NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 1 36" Wood Burning Fireplaces P/N 850,048M REV. N/C 01/2007 CR-3835R CR-3835L MODELS This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 TABLE OF CONTENTS Safety Rules .................................... page 2 Tools and Building Supplies ............ page 2 Precautions ..................................... page 2 Introduction .......
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Figure 1 TYPICAL INSTALLATION *Construction Materials: • framing materials • paneling • particle board • flooring • dry wall • etc.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 Figure 2 Chimney Height The total height of your completed fireplace sys- tem from the surface the fireplace rests on to the chimney top must not exceed 50' (15.24 m) and must also meet minimum height requirements.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 Note: Install the hearth extension only as illus- trated. The safety strips should extend from front of the fireplace at least 1 ¹⁄₂ " and should extend to be at least flush with the sides.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 FIREPLACE SPECIFICATIONS Figure 11 17 1/2" (445mm) 32 7/8" (835mm) 21" (533m) 6" (152mm) 40 1/2" (1029mm) 37 3/8" (949m.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 FRAMING SPECIFICATIONS Figure 15 Figure 14 Figure 12 Figure 13 Figure 16 Framing Dimensions for Ceiling Flue Type A B FTF8 Vertical 16 ¹⁄₂ ".
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 Step 8. Fireplace should be secured to side framing members using the full length nailing tabs at the top and bottom of the fireplace front face.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 CHIMNEY 30 ° OFFSET THROUGH FLOOR OR CEILING It may be necessary to assemble the chimney at 30 ° when passing through the floor or ceiling area. Use the F8FS30-2 firestop spacer as shown in Figures 21 and 22 .
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 Note: If chimney extends more than 8' above roof surface, guy wires are also recommended. Use three (3) guy wires, attach to locking band assembly, extend and secure to roof in a trian- gular pattern (Figure 30 ).
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 11 Figure 32 Figure 33 This suggestion is provided in the interest of better operation. If the terminations are located too close to each other, smoke may migrate from one flue into the other. CTD 18" 18" 24" 24" CTDT CTDT Less Than 10' 3' Min 2' Min.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 The offset and return elbows may be attached together, or a section or sections of chimney may be used between, but do not exceed 20' in total length between elbows. If sections of pipe exceed 10' between elbows, a chimney stabi- lizer must be used at the midpoint ( Figure 34 ).
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 FTF8 VERTICAL ELEVATION CHART 10 ¹⁄₄ 01 0 ¹⁄₄ 1 0 0 0 0 – 0.26 16 ¹⁄₄ 14 ¹⁄₄ 0 1 0 0 0 – 0.41 22 ¹⁄₄ 11 0 ¹⁄₄ 0 0 1 0 0 – 0.57 26 ¹⁄₂ 22 ¹⁄₂ 1 1 0 0 0 – 0.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 FTF10 VERTICAL ELEVATION CHART 11 0 11 1 0 0 279 0.28 17 1 5 0 1 0 432 0.43 21 ¹⁄₄ 19 ¹⁄₄ 2 0 0 540 0.54 27 ¹⁄₄ 23 ¹⁄₄ 1 1 0 692 0.69 33 ¹⁄₄ 29 ¹⁄₄ 0 2 0 845 0.85 35 2 11 0 0 1 889 0.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 FTF8 OFFSET ELEVATION CHART (With FTF8-SS Starter Section) A B FTF10/8-ES30 FTF8-SS Number of FTF8 A B Offset Height Offset/Return Starter FTF8-S4 C.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 16 Figure 36 Figure 37 Figure 38 Chimney Section Joints No. 8 x 1/2" SMS Screws Required At Every Joint Past 6' No Screws Required In Joints .
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 Figure 40 Gas Line Connection Install a ¹⁄₂ " (13 mm) gas supply line through fireplace wall for connection to a decorative gas appliance inside the firebox. Outside, the gas supply line must connect to a gas shut-off valve usually recessed flush into the wall or floor.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 Glass Doors If glass doors are to be installed on these fireplaces, refer to specific installation instruc- tions packed with the glass doors. Use only the doors that are listed for use with these fire- places.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19 Figure 43 Hearth Extension Dimensions A 20" (508 mm) B 38" (965 mm) C 8" (203 mm) D 20" (508 mm) E 12" (305 mm) Answer - The minimum required thickness of the Micore 160 is .
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 20 FINISH TO YOUR TASTE There are a wide variety of “finished looks” for these fireplaces, from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings. Only noncombustible materials like stone, tile, brick, etc.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 21 63L30 F8FS30 63L32 F8FS30-2 Firestop Spacer (30 ° ) 63L37 F10FS30-2 63L22 FTF8-ES30 Offset/ Return 63L23 FTF10-ES30 Package (30 ° ) 22154 FTF10/8-ES30 INSTALLATION COMPONENTS The following items are available for use in the installation of this appliance.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 22 63L42 FTF8-CTD Round Termination 63L43 FTF10-CTD Chase Termination 63L48 FTF8-CT1 (Square) 63L49 FTF10-CT1 Chase Termination 63L45 FTF8-CTDT (Round).
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 23 NOTES:.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 24 Printed in U.S.A. © 2007 by LENNOX HEARTH PRODUCTS P/N 850,048M REV. N/C 01/2007 1110 West Taft Avenue Orange, CA 92865 The manufacturer reserves t.
Ein wichtiger Punkt beim Kauf des Geräts Lennox Hearth CR-3835R (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Lennox Hearth CR-3835R noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Lennox Hearth CR-3835R - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Lennox Hearth CR-3835R reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Lennox Hearth CR-3835R erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Lennox Hearth CR-3835R besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Lennox Hearth CR-3835R verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Lennox Hearth CR-3835R. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Lennox Hearth CR-3835R gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.