LG Room Air Conditioner SERVICE MANUAL LG MODEL: WG1805RY6,RAD-183A WG2405RY6,RAD-243A CAUTION website http://www.lgservice.com • BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
2 Room Air Conditioner Air Conditioner Ser vice Manual T ABLE OF CONTENTS Safety Precautions ..........................................................................................................................................3 Dimensions .......
Ser vice Manual 3 Saf ety Precautions Safety Precautions T o pre v ent injur y to the user or other people and proper ty damage, the f ollowing instructions must be f ollowed. ■ Incorrect operation due to ignoring instruction will cause har m or damage.
4 Room Air Conditioner Saf ety Precautions Do not modify or extend the po wer cord. • There is risk or fire or electric shock. Do not install, remove, or re-install the unit b y y ourself. • There is risk of fire, electric shock, e xplosion, or injur y .
Dimensions Dimensions 675 (770) 660 428 W mm(inch) 660(26") 660(26") H mm(inch) 428(16 27 / 32 ") 428(16 27 / 32 ") D mm(inch) 675(2 6 9 / 18 ") 675(269/18") Model Dimension 18K Btu 24K Btu Outside Dimensions This symbol alerts you to the risk of electric shoc k.
6 Room Air Conditioner Specfications Pr oduct Specifications POWER SUPPLY COOLING CAPACITY INPUT RUNNING CURRENT REFRIGERANT (R-22) CHARGE(g) OPERATING INDOOR(°C) TEMPERATURE OUTDOOR(°C) EVAPORATOR CONDENSER FAN, INDOOR FAN, OUTDOOR FAN SPEEDS, FAN/COOLING FAN MOTOR OPERATION CONTROL ROOM TEMP.
7 Room Air Conditioner Specfications Pr oduct Specifications POWER SUPPLY COOLING CAPACITY INPUT RUNNING CURRENT REFRIGERANT (R-22) CHARGE(g) OPERATING INDOOR(°C) TEMPERATURE OUTDOOR(°C) EVAPORATOR CONDENSER FAN, INDOOR FAN, OUTDOOR FAN SPEEDS, FAN/COOLING FAN MOTOR OPERATION CONTROL ROOM TEMP.
7 Room Air Conditioner Specfications Pr oduct Specifications POWER SUPPLY COOLING CAPACITY INPUT RUNNING CURRENT REFRIGERANT (R-22) CHARGE(g) OPERATING INDOOR(°C) TEMPERATURE OUTDOOR(°C) EVAPORATOR CONDENSER FAN, INDOOR FAN, OUTDOOR FAN SPEEDS, FAN/COOLING FAN MOTOR OPERATION CONTROL ROOM TEMP.
Se r vice Ma n ual 8 Installation Installation Select the Best Location Installation Chec k How to Secure the Drain Pipe 1.To prevent vibration and noise, make sure the unit is installed securely and firmly. 2.Install the unit where the sunlight does not shine directly on the unit.
9 Room Air Conditioner Installation Window Requirements Installation Kits Contents All supporting parts should be secured to firm wood, masonry, or metal. 1. This unit is designed for installation in standard dou- ble hung windows with actual opening widths from 26" to 41".
Se r vice Ma n ual 10 Installation Suggested T ool Requirements PREP ARA TION OF CHASSIS 1. Remove the screws which fasten the cabinet at both sides and at the back. 2. Slide the unit out from the cabinet by gripping the base pan handle and pulling forward while bracing the cabinet.
11 Room Air Conditioner Installation Cabinet Installation 1. Open the window. Mark a line on the center of the window stool between the side window stop mold- ings. Loosely attach the sill bracket to the support bracket using the carriage bolt and the lock nut.
Se r vice Ma n ual 12 Installation 5. Pull each Frame curtain fully to each window sash track, and pull the bottom window sash down behind the Top retainer bar until it meets. 6. Attach each Frame curtain the window sash by using screws (Type C.) (See Fig.
13 Room Air Conditioner • Designed for COOLING ONLY. • Powerful and whispering cooling. • Slide-in and slide-out chassis for the simple instal- lation and service.
Se r vice Ma n ual 14 Operation 2. Cooling Only Model with Remote Contr ol and T ouch T ype POWER BUTTON Operation starts, when this button is pressed and stops when you press the button again. OPERATION MODE SELECTION BUTTON Select Cooling, or Fan or Dehumid mode with button.
15 Room Air Conditioner Disassembly Disassembl y Mechanical P arts — Before the following disassembly, CONTROL BOX set to OFF and disconnect the power cord. 1. Front Grille 1. Open the lnlet grille upward . 2. Remove the screw that fastens the front grille.
Se r vice Ma n ual 16 Disassembly Air Handling P ar ts 4. Cover (at the top) 1. Remove the front grille. (Refer to section 17) 2. Remove the cabinet. (Refer to section 18) 3. Remove 11 screws which fasten the brace and covers. 4. Remove the covers and the brace.
17 Room Air Conditioner 6. Shroud 1. Remove the fan. (Refer to section 21) 2. Remove the screw that fastens the shroud. 3. Remove the shroud. (See Figure 24) 4. Re-install the component by referring to the removal procedure, above. 7. Motor 1. Remove the cabinet.
Se r vice Ma n ual 18 Disassembly 9. Capacitor 1. Remove the control box. (Refer to section 19) 2. Remove the knobs and the screw that fasten control panel from control box. 3. Remove the screw that located in the front. 4. Open the bottom side of control box.
19 Room Air Conditioner Disassembly CA UTION: Dischar g e the refrigerant system using a Freon TM Recovery System. If there is no valve to attac h the recovery system, install one (such as a W A TCO A-1) before venting the Freon TM . Leave the v alve in place after servicing the system.
Se r vice Ma n ual 20 Disassembly — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to Discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM .
21 Room Air Conditioner Disassembly Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a leak-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve.
Se r vice Ma n ual 22 Schematic Diagram Schematic Dia gram Electr onic Control De vice WP Vcc Digit3 (Scan3) Digit4 (Scan4) Digit1 (Scan1) Digit2 (Scan2) Digit0 (Scan0) MAIN POWER COMP HERM FAN C CAPACITOR MOTOR FAN 120 1/2W ZNR01J TVR14271 250V/T3.
23 Room Air Conditioner Schematic Diagram Wiring Diagram WH(BL) POWER INPUT BK(BR) (Ribbed) (Plain) GN/YL (GN) GN/YL(GN) THERMIST OR BK BK BL RD BL RD CN-TH1 YL YL OR(BR) OR(BR) OR(BR) SYNC M OTOR R Y -LO R Y -HI CN-WORK CN-SYNC CN-DISP DISPLA Y P .W .
Se r vice Ma n ual 24 Schematic Diagram Components Location Main P .W .B Assembly Display P .W .B Assembl y.
25 Room Air Conditioner T roubleshooting Guide T r oubleshooting Guide Piping System Figure 34 is a brief description of the important components and their function in what is called the refrigeration system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle.
Se r vice Ma n ual 26 T roubleshooting Guide T r oubleshooting Guide In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.
27 Room Air Conditioner T roubleshooting Guide Fails to Start Check circuit breaker and fuse. Gas leakage of feeler bulb of thermostat Check of control switch. Fan only fails to start. Improper wiring. Defect of fan motor capacitor . Irregular motor resistance ( ).
Se r vice Ma n ual 28 T roubleshooting Guide Electrical P ar ts T roub leshooting Guide Possible Trouble 1 The unit does not operate. Is the Trans output power AC 220V? Is the Trans output power about AC 14V? Is shorted the Trans. output? Is output Voltage of IC01D DC 12V? Is output Voltage of IC02D DC 5V? Is the voltage No.
29 Room Air Conditioner T roubleshooting Guide Is setting Temp. set lower than Room Temp.-0.5 ° C? Is the voltage No.10 of IC01M 0V? • Exchange IC01M. • Select the setting Temp. to lower Number. • Wait 3 Minutes. Is the Unit for 3 minutes delay? • Exchange MAIN PCB Ass'y.
Se r vice Ma n ual 30 T roubleshooting Guide • Exchange IC01M. • Exchange IC01M. Is the voltage NO.1 or 4 of IC01M DC 5V? Is the voltage NO.13 or 16 of IC01M 0V? • Check the RY-Hi or RY-Lo. • Check the wiring diagram. NO NO YES YES • Exchange Micom.
31 Room Air Conditioner T roubleshooting Guide NO NO NO NO YES YES YES Is the IC01G all right? Is the connection of CN-DISP all right? • Exchange the display PCB Ass'y. • Exchange IC01G. • Exchange Q01G-Q04G. • Connect connector to CN-DISP exactly.
Se r vice Ma n ual 32 T roubleshooting Guide COMPLAINT CAUSE REMEDY Check voltage at outlet. Correct if necessary. Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open. Check switch continuity. Refer to wiring diagram for terminal identification.
33 Room Air Conditioner T roubleshooting Guide COMPLAINT CAUSE REMEDY Check the position of knob If not at the coldest set- ting, advance the knob to this setting and restart unit. Check continuity of the thermostat. Replace ther- mostat if circuit is open.
Se r vice Ma n ual 34 T roubleshooting Guide COMPLAINT CAUSE REMEDY Test capacitor. Check the terminals. If loose, repair or replace. Check the system for a restriction. If restricted, clean of replace. Close if open. Determine if the unit is properly sized for the area to be cooled.
Room Air Conditioner Exploded View Exploded Vie w 554030 159830 135314 147581-1 147581-2 135312 552111 554031 148000 352380 349600 346811 130410 354210 147582 349001 359012 349480 W48602 W48602 559011.
Room Air Conditioner Exploded View Exploded Vie w 554030 159830 135314 147581-1 147581-2 135312 552111 554031 148000 352380 349600 346811 130410 354210 147582 349001 359012 349480 W48602 W48602 559011.
36 Room Air Conditioner Replacement P ar ts List R: Service Parts NOTE) * Please ensure GCSC since these parts may be changed depending upon the buyer's request.
PART NO WG2405RY7 130410 BASE ASSEMBLY,SINGLE 3041A30001F R 130910 CABINET ASSEMBLY,SINGLE 3091AR6056P R 135312 GRILLE ASSEMBLY,FRONT(SINGLE) 3531A11002B R 135303 GRILLE,INLET 3530A10189A R 135515 COVER ASSEMBLY, CONTROLINDOOR) 3551A30001A R 146812 MOTOR ASSEMBLY,SYNC.
PART NO RAD-183A 130410 BASE ASSEMBLY,SINGLE 3041A30001H R 130910 CABINET ASSY,SINGLE 3091AR6056P R 135312 GRILLE ASSY,FRONT(SINGLE) AEB30969401 R 135303 GRILLE ASSY,INLET 3530AR1604A R 1355 0 0 COV.
PART NO(2006) RAD-243A 130410 BASE ASSEMBLY,SINGLE 3041A30001F R 130910 CABINET ASSY,SINGLE 3091AR6056P R 135312 Grille ASSY,Front(SINGLE) AEB30969401 R 135314 Grille ASSY,Inlet 3530AR1604A R 135510 C.
P/No.: 3828A20887A JULY, 2007 Printed in China.
Ein wichtiger Punkt beim Kauf des Geräts LG Electronics WG2405RY6 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie LG Electronics WG2405RY6 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für LG Electronics WG2405RY6 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von LG Electronics WG2405RY6 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über LG Electronics WG2405RY6 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon LG Electronics WG2405RY6 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von LG Electronics WG2405RY6 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit LG Electronics WG2405RY6. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei LG Electronics WG2405RY6 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.