Benutzeranleitung / Produktwartung SOLANA-BK des Produzenten Lennox Hearth
Zur Seite of 26
SOLANA-BK SOLANA-BN SA VE THESE INSTRUCTIONS FOR FUTURE REFERENCE This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation.
2 W ARNING NEVER use gasoline, gasoline- type lantern fuel, kerosene, charcoal lighter fluid, naphtha, engine oil or similar liquids to start or “freshen up” a fire in this fireplace. Keep any flammable liquids a safe distance from the fireplace at all times.
3 T AB LE O F C O NT E NT S Safety Rules .......................................Page 2 Introduction .......................................Page 3 Parts Required ..................................Page 3 Optional Equipment ............................Page 3 EP A Qualified .
4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Building A Fire (starting and maintaining a fire) T o start a fire, place several crumpled up balls of newspaper in the firebox. Place small dry pieces of kindli ng on top of the paper , criss-c rossing the kindling so that there are air spaces in between.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 5 Figure 1 - Outside air Register D. Wet wood Wet or tarred wood will smoulder and smoke instead of burning properly . Y our dealer can help you determine if you have properly seasoned wood for burning.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 6 Caution: It is necessar y to remove the baffle from the top of the firebox before cleaning the chimney . Dealing With a Chimney Fire Regular chimney maintenance and inspection can preve nt chim ney fires.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 7 REFRACTORY REPLACEMENT The intense heat of the fire will normally cause hairline cracks in the refractory . These cracks can be minimized by proper curing as described in “First Fires”. They will not normally dimin- ish the effectiveness of the refractory .
8 Marginal Location Wind Direction Location Not Recommended Outside Air Intake Facing the Wind Location Not Recommended Location Recommended Figure 6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. FIREPLACE INST ALLA TION Locating The Solana Fireplace A.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 9 W ARNING When using a gas burner , it is mandatory to keep the chimney outside air register opened.
Non-Combustible Material NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 10 Mantel A wood mantel, if installed, must be at least 48" (1.2 m) above the base of the fireplace ( see Figure 8B ) . There is no restriction regarding the length or the width of the mantel.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 11 42” (1067 mm) 43” (1092 mm) 43” (1092 mm) 27-1/2” (699 mm) 10-5/8” (270 mm) 33” (838mm) 42-1/2” (1080 mm) 17-1/8” (435 mm) 28-5.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 12 Fireplace Side Insulated Chase Construction Fireplace Facing The fireplace should be framed using 2" x 3" (50mm x 75mm) or heavier lumber . Figure 9 on Page 11 shows the general framing layout.
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 12 - External Air Intake (Detail A) (Detail C) Outside Air Assembly (Fireplace and AC Chimney) The outside air assembly is mandator y for the fireplace and the AC chimney . During operation, the fireplace requires air for combustion and draws air out of the house.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 14 INST ALLA TION OF THE BLOWER KIT MODEL UZY5 NOTE: This blower kit can easily be installed when the fireplace has a pre-installed junction box. Y ou just have to plug them in. Rating: 120 Volts, 60Hz, .
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. CHIMNEY SYSTEM GENERAL INFORMA TION The Sol ana™ firep lace is listed only with Security Chimneys™ Interna- tional Ltd. chimney systems, models ASHT+ 8", S-2100+ 8", or AC 8".
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 16 CHIMN EY INST ALLA TION INSTR UCTIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 19 ) . Use a plumb-bob to line up the center of the holes.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 17 Roof Down Slope Hole Size SLOPE ASHT+ S-2100+ AC Roof Pitch 8" 8" 8" 0 * 14-3/8" (365mm) 16" (406mm) 15" (380mm) .
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 18 Figure 24 Ch im ney 8” Elbow Offset & Height One Length Between Elbows T wo Lengths Between Elbows 8” 12” 18” 24” 36” 48" .
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 19 ANGLED WALL RADIA TION SHIELD (RSM+, RSMI30, RSMI45) When traversing a combustible wall with the chimney at a 30° or 45° angle, an angled firestop and/or wall radiation shield must be installed.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 20 Figure 29 - S-2100 Chimney Adaptor Chimney Adaptor - Canada only CHIMNEY ADAPTOR (S-2100+ / HT6000+) CANADA ONL Y The fireplace is normally supplied with a chimney adaptor suitable for the ASHT / HT6103+ chimney .
21 Fireplace Model Solana™ - Approved Venting Components 8" Diameter Chimney - Model ASHT+, S-2100+, HT6000+, HT6103+ or AC manufactured by Security Chimneys International only . Notes: 1. (Projet NovaT emp™) HT6000+ is equivalent to S-2100+ 2.
22 Se cu re T em p™ A SH T+ H ig h T em p. I ns ul a te d St ai nl es s St ee l Ch im ne y 8" D iam ete r , Lis ted t o C AN / UC L-S 60 4 a nd UL -1 03H T a t 120 0° F Description Cat./ Part No. Lengths and Misc. Chimney Components 8" Length, 8" Dia.
23 CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation; Side wall: 18” (457 mm) Ceiling: 7 feet (2135 mm) measured from the base of the fireplac.
24 Item # Description Cat. No. 1 Refractory Baffle PR-SR2028 2 Back Refractory PR-SR2027 3 Right Side Refractory PR-SR2025D 4 Left Side Refractory PR-SR2025G 5 Bottom Refractory PR-SR1722 6 Front Ref.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 25 REPLACEMENT P ARTS - SOLANA™ P A I N T 18 1 2 3 4 6 7 9 8 10 10 12 11 13 15 16 14 17 19 20 21 22 5.
26 Y our Fireplace's Model Number ________________________________________ Y our Fireplace's Serial Number ________________________________________ The Date On Which Y our Fireplace Was Inst.
Ein wichtiger Punkt beim Kauf des Geräts Lennox Hearth SOLANA-BK (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Lennox Hearth SOLANA-BK noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Lennox Hearth SOLANA-BK - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Lennox Hearth SOLANA-BK reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Lennox Hearth SOLANA-BK erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Lennox Hearth SOLANA-BK besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Lennox Hearth SOLANA-BK verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Lennox Hearth SOLANA-BK. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Lennox Hearth SOLANA-BK gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.