Benutzeranleitung / Produktwartung TM-4500 des Produzenten Lucent Technologies
Zur Seite of 20
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 1 45" Wood Burning Fireplaces P/N 850,045M REV. N/C 01/2007 TM-4500 MODEL RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WH Report No. J20054576-231 This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 TABLE OF CONTENTS Safety Rules .................................... page 2 Tools and Building Supplies ............ page 2 Precautions ..................................... page 3 Introduction .......
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Figure 1 TYPICAL INSTALLATION *Construction Materials: • framing materials • paneling • particle board • flooring • dry wall • etc. • plywood PRECAUTIONS Note: These fireplace systems are not difficult to install.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 Figure 2 LOCATION OF FIREPLACE Carefully select the proper location for heat circulation, aesthetics, chimney obstructions and clearance to side wall(s). With proper pre- planning, a slight adjustment of a few inches can save considerable time and expense later during construction and assembly.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 DO NOT permanently place furniture or other items such as decorative pillows within 60" of the fireplace front face. ASSEMBLY STEPS Note: The following steps represent the normal sequence of installation.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 Step 3. Refer to fireplace drawings and specifi- cations on pages 6 and 7 for framing dimensions and details.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 Note: The framed depth, 28 ¹ ⁵ ⁄ ₁ ₆ " (735 mm) from a framed wall, must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the framed depth must be measured from the drywall sur- face.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 Step 5. Fireplace should be secured to side framing members using the full length nailing tabs at the top and bottom of the fireplace front face.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 Step 4. Note: Chimney sections are constructed with a unique locking tab design, which en- sures an immediate, tight assembly between sections. Plan your chimney requirements care- fully before assembly as chimney is difficult to disassemble after installation.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 Locking Band Waterproof Caulk Roof Ridge 120 ° Step 8. The standard Security Chimneys FTF10 roof flashing assemblies include a storm collar. Slide the storm collar over outer chimney, rest on flashing spacers and align with top surface of flashing.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 11 MULTIPLE TERMINATIONS If more than one termination is located in the same chase or within the same general proxim- ity, we suggest they should be se.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 Figure 38 Figure 40 OFFSET CALCULATIONS Step 1. Use Offset Chart to determine amount of horizontal offset (A) and height (B) for various chimney section assemblies.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 397 ¹⁄₄ 33 1 ¹⁄₄ 20 1 1 403 ¹⁄₄ 33 7 ¹⁄₄ 11 1 1 411 34 3 0 0 12 421 ¹⁄₄ 35 1 ¹⁄₄ 10 1 2 427 ¹⁄₄ 35 7 ¹⁄₄ 01 .
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 Return Elbow Figure 41 Note: The return elbow assembly performs the same function as a stabilizer. Consider this when determining the need for a stabilizer. Note: Do not apply excessive pressure to any subsequent chimney section following return elbow assembly when installing.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 Outside combustion air ducting may be run upwards or vertically through framing and ceil- ing joists, with the hood installed through an outside wall and 3' (914 mm) below the termi- nation.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 16 Figure 46 Note: Only non-combustible wall finishing materials are allowed on the front top of the unit, from the top edge of spacers down. See Figures 45 and 46 . Hearth Extensions and Wall Shields A hearth extension must be installed with all fireplaces.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 Answer - The minimum required thickness of the Micore 160 is .417”, therefore round up to nearest standard thickness available which is 1/2”.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 Locking Band 63L60 FLB Figure 50 Figure 49 FINISH TO YOUR TASTE There are a wide variety of “finished looks” for these fireplaces, from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19 63L16 FTF10-12 63L17 FTF10-18 63L18 FTF10-36 62L94 FTF10-18C Chimney Section 62L95 FTF10-36C Storm Collar 63L59 FSC 63L40 F10F6 Flashing 63L41 F10F1.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 20 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
Ein wichtiger Punkt beim Kauf des Geräts Lucent Technologies TM-4500 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Lucent Technologies TM-4500 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Lucent Technologies TM-4500 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Lucent Technologies TM-4500 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Lucent Technologies TM-4500 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Lucent Technologies TM-4500 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Lucent Technologies TM-4500 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Lucent Technologies TM-4500. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Lucent Technologies TM-4500 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.