01/08 *2P0108* Page 1 505,201M *P505201M* RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE 2006 Lennox Industries Inc. Dallas, Texas, USA Table of Contents Shipping & Packing List 1 . . . . . . . . . . . . . . . . . . . . . . . . . Unit Dimensions 2 .
HORIZONTAL SUPPLY AIR OPENING BACK VIEW END VIEW TOP VIEW A B FRONT VIEW HORIZONTAL RETURN AIR OPENINGS (2) C L FG H J K D E E D DOWN−FLOW SUPPLY AIR OPENING DOWNFLOW RETURN AIR OPENING E D E D END .
Page 3 Parts Arrangement General These installation instructions are intended as a general guide only, for use by an experienced, licensed contractor (or equivalent). The 15CHAX units are single−package electric units designed for outdoor installation o n a rooftop or a slab.
Page 4 For installation on combustible material. WARNING Product contains fiberglass wool. Disturbing the insulation in this product during installation, maintenance, or repair will expose you to fiberglass wool dust. Breathing this may cause lung cancer.
Page 5 Existing Common Vent Systems The 15CHAX packaged cooling units with auxiliary electric heat may replace an existing furnace which is being re- moved from a venting system commonly run with separate gas appliances. In this case, the existing vent system is likely to be too large to properly vent the remaining at- tached appliances.
Page 6 Filters Filters are not factory−supplied with the unit; however, optional internally installed filter kits are available. Filter kit 92 M 5 4 is used with 2, 2−1/2 and 3−ton units. Filter kit 92M55 is used with 3−1/2, 4 and 5−ton units.
Page 7 Unit must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electric Code, ANSI/NFPA No. 70 (latest edition) or CSA C22.2 Part 1 (latest edition). Power supply to the unit must comply with all applicable codes and NEC or CEC.
Page 8 Figure 7 15CHAX Series Packaged Electric Units Typical Wiring Diagram.
Page 9 Blower Control Board (A54) Electric shock hazard. Can cause injury or death. Before attempting to perform any service or m aintenance, turn the electrical power to unit OFF at disconnect switch(es).
Page 10 COOL The COOL jumper is used to determine the CFM during cooling operation. This jumper selection is activated for cooling when Y1 is energized. Th e blower motor runs at 80 percent of the selected air flow fo r the first 7−1/2 minutes of each cooling demand.
Page 11 System Operation Monitor (LSOM) The system operation monitor (A132) detects the most common fault conditions in the air conditioning system. Whe n an abnormal condition is detected, the module com- municates the specific condition through its ALERT and TRIP lights.
Page 12 Table 5 System Operation Monitor LED Troubleshooting Codes Status LED Condition Status LED Description Status LED Troubleshooting Information Green Power" LED ON Module has power 24VAC control power is present at the module terminal.
Page 13 Unit Start−Up and Operation Each 15CHAX packaged cooling unit is factory−charged with R−410A refrigerant. The compressor is hermetically sealed, internally sprung and base−mounted with rubber−insulated hold−down bolts. Pre−Start Check List: 1 − M a ke sure refrigerant lines do not rub against the cabi- net or each other.
Page 14 Condenser Fan Clearances The top of the condenser fan should be 1−1/2 inches from the bottom of the top grille. This dimension should be checked and the fan should be adjusted accordingly any time servicing of the outdoor fan system is required.
Ein wichtiger Punkt beim Kauf des Geräts Lennox International Inc. 15CHAX Series (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Lennox International Inc. 15CHAX Series noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Lennox International Inc. 15CHAX Series - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Lennox International Inc. 15CHAX Series reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Lennox International Inc. 15CHAX Series erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Lennox International Inc. 15CHAX Series besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Lennox International Inc. 15CHAX Series verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Lennox International Inc. 15CHAX Series. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Lennox International Inc. 15CHAX Series gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.