Benutzeranleitung / Produktwartung LMBV-42RMP des Produzenten Lennox Hearth
Zur Seite of 16
1 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INST ALLA TION INSTRUCTIONS 42" B-VENTED GAS APPLIANCES P/N 850,041M REV. A 02/2007 Millivolt Models Electronic Models LMBV-42RMN LMBV -42REN LMBV-42RMP FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicin- ity of this or any other appliance.
2 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TABLE OF CONTENTS Introduction ..................................... page 2 General Information ......................... page 2 Massachusetts and New York Requirements ...............................
3 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea.
4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. CLEARANCES Minimum clearance to combustibles for the ap- pliance is as follows: sides and back - 0" (0 mm), floor - 0" (0 mm), adjacent wall - 0" (0 mm), ceiling - 64" (1625 mm). Venting Gas Vent Rule – Gas vent caps are not permit- ted within 8 feet (2.
5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. FRAMING SPECIFICATIONS Figure 4 Figure 5 Figure 6 Framing Dimensions Note: All framing dimensions calculated for 1/2" dry wall at the appliance face. If sheathing the chase or finishing with other thickness materials, calculations will need to be made.
6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. All appliances are equipped with a gas flex line and shutoff valve attached directly to the gas control valve.
7 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 11 Step 5. Field Wiring – Refer to Section A for millivolt appliances and Section B for electronic appliances. A. Millivolt Wiring – The gas valve has been set in place and has been pre-wired at the factory.
8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 14 Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be wired to a terminal that is opposite (across the outlet) the point where the white supply wire is connected.
9 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Replace logs if removed for pilot inspection. To light the burner; turn “ON” the remote wall switch and rotate the gas valve control knob counterclockwise to the “ON” position (“ON” will be to the left hand side of the valve).
10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. When satisfied that the appliance operates properly, proceed to finish the installation. Leave the control knob/lever in “ON” position and turn the remote switch “OFF.” Replace the refractory access panel.
11 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Fireplace Opening Spacer Finished Wall Header 1 2 3 4 5 6 7 8 9 10 11 12 9 10 11 12 Combustible Mantel Clearances Inches Min. Height of Mantel Above Fireplace Opening Max.Length of Mantels Three mantels are shown (dark gray elongated rectangles)- one, 1 ¹⁄₂ in.
12 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Gas Conversion Kits In Canada THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.
13 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Step 5. Attach manometer to the manifold side pressure test fitting and verify manifold pressure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column (2.49 kPa) for propane gas.
14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NOTE: THIS PAGE INTENTIONALLY LEFT BLANK..
15 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NOTE: THIS PAGE INTENTIONALLY LEFT BLANK..
16 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Printed in U.S.A. © 2006 by Lennox Hearth Products P/N 850,041M REV. A 02/2007 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Ein wichtiger Punkt beim Kauf des Geräts Lennox Hearth LMBV-42RMP (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Lennox Hearth LMBV-42RMP noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Lennox Hearth LMBV-42RMP - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Lennox Hearth LMBV-42RMP reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Lennox Hearth LMBV-42RMP erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Lennox Hearth LMBV-42RMP besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Lennox Hearth LMBV-42RMP verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Lennox Hearth LMBV-42RMP. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Lennox Hearth LMBV-42RMP gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.