Gas-Fir ed V ented Room Heater INST ALLA TION AND OPERA TING INSTRUCTIONS P/N 80900 - REV . 12/03 This appliance is equipped with a safety control system designed to protect against improper venting of combustion products. THIS UNIT IS NOT TO BE INST ALLED IN MOBILE HOMES.
SPECIFICA TIONS………………………. 2 INTRODUCTION……………………….. 3 VENTING………………………………... 3 , 4 GAS SUPPL Y……………………………. 5 LOCA TION & SPECIAL PRECAUTIONS 5 COMBUSTION & VENTILA TION AIR.
INTRODUCTION THIS IS A GAS-FIRED, GRA VITY VENTED ROOM HEA TER THA T WILL OPERA TE SAFEL Y AND PROVIDE AN EFFICIENT SOURCE OF HEA T WHEN INST ALLED, OPERA TED AND MAINT AINED AS RECOMMENDED IN THESE INST ALLA TION AND OPERA TING INSTRUCTIONS. READ THESE INSTRCTIONS THOROUGHL Y BEFORE INST ALLING, SER VICING, OR USING THIS APPLIANCE.
VENTING 10’ or Less 2’ Min. 3’ Min. Ridge Chimney More than 10’ 10’ 2’ Min. 3’ Min. Ridge Chimney Height above any roof surface withon 10’ horizontally FIGURE A FIGURE A Seal around co.
GAS SUPPL Y This vented room heater must be connected to a gas supply capable of supplying the appliances full rated capacity . Provide a 1/8 inch N.P . T . plugged tapping, accessible for test gauge connection, immediately upstream of the gas supply connection to the appliance.
COMBUSTION AND VENTILA TION AIR When installed, this gas appliance must be provided with fresh air for combustion, ventilation, and dilution of hot flue gases. The minimum required volume of the area where the appliance is installed should be 50 cubic feet per 1,000 btu/hr .
CLEARANCES If the area where the appliance is to be installed contains carpeting, tile, or combustible materials, other than wood flooring, the appliance shall be installed on a metal plate (stoveboard), a wood panel, or other non-combustible materials.
PILOT ADJUSTMENT The pilot flame can be observed by opening the pilot lighting hole cover . The pilot flame should surround the top 3/8 to ½ inch of the thermocouple (see Figure 2). If the flame needs adjusting, first locate the pilot adjustment screw cap and remove.
CAUTION: There may be momentary and spasmodic orange flashes in the flame. This is caused by the burning of air borne dust particles and is not to be confused with the yellow tipping which is a stable or permanent situation when there is insufficient primary air .
10. Close pilot lighting hole cover and casing door . 11. Turn gas control knob counterclockwise to “ON”. 12. Turn temperature control knob to desired setting.
Flame too large 1. Defective operator section of gas valve. 1. Replace complete valve. 2. Burner orifice too large. 2. See orifice chart to determine the correct orifice size for your Model Number and elevation. 3. Pressure regulator malfunction. 3. Regulator must be adjusted by a qualified serviceman using proper tools and instruments.
Not enough heat 1. Heater undersized. 1. This is especially true when a dwelling or room is enlarged. Have the heat loss calculated and compare to the heater output (70% of input). Y our gas company or installer can supply you with this information. If heater is undersized, replace with correct size unit.
Page 13 CHB-3 BLOWER INST ALLA TION STEP 1. Run black wire and white wire that comes from bottom of junction box down through the heat shield. See Figure A. STEP 2. Insert junction box into opening in back of heater . Attach using four #8x1/2” black screws provided.
13 12 25 33 34 23 26 38 35 36 28 24 18 19 10 9 2 11 39 5 4 1 37 41 3 20 22 21 31 32 30 29b 29a 29c 29d 29e 28a 28b MODELS INCLUDED: VC / Closed Front Circulators VCR / Radiant Front Circulators CHB3 Blower VENTED CONSOLE HEA TER Prices and specifications subject to change without notice.
NA T . VC201A-R VC351,VCR351A-R VC501,VCR501A-R VC701, VCR701A-R MODEL NUMBER L.P . VC202A-R VC352,VCR352A-R VC502,VCR502A-R VC702, VCR702A-R REF . P A RT LIST P A RT LIST PA R T LIST P A RT LIST P ART DESCRIPTION NO. NO. PRICE NO. PRICE NO. PRICE NO.
IMPOR T ANT SAFETY BULLETIN ON YOUR GAS CONTROL AND PILOT LIGHT SYSTEM FOR HEA TING EQUIPMENT WHA T YOU DON’T KNOW CAN HUR T YOU. Y our pilot light system has been designed for safe and reliable operation. Although safety mechanisms are built-in, the potential for hazard exists.
The Louisville Tin & Stove Co. warrants to the original user the accompanying product for the period specified herein, provided said product is installed, operated, maintained, serviced, and used according to the instructions and specifications accompanying the product.
Ein wichtiger Punkt beim Kauf des Geräts Louisville Tin and Stove VC351A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Louisville Tin and Stove VC351A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Louisville Tin and Stove VC351A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Louisville Tin and Stove VC351A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Louisville Tin and Stove VC351A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Louisville Tin and Stove VC351A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Louisville Tin and Stove VC351A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Louisville Tin and Stove VC351A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Louisville Tin and Stove VC351A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.