-1- INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400.
-2- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documen- tation may be reproduced in any form or by any means or used to make any directive work (such as translation or transformation) without per- mission from KTI Networks Inc. KTI Networks Inc.
-3- The information contained in this document is subject to change without prior notice. Copyright (C) All Rights Reserved. TRADEMARKS Ethernet is a registered trademark of Xerox Corp. FCC NOTICE This device complies with Class B Part 15 the FCC Rules.
-4- T a ble of Contents 1. Introduction ......................................................... 5 1.1 Features ........................................................................................ 6 1.2 Specifications ............................
-5- 1. Introduction The industrial 1000BASE-T to 1000BASE-X media converter series pro- vides industrial strength Ethernet copper-to-fiber media conversion, allow- ing for 1000Base-T-to-1000Base-X over multi-mode or optional single- mode fiber optical media.
-6- 1.1 Features • Gigabit copper to fiber conversion: 1000Base-T-to-1000Base-SX/LX over multimode or single-mode fiber • SFP design : For flexibility , a n SFP (Mini-GBIC) connector is provided for the fiber port to accommodate any type of SFP fiber transceiver when needed.
-7- 1.2 Specifications This figure shows the important components of the converter:.
-8- T wisted-Pair Interfa ce (Copper Por t) Connector Shielded RJ-45 Signal Compliance IEEE 802.3ab 1000BASE-T std. Pin Assignments Auto MDI/MDI-X detection Data Speed 1000Mbps Duplex Mode Half-duplex.
-9- DC Power Interface Interface Screw-type terminal block 1. T wo pairs for power wire ca sca ding 2. One pair for power failure relay output DC Jack (-D6.3mm/+D2.0mm) Operating Input V oltages +7V ~ +30V(+5%) Power c on s um ption 2.25W @+7.5VDC input 2.
-10- Certificate F C C Part 15 Class B CE/EMC EMI EN50081-1 Class B EMS EN55024 CE/L V D Safe ty E N 60950 EN 50081-1/1992 : EN55022:1994/A1:1995/A2:1997 EN61000-3-2:2000 EN61000-3-3:1995/A1:2001 EN 5.
-11- 1.3 Special Functions Auto MDI/MDI-X Function This function allows the copper port to auto-detect the twisted-pair sig- nals and adapts itself to form a valid MDI to MDI-X connection with the remote connected device automatically .
-12- Far End Fault Function The fiber port is facilitated with this function. When the fiber port detects a link failure on its receiving circuitry , it will send out a n FEFI (Far End Fault Indication) signal to the remote connected device to indicate a remote fault is detected.
-13- 2. Installation 2.1 Unpacking Check that the following components have been included: • Information CD • The Media Converter unit • DIN-rail mounting bracket If any item is found missing or damaged, please contact your local reseller for replacement.
-14- 2.2 Safety Cautions T o reduce the risk of bodily injury , electrical shock, fire, a nd da mage to the equipment, observe the following precautions. • Do not service any product except as explained in your system documentation. • Opening or removing covers may expose you to electrical shock.
-15- 2.3 DIN-Rail Mounting In the product package, a DIN-rail bracket is installed on the device for mounting the converter in a industrial DIN-rail enclosure. The steps to mount the device onto a DIN rail are: 1 . Install the mounting bracket onto the device unit as shown below: 2 .
-16- The final mechanical dimensions after installing DIN rail mounting bracket are:.
-17- 2.4 Panel Mounting The device is provided with an optional panel mounting bracket. The bra cket support mounting the device on a pla ne surfa ce securely . The mounting steps are: 1 . Install the mounting bracket on the device unit. 2 . Screw the bracket on the device unit.
-18- The screw locations and final dimension are shown below:.
-19- 2.5 Applying Power The power specifications of the device are: Operating V oltage + 7 ~ +30VDC Power Consumption Max. 2.5W @30VDC The device provides two types of power interfaces, terminal block and DC power ja ck for rece iving DC power input from external power supply .
-20- Power wires: 24 ~ 12A W G (IEC 0.5~2.5mm 2 ) Install the power source wires with the plug properly . Screw the wire with plug securely . Then, plug in DC1 conta cts. If cascading the power to next device is needed, install the power wires and plug for another switch.
-21- Using DC Power Jack DC Jack Connector: Jack D 6.3mm D 2.0mm AC Power Adapters: Optional commercial rated adapters are available for purchasing. Rated AC120V/60Hz DC7.5V 1A Rated AC230V/50Hz DC7.5V 1A Rated AC100V/50-60Hz DC7.5V 1A Rated AC240V/50Hz DC7.
-22- 2.6 Power Failure Relay Output The device provides a relay output to report power failure event to a remote alarm monitoring system. The replay output is provided with two contacts labeled PF+ and PF- in the terminal block interface. Use the provided 2P terminal plug for signal wiring and plug into the PF+/ - contacts.
-23- 2.7 Ma king T wisted Pair Copper Port Conne ction Copper port is featured to support connection to : • Auto-negotiation devices • Auto-negotiation incapable 10BASE-T devices • Auto-negotiation incapable 100BASE-TX devices Network Cables 1000BASE-T : 4-pair UTP Cat.
-24- 2.8 Making Fiber Port Connection The mini-GBIC (SFP) port must be installed with an SFP fiber trans- ceiver for making fiber connection. The device may come with an SFP tra nsceiver pre-installed when it is shi pped from factory . Installing SFP Fiber T ra nsceiver Turn off the power to the device.
-25- 3 LED Indicators The following figure shows the locations of the configuration switches and LED indicators: 3.1 LED Indicators LED DISPLA Y ST A TE INTERPRET A TION P W R Power status O N The device is powered on. O F F The device is powered off.
-26- Appendix: Model Optical Specifications The media converter series provides the following fiber options: Model Specifications Reference Operating KCD-400-xx FX W avelength Fiber Dista nce T e mpera tur e -SX L C 850nm 50/125 MMF 500m -20 ~ 70 o C 62.
Ein wichtiger Punkt beim Kauf des Geräts KTI Networks KCD-400 Series (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie KTI Networks KCD-400 Series noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für KTI Networks KCD-400 Series - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von KTI Networks KCD-400 Series reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über KTI Networks KCD-400 Series erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon KTI Networks KCD-400 Series besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von KTI Networks KCD-400 Series verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit KTI Networks KCD-400 Series. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei KTI Networks KCD-400 Series gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.