Manual P/N 820-1669 Rev . A For questions concerning your Smoke and Carbon Monoxide Alarm, please call our Consumer Hotline at 1-800-880-6788. User’ s Guide for Model KN-COPE-I • 120 V AC (Interco.
When the carbon monoxide alarm sounds: If alarm signal sounds: 1) Operate the test/reset button 2) Call your emergency services (Fire Dept. or 911) 3) Immediately move to fresh air - outdoors or by an open door/window . Do a head count to check that all persons are accounted for .
NEVER IGNORE THE SOUND OF THE ALARM! Determining what type of alarm has sounded is easy with your Kidde Combination Smoke/CO Alarm. The voice mes- sage warning system will inform you of the type of situa- tion occurring. Refer to the Features section on page 4 for a detailed description of each alarm pattern.
What T o Do When The Alarm Sounds! • Go to your predetermined meeting place. When two people have arrived one should leave to call 911 from a neighbor’ s home, and the other should stay to perform a head count. • Do not reenter under any cir cumstance until fire officials give the go ahead.
Introduction ............................. .1 Product View ............................. .2 Features ................................. .4 Operating/Installation Instructions Step 1: Installing Batteries . . . . . . . . . . . . . . . . . . . 8 Step 2: Installation Instructions: A.
Thank you for purchasing the Kidde Combination Photoelectric Smoke and Carbon Monoxide Alarm model KN-COPE-IB. This alarm is suitable as a Single Station and/or Multiple Station (24 devices) alarm.
FRONT T est/Reset/Hush Button Green& Red LED (Light Emitting Diode) Batter y Compartment Alarm Sounder 2 Product V iew V oice Speaker.
BACK Mounting Bracket T amper Resist Latch 3 Product V iew Battery Door T amper -Resist Slide.
• Permanent independent smoke and carbon monoxide sensors . • Smoke alarm takes precedence when both smoke and car- bon monoxide are pr esent. • Alarm/V oice message warning system that alerts y.
• After seven (7) years of cumulative power up, this unit will “chirp” once every 30 seconds. This is an "operational end of life" feature which will indicate that it is time to r eplace the alarm. • Loud 85 decibel alarm • HUSH Control Featur e that silences the unit during nuisance alarm situations (see page 16).
Smoke Alarm The smoke alarm monitors the air for products of combus- tion that are pr oduced when something is burning or smol- dering. When smoke particles in the smoke sensor reach a specified concentration, the alarm/voice message warning system will sound, and be accompanied by the flashing red LED light.
• Smoke alarms cannot provide an alarm if smoke does not reach the alarm. Ther efore, smoke alarms may not sense fires starting in chimneys, walls, on r oofs, on the other side of a closed door or on a differ ent floor . • If the alarm is located outside the bedroom or on a dif fer- ent floor , it may not wake up a sound sleeper .
Step 1 Installation Guide: IMPORT ANT : THIS ALARM MUST BE MOUNTED ON A CEIL- ING OR W ALL. IT W AS NOT DESIGNED FOR USE AS A T ABLETOP DEVICE! INST ALL ONL Y AS DET AILED! A. Recommended Installation Locations: Kidde recommends the installation of a Smoke/CO Alarm in the following loca- tions.
Sloped Ceiling Installation: The following information is from the National Fir e Protection Association and is listed in Fir e Code 72. Install Smoke Alarms on sloped, peaked or cathedral ceilings at, or within 3 ft (0.9m) of the highest point (measured horizon- tally).
B. Where Not to Install: Do not install in garages, kitchens, furnace rooms or bathrooms! INST ALL A T LEAST 5 FEET A WA Y FROM ANY FUEL BURNING APPLIANCE.
11 Operating and Installation Instructions Step 2 Wiring Instructions: Wiring Requirements • This smoke alarm should be installed on a U.L. listed or recognized junction box. All connections should be made by a qualified electrician and all wiring used shall be in accordance with articles 210 and 300.
CO, Smoke/CO Combination, heat, etc.). This Smoke/CO combination alarm must be counted as a smoke alarm when determining the number of units on an intercon- nect line.
Operating and Installation Instructions 13 2. Remove the mounting bracket from the back of the alarm by holding the mounting bracket and twisting the alarm in the direction indicated by the “OFF”arr ow on the alarm cover .
9. Pull the Battery Pull T ab (yellow tab protruding from unit) completely out of unit. This will automatically connect the battery . Step 4: T esting the Alarm CAUTION: Due to the loudness (85 decibels) of the alarm, always stand an arms length away from the unit when testing.
Operating and Installation Instructions 15 • This alarm is interconnect compatible with the following alarms and accessories: – Smoke alarms: 1235, 1275, 1276, 1285, 1296, i12020, i12040, i12060, i12080, PE120, PI2000, KN-COSM-IB, KN-COSM-I, KN-SMFM-i and RF-SM-ACDC.
Alar m/Peak Level Memory If the green LED is blinking once every 16 seconds, the unit has detected a hazardous condition. If the unit has detected a CO level of 100 PPM or greater , pushing the T est/Reset button will result in a voice message “Caution, carbon monoxide previously detected”.
Operating Instructions 17 alarm, a CO alarm, a low battery mode chirp and a unit error mode chirp. Green LED T he green LED will flash as described below under the fol- lowing conditions: – Standby Condition (powered by AC and battery back- up): The LED will be constantly on, but will flicker every 30 seconds when a CO reading is taken.
This alarm also has a battery carrier tamper resist featur e, which helps prevent the battery carrier fr om being opened. This feature is ef fective in preventing the r emoval of the battery from this device (which will r ender the unit inopera- ble during the loss of AC power).
Operating Instructions 19 NOTE: Before activating the battery carrier tamper resist featur e, make sure a fresh battery is installed in the unit and that the battery carrier is properly closed.
T o disconnect the AC power harness, squeeze the locking arms on the sides of the Quick Connector while pulling the connector away from the bottom of the alarm. If any form of battery failure is detected the r ed LED light will flash and the unit will “chirp” one time, followed by the warning message “LOW BA TTERY” .
21 Gold Peak 1604A. These batteries can be purchased at your local retailer . W ARNING! Use only the batteries specified. Use of differ- ent batteries may have a detrimental effect on the Smoke/CO alarm. A good safety measure is to r eplace the battery at least once a year , or at the same time you change your clocks for daylight saving time.
22 FEA TURE DESCRIPTION ON P AGE 17 FOR REMOV AL INSTRUCTIONS. • Never use detergent or other solvents to clean the unit. • A void spraying air freshener , hair spray , or other aerosols near the Smoke/CO Alarm. Do not paint the unit. Paint will seal the vents and interfere with the sensor’ s ability to detect smoke and CO.
23 General CO Information Carbon Monoxide (CO) is a colorless, odorless, and tasteless poison gas that can be fatal when inhaled. CO inhibits the blood’ s capacity to carry oxygen. Possible Sources CO can be produced when burning any fossil fuel: gasoline, propane, natural gas, oil and wood.
24 CO Safety Tips Every year have the heating system, vents, chimney and flue inspected and cleaned by a qualified technician. Always install appliances according to manufactur er’ s instructions and adhere to local building codes. Most appliances should be installed by professionals and inspected after installation.
poisoning indicate that while victims are awar e they are not well, they become so disoriented they are unable to save themselves by either exiting the building, or calling for assis- tance. Also, young children and household pets may be the first effected.
NFP A (National Fire Protection Association) For your information, the National Fire Pr otection Association’ s Standard 72, r eads as follows: Smoke Detection.
Consumer Product Safety Commission The Consumer Product Safety Commission (CPSC) r ecom- mends the use of at least one CO Alarm per household, located near the sleeping area.
28 SEVEN YEAR LIMITED W ARRANTY Kidde warrants that the enclosed alarm (but not the bat- tery) will be free fr om defects in material and workmanship or design under normal use and service for a period of seven years from the date of pur chase.
This alarm is not intended to alert hearing impaired indi- viduals. Service Information During the specified warranty period Kidde will repair or replace, at its discr etion any defective Kidde Combin.
U.S. Patents 6,160,487 and 6,753,786 2505-7201-00 QUESTIONS OR FOR MORE INFORMA TION Call our Consumer Hotline at 1-800-880-6788 or contact us at our website at www .
Ein wichtiger Punkt beim Kauf des Geräts Kidde KN-COPE-I (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Kidde KN-COPE-I noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Kidde KN-COPE-I - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Kidde KN-COPE-I reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Kidde KN-COPE-I erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Kidde KN-COPE-I besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Kidde KN-COPE-I verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Kidde KN-COPE-I. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Kidde KN-COPE-I gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.