Room Air Conditioner SER VICE MANU AL MODEL: L WJ0561A CG L WJ0561 A CP /AAG CA UTION - BEFORE SER VICING THE UNIT , READ THE "SAFETY PRECA UTIONS" IN THIS MANU AL. - ONL Y FOR A UTHORIZED SER VICE PERSONNEL. WEBSITE http://biz.LGservice.com E-MAIL http://www .
—2— CONTENTS 1. PREF A CE .................................................................................................................................................. 3 1.1 FEA TURES ..........................................................
—3— 1. PREF A CE This ser vice man ual provides v arious ser vice inf or mation, including the mechanical and electrical par ts , etc. This room air conditioner was man ufactured and assemb led under a strict quality control system. The refrigerant is charged at the f actor y .
—4— 1.3 LOCA TIONS OF CONTROLS 1.4 SAFETY PRECA UTIONS 1. When ser vicing, set the RO T AR Y SWITCH to Off ( 0 ) and unplug the power cord. 2. Obser ve the original lead dress. If a shor t circuit is f ound, replace all par ts which hav e been ov erheated or damaged by the short cir- cuit.
— 5 — 2. DISASSEMBL Y INSTR UCTIONS 2.1 MECHANICAL P ARTS 2.1.1 FRONT GRILLE 1. Disconnect the unit from the power source . 2. Remov e the two knobs b y pulling them off. Using a screwdriv er , remov e the screw that secures the front grille to control board.
— 6 — 2.2 AIR HANDLING P ARTS 2.2.1 AIR GUIDE UPPER 1. Disconnect the unit from the power source . 2. Remov e the front grille. (Ref er to Section 2.1.1) 3. Remov e the cabinet. (Ref er to Section 2.1.2) 4. Remov e the control board. (Ref er to Section 2.
— 7 — 2.2.3 MO T OR 1. Disconnect the unit from the pow er source. 2. Remov e the front grille. (Ref er to Section 2.1.1) 3. Remov e the cabinet. (Ref er to Section 2.1.2) 4. Remov e the control board. (Ref er to Section 2.1.3) 5. Remov e the air guide upper .
— 8 — 2.3.3 CAP A CITOR 1. Remov e the cabinet. (Ref er to Section 2.1.2) 2. Remov e the control board. (Ref er to Section 2.1.3) 3. Discharge the capacitor by placing a 20 K Ω resistor across the capacitor ter minals. 4. Remov e the screw which f astens the capacitor clamp .
2.4.2 EV APORA T OR 1. Remov e the cabinet. (Ref er to section 2.1.2) 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Remov e the air guide upper . (Ref er to Section 2.2.1) 4. After discharging the refrigerant completely , unbraze the interconnecting tube at the e vaporator connections.
— 10 — Equipment needed: V acuum pump , charging cylinder , manifold gauge , brazing equipment, pinch-off tool capab le of making a vapor proof seal, leak detector , tubing cutter , hand tools to remove components and service valv e.
— 11 — 3. INST ALLA TION This air conditioner is designed with a button- down chassis so that it can be installed simply in a window . 3-1. SELECT THE BEST LOCA TION 1. T o pre vent vibr ation and noise, mak e sure the unit is installed securely and firmly .
— 12 — 3.4 HO W T O INST ALL • WHEN USING GASKET 2 1 2 F E C 3 G A B RIGHT SIDE HORIZONTAL LINE D 1. WINDO W (A - WIDTH ,B-H EIGHT) 2. GASKET 3. W ALL AB C D E F G 487mm 324mm 30mm 0~25mm O VER .
— 13 — 4.2 PIPING SYSTEM F ollowing is a brief descr iption of the impor tant components and their function in what is called the refr igeration system. Ref erence should be made to Figure 26 to follo w the refrigerating cycle and the flow of the refrigerant in the cooling cycle.
— 14 — 4.3 TR OUBLESHOO TING GUIDE In general, possib le trouble is classified in two kinds . The one is called Starting Failure which is caused from an electrical defect. The other is Ineff ective Air Conditioning caused from a def ect in the refrigeration circuit and improper application.
— 15 — Fails to Start Improper thermostat setting Loose terminal connection Improper wiring Check of po wer source. Drop of power v oltage. Capacitor check. Replacement. Check of control s witch setting. Compressor f ails only to star t. Def ect of compressor capacitor .
— 16 — ROOM AIR CONDITIONER V OL T A GE LIMITS NAME PLA TE RA TING MINIMUM MAXIMUM 220V~240V 198V 264V COMPLAINT CA USE REMED Y F an motor will not run. No power Check v oltage at outlet. Correct if none. P ow er supply cord Check v oltage to rotar y s witch.
— 17 — COMPLAINT CA USE REMED Y F an motor noise. F an If crac ked, out of balance, or partially missing, replace it. Blower If crac ked, out of balance, or partially missing, replace it. Loose set screw Tighten it. W or n bear ings If knocking sounds contin ue when running or loose, replace the motor .
— 18 — COMPLAINT CA USE REMED Y Compressor cycles on F an motor If not r unning, deter mine the cause. Replace if ov erload required. Condenser air flow Remov e the cabinet, inspect the interior surface restriction of the condenser . If restricted, clean carefully with a vacuum cleaner (do not damage fins) or brush.
5. SCHEMA TIC DIA GRAM — 19 — 5-1. CIRCUIT DIA GRAM • MODEL : L WJ0561A CG MOTOR C F H 7 8 6 4 2 1 5 3 H L M POWER INPUT ROTARY SWITCH THERMOSTAT BR BK RD BK RD OR(BR) YL BK(BR) (Plain) WH(BL) (Ribbed) GN(GN/YL) COMP.
— 20 — • MODEL : L WJ0561A CP/AA G DESCRIPTION & NAME P O W E RC O R DA S S Y FA N M O T O R COMPRESSOR ROT ARY SWI T C H THERMOST A T CAP A CIT OR O VERLO AD PRO TECT OR Q'TY 1 1 1 1 1 1 1 REF .
— 21 — 6. EXPLODED VIEW 152302 135313 352390 159900-2 145200 159900-1 130410 359012 W48602 135312 149410 354210 349480 352380 149980 559011 346811 554030 266003 264110 269310 W0CZZ 249950 135510 5.
— 22 — 7. SER VICE P AR TS LIST 130410 BASE ASSEMBL Y , SINGLE 3041A10011G 3041A10011G 3041A10011G R 130910 CABINET ASSEMBL Y , SINGLE 3091A10020B 3091A10020B 3091A10020B R 135312 GRILLE ASSEMBL Y.
P/NO:3828A20118B April, 2002 Printed in Korea.
Ein wichtiger Punkt beim Kauf des Geräts LG Electronics LWJ0561ACP/AAG (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie LG Electronics LWJ0561ACP/AAG noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für LG Electronics LWJ0561ACP/AAG - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von LG Electronics LWJ0561ACP/AAG reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über LG Electronics LWJ0561ACP/AAG erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon LG Electronics LWJ0561ACP/AAG besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von LG Electronics LWJ0561ACP/AAG verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit LG Electronics LWJ0561ACP/AAG. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei LG Electronics LWJ0561ACP/AAG gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.