1600advsvc REV: 1/8/07 SER VICE MA NUAL (DOMESTIC ) IMPING ER CONVEYOR O VENS LOW PROFILE 1600 SERIES ADVANTAGE Lincoln Foo dservice Products, LLC 1111 North Hadley Road Fort W ayne, Indiana 46804 United States of America Phone : (800) 374 -3004 U.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 2 TABLE OF CONTENTS TABLE OF CO NTENT S................................. ......................................................................... ..............................
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 3 SEQUENCE OF OPERA TIONS / 1 600-000-A , 16 01-000-A MODEL 16 00-000-A / 12 0 VAC / 60 HZ / NATURAL G AS MODEL 16 01-000-A / 12 0 VAC / 60 HZ / L.P. GA S POW ER SUPPLY Electrical po wer to be sup plied to the o ven by a thre e conductor c ordset.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 4 TROUBLESHOOTING GUIDE GAS OVEN S MODEL 16 00-000-A / NAT URAL GAS / 1 20 VAC / 6 0 HZ / 1 PHA SE MODEL 16 01-000-A / L.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 5 Cooling Fan(s ) 120 VAC shou ld be at the motor . If voltage is present , check motor for shorts, opens, or grounds. W ITH POW ER OFF: check for locked rotor. Gas Suppl y Check for adequate gas su pply and clos ed manua l gas valves.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 6 are no obstruc tions, replac e gas contr ol valves. Hot Surf ace Igniter The ignition c ontrol will k eep the gas c ontrol val ves energized for 6 sec onds.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 7 Interm ittent Heating Therm al/Overload of Main Fan an d Burner Blower Motors The m ain fan motors and the burner bl ower motors are equipped with internal th erm al protection and will cease to operate if o verheating oc curs.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 8 Power Supp ly Check power supply at the DC control b oard for the 12 0 VAC at board term inals L1 and L2. Motor Contro l Board Place the test m eter probes on t erm inals A+ and A-.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 9 Display Tr ansformer Measure the trans former primar y for a nom inal 120 VAC in put, if voltage is n ot present, trace wiring b ack to the o ven power source. Me asure the seco ndary output, which will nor mall y be 12-15 VAC.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 10 SCHEMATIC / 1600 -000-A, 1601-000- A.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 11 REMOVAL, INST ALLA TION & ADJUSTMENTS MODEL S ERIES 1600 ADVANTAGE C A UTION ! BEFORE R EMOVING OR I NSTALLING ANY COMPO NENT IN T HE IMPINGER OVEN BE SU RE TO DISC ONNECT EL ECTRICAL P OWER AND G AS SUPPL Y BURNER CO NTROL - HONEYWELL - REPL ACEMENT A.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 12 D. Reassem ble in reverse or der and chec k s y stem oper ation. CONVEYOR CO NTROL BOARD - C ALIBRATION A.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 13 GAS V A LVE, DU AL S A FETY - REPL A CEM ENT A. Rem ove appropriate contr ol box cover. B. Rem ove incoming gas l ine. C. Rem ove screws from incom ing nipple mounting br acket.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 14 E. Rem ove assembl y and repl ace m ain orifice. F. Reassem ble in reverse or der and chec k s y stem oper ation. NOT E: Check all gas line f ittings for le aks. TEM PERA TURE CONTR OL POTENT IOMETER - REPL A CEMENT A.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 15 REL A Y - REPL ACEMENT A. Rem ove control box cover. B. Rem ove wires from relay, note wire num bers and loca tion for reinsta llation. C. Rem ove two (2) screws f rom relay base and replace r elay.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 16 COOLING FAN MOTO R - REPL A CEM ENT A. Rem ove appropriate contr ol box cover. B. Rem ove mounting scre ws. C. Unplug electr ical connector and rem ove fan motor as sembl y .
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 17 It is poss ible to check a thermoc ouple with a proper ly calibrate d D.C. m illivolt meter. At 32° F, the millivolt re ading shou ld be 0.00. This can be chec ked by inserti ng the therm ocouple into an ice bath.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 18 PARTS / GENER A L - 1600-0 00-A ADVANTAGE SERIES LETTER PART # DESCRIPT ION A 369110 Access W indow Assy B 369929 Window Re.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 19 BLOW UP / GENERAL – 1600-000-A ADVANT A GE SERIES.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 20 PARTS / CONTROL B OX, RIGHT - 1600 -000-A , 1601-0 00-A LETTER P ART # DESCRIPT ION A 369158 Sprock et, 10 Tooth B 369705 T hermocouple C 369757 Main O rifice, Nat. 370279 Main O rifice, L.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 21 BLOW UP / CONTROL BOX, RIGHT - 1600 -000-A , 1601-0 00-A.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 22 PARTS / CONTROL B OX, LEFT - 1600-00 0-A , 1601-0 00-A LETTER P ART # DESCRIPT ION A 369706 T hermocouple with Extension B .
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 23 BLOW UP / CONTROL BOX, LEFT - 1600-000- A , 1601-000 -A.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 24 PARTS / OVEN B A CK - 16 00-000-A - SERIES LETTER P ART # DESCRIPT ION A 369547 W ire Form Therm ostat Bulb B 369724 Fan, C lockwise Rotat ion C 369776 Fan S hroud D 369777 Stand-O ff E 369778 Rear W all Ass y.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 25 BLOW UP / OVEN BACK - 1600-000-A - SERIES.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 26 PARTS / CONVEYOR - 16 00-000-A - SERIES LETTER P ART # DESCRIPT ION 369830 Com plete Conve y or A 369816 Con veyor Belting .
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 27 BLOW UP / CONVEYOR - 1600-000- A – SERIES.
Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 28.
Ein wichtiger Punkt beim Kauf des Geräts Lincoln 1600 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Lincoln 1600 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Lincoln 1600 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Lincoln 1600 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Lincoln 1600 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Lincoln 1600 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Lincoln 1600 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Lincoln 1600. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Lincoln 1600 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.