Benutzeranleitung / Produktwartung SLM2008 des Produzenten Linksys
Zur Seite of 32
USER GUIDE BUSINESS SERIES 5-P or t and 8-P or t 10/100/1000 Gigabit Smar t S witch with PD and A C P o w er Model: SLM2005, SLM2008.
i About This Guide 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er About T his Guide Icon Descriptions While reading thr ough the User Guide y ou may encount er various icons designed to call attention to a specific item.
ii T able of Contents 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Chapter 1: Introduction 1 Chapter 2: Product O verview 2 F ront P anel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
iii T able of Contents 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Multicast > IGMP Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Admin > P ing . . . . . . . . . . . .
1 Introduc tion 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Chapter 1 Chapter 1: Intr oduc tion The 5-port and 8-por t 10/100/1000 Gigabit Smart Switches with PD and A C P ow er allow you t o upgrade your existing 10/100 network by r eplacing y our current workgr oup hub or switch.
2 Produc t Over view 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Chapter 2 Chapter 2: Pr oduct O verview Front P anel The LEDs are locat ed on the front panel of the Swit ch. Fr ont P anel - SLM2008 Sy stem (Green) Lights up green to indicate that power is being supplied to the S witch.
3 Installation 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Chapter 3 Chapter 3: Installation Over view This chapter will explain how to connect network devices to the Switch. The following diagram shows a t ypical network configuration.
4 Installation 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Chapter 3 Placement Options There are t wo ways to physically install the Switch, either hang the Switch on a wall using its wall-mount slots or place it on a desktop .
Chapter 4 Advanced Configura tion 5 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Chapter 4: A dvanc ed C onfigur a tion Open your web browser and enter http://192.168.1.254 into the addr ess field. P ress the Enter key and the Password screen will appear .
Chapter 4 Advanced Configura tion 6 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Be sure to click Save Settings and reboot the Switch by going to Admin > Reboot .
Chapter 4 Advanced Configura tion 7 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Port > LACP Settings Port Displays the port number . Enable LACP Enables LACP . Admin Ke y A channel will only be formed between ports having the same admin key.
Chapter 4 Advanced Configura tion 8 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Enable Tx Forc e Untag When this option is enabled, all egress frames from this port become untagged.
Chapter 4 Advanced Configura tion 9 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er RADIUS UDP Port Enter the UDP Port of the ser ver . The UDP por t is used to verify the RADIUS ser ver authentication. The default value is 1812 .
Chapter 4 Advanced Configura tion 10 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Management IP address 1 Enter the IP address of a device that you wish t o allow manage the Switch. Management IP address 2 Enter the IP address of a second device that y ou wish to allow manage the Swit ch.
Chapter 4 Advanced Configura tion 11 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er QoS Mode Set the Q oS Mode to Q oS Disabled, 802.1p, P ort Based, or DSCP . 802.1p Enabled? 802.1p QoS Y es Y es No No Port QoS No No DSCP QoS Y es Y es T agged? DSCP Found? Packet DSCP Enabled? QoS Mode Priority Diagram 802.
Chapter 4 Advanced Configura tion 12 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Sy stem Priority Bridge prior ity is used in selecting the root device , root port, and designated por t. The device with the highest prior ity becomes the ST A root device.
Chapter 4 Advanced Configura tion 13 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Rx Fr ames Displays the number of frames received on the port since the device was last refreshed. Tx Errors Displays the number of transmitted packets with err ors that have occurred on the port since the device was last refreshed .
Chapter 4 Advanced Configura tion 14 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Ping Paramet ers T arget IP A ddress Enter the IP Addr ess of the device y ou want to ping . Coun t Set the maximum count to the target IP Address for each attempt.
Chapter 4 Advanced Configura tion 15 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Admin > Firm w are Upgrade Allows you to upgrade the firmware using your Web browser . Admin > FIrmware Upgr ade Firm war e Upgrade T o do so, per form the following steps: Click the Brow se button.
16 Glossar y 5-Port and 8-Port 10/100/1000 Gigabit Smart Switch with PD and AC P ow er Appendix A Appendix A: Glossar y This glossar y contains some basic networking terms you may come across when using this pr oduct. WEB: F or additional terms, please visit the glossary at w w w .
17 Glossar y 5-Port and 8-Port 10/100/1000 Gigabit Smart Switch with PD and AC P ow er Appendix A CoS (Class of Ser vice) The 802.1p priority scheme. CoS provides a method for tagging packets with priorit y information.
18 Glossar y 5-Port and 8-Port 10/100/1000 Gigabit Smart Switch with PD and AC P ow er Appendix A MAC (Media Ac cess Control) Address The unique address that a manufac turer assigns to each net working device. Mask A filter that includes or excludes cer tain values, for example parts of an IP address.
19 Glossar y 5-Port and 8-Port 10/100/1000 Gigabit Smart Switch with PD and AC P ow er Appendix A T CP ( T ransmission Control Protoc ol) A network protocol for transmitting data that requires ack nowledgement from the recipient of da ta sent.
20 Specific ations 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix B Appendix B: Specifications SLM2005 Specifications Ports 5 RJ-45 Connectors for 10BASE-T/100BA.
21 Specific ations 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix B SLM2008 Specifications Ports 8 RJ-45 Connectors for 10BASE-T/100BASE-TX/ 1000BASE-T Auto MDI/.
22 Warranty and R egulatory Information 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix C Appendix C: W arranty and Regulat or y Informa tion Limited W arranty Lin.
23 Warranty and R egulatory Information 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix C FCC Sta tement This produc t has been tested and complies with the specifications for a Class B digital device, pursuant to Part 15 of the FC C Rules.
24 Warranty and R egulatory Information 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix C User Inf ormation f or Consumer Products Cov ered b y EU Directive 2002/9.
25 Warranty and R egulatory Information 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix C Eesti (Estonian) - Keskkonnaalane informatsioon Euroopa Liidus asuv atele.
26 Warranty and R egulatory Information 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix C Lietuvškai (Lithuanian) - Aplink osaugos inf ormacija, skir ta Europos S.
27 Warranty and R egulatory Information 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix C Português (P ortuguese) - Informação ambiental para clientes da União.
28 Contac t Informa tion 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix D Appendix D: C ontact Informa tion Linksys C ontact Information W ebsite http://www .linksys.com E-Mail suppor t@linksys.c om FTP Site ftp.linksys .
Ein wichtiger Punkt beim Kauf des Geräts Linksys SLM2008 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Linksys SLM2008 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Linksys SLM2008 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Linksys SLM2008 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Linksys SLM2008 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Linksys SLM2008 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Linksys SLM2008 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Linksys SLM2008. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Linksys SLM2008 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.