geräts Madrigal Imaging Dual Monaural Power Amplifier (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Madrigal Imaging Dual Monaural Power Amplifier noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Madrigal Imaging Dual Monaural Power Amplifier - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Madrigal Imaging Dual Monaural Power Amplifier reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Madrigal Imaging Dual Monaural Power Amplifier erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Madrigal Imaging Dual Monaural Power Amplifier besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Madrigal Imaging Dual Monaural Power Amplifier verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Madrigal Imaging Dual Monaural Power Amplifier. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Madrigal Imaging Dual Monaural Power Amplifier gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.