® BATTERY SYSTEM DIONIC ® 90 lithium ion Digital Battery OWNER’S MANUAL.
TABLE OF CONT ENTS IMPORTANT READ AND UNDERSTAND T HIS MANUAL BEFORE OPER ATION .................................................................... 1 INTRODUCTION .............................................................................. 2 FEATURES .
1 IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE OPERATION The InterActive 2000 Dionic 90 battery lithium ion chemistry delivers a higher power to weight ratio than NiCd & NiMH. However, all lithium ion batteries have more sensitive char ging and discharging param eters and require longer charge times (2-5 hours).
2 INTRODUCTION The development of this new DIONIC 90 battery sy stem has been made possible through the incorporation of the pioneering InterActive technology of the Anton/Bauer Digital system with the very latest lithium ion cell formulations.
3 FEATURES 1. Microprocessor Fu el Computer - Accurately monitors the energy in the battery with programs that take into account battery age, self discharge, charge/discharge rate, operating conditions and previously experienced charge/discharge cycles.
4 CHARGING DIONIC 90 BATTERIES • DO NOT ATTEMPT TO CHARGE THIS BATTERY WITH ANY CHARGER OTHER THAN THE ANT ON/BAUER InterActive 2000 OR T SERIES CHARGERS SPECIFIED IN THIS MANUAL. • Allow the battery to reach a steady green (LifeS aver ® ) mode before using for the first time.
5 NOMINAL CHARGE TIMES FOR DIONIC 90 Charge Le v el LED Indicators 90% Flashing Green 100% Steady Green Dual 2722 (2 batteries simultaneously) 2hrs. 3hrs. InterActive 2000 Pow erCharger (Quad/Dual – 2702/2701/2700) (Quad/Dual – 2401/2400) 2 hrs. 3 hrs.
6 The DIONIC 90 features an all NEW “RealTime” LCD display providing on-the-fly remaining run time estimates in 15 minute increm ents as well as simultaneously providing remaining capacity information using the traditional “Fuel Gauge” approach.
7 -The large numbers 1, 2 or 3 indicate remaining hours under current load (only one number will display at any one time) -The pie chart numbers ( 15, 30, 45, or 60) indicate remaining minutes under current load.
8 If the SIDE BARS (only) flash AND other icons are lit and not flashing, this indicates the battery has requested to be fully charged and discharged in order to update its “learned capacity”. This “learning” should typically occur during normal equipment operation.
9 RealTime Display Indications • When the DIONIC battery is being charged remaining runtime is not displaye d. • Rem aining run time is calculated using the present available battery capacity and a constantly updated accurate measurement of the present load on the battery.
10 • W hen the battery is completely discharged the LCD will flash the 15 minute icon and the ‘RES’ bar until the battery is returned to a charger. • If the protection electronics detect a low battery voltage condition (any one cell reaches roughly 2.
11 OPERATING GUIDELINES 1. Keep batteries cool or at room temp eratures whenever poss ible. Sustained elevated temperatures are the primary reason for premature failure of lithium ion batteries: a. Charging - Charge batteries at room temperature. In warm climates keep chargers in air conditioned rooms for best performance.
12 4. Low voltage batteries can also be caused by allowing batteries to remain off the charger for extended periods causing the LCD display to be blank, indicating that the electronic circuitry has removed all load from the battery cells – including the display.
13 SERVICE In the event a DIONIC 90 battery fails to deliver acceptable performance, it must be returned to the Anton/Bauer. No ot her facility is qualified and equipped to service the InterActive 2000 DIONIC 90 ba tteries and calibrate the electronic components and sensors.
14 PRECAUTIONS 1. Do not expose this battery to high temperatures (above 50°C/120°F). This includes storage in direct sunlight , in cars in hot weather, or in close proximi ty to heating devices. This may cause electrolyte leak age, impaired p erformance and shorten ing of battery s ervice life.
15 DIONIC 90 BATTERY SPECIFICATIONS OUTPUT VOLTA GE 14.4v Nominal 12.4 ~ 16.8v Operating CA PA CITY (CELL CA PA CITY) 90 WH Nominal (6.3 AH Rated) FUSE Internal 8amp RECOMMENDED OPERA TION 15 - 50 watts 1 (MAXIMUM DISCHARGE RATE) (90 watts) 2 TYPICA L RUN-TIME @ 20w - 4 ½ hrs.
16 LIMITED WARRANTY This w arranty for the ba ttery product specif ied in this doc ume nt (“ Product”) is g iven by A nton/Bauer , Inc. (“Anton/Baue r”), 14 Progres s Driv e, Shelton, Conne cticut 06484.
17 Dangerous Goods Regulations 49C FR Parts 100-185, Air Transport Association (IATA) and the International Civil Aviation Organization (ICAO) regulations a pply to all lithium ion battery transport.
7595-0243 Rev M The power behind the best cameras capturing the best im ages in the world. sm The following are trademarks of Anton/Bauer, Inc.: ACS, ADM, All Chem, Anton/Bauer, Anton/Bauer logo and p.
Ein wichtiger Punkt beim Kauf des Geräts Anton/Bauer DIONIC 90 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Anton/Bauer DIONIC 90 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Anton/Bauer DIONIC 90 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Anton/Bauer DIONIC 90 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Anton/Bauer DIONIC 90 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Anton/Bauer DIONIC 90 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Anton/Bauer DIONIC 90 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Anton/Bauer DIONIC 90. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Anton/Bauer DIONIC 90 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.