OWNER'S MANUAL MODEL NO. 625.384700 Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. If you have questions when installing, operating or maintaining your reverse osmosis system, call this toll-free number.
- WARRANTY- 1 li I I /liJ I Ill li I I _ I Ill I / I lill_ I FULL WARRANTY ON REVERSE OSMOSIS DRINKING WATER SYSTEM = = (except filter cartridges and R.
- TABLE OF CONTENTS - Where To Install the RO System ........ 4 Tools and Materials Needed ........... 4 Installation Steps .................... 5- 9 Cold Water Supply .................. 5 Drain Adapter ..................... 6 Faucet .................
- WHERE TO INSTALL THE RO SYSTEM - The RO assembly and storage tank is designed for installation under the sink, usually in the kitchen or bathroom. The RO assembly mounts on a wall sur- face, or can lay on the cabinet floor next to the storage tank. Hanger washers and wood screws are included for cabinet wall mounting.
- STEP 1: INSTALL COLD WATER SUPPLY FITTING - Check and comply with local plumbing codes as you plan, then install a cold feed (supply) water fitting. The fitting must provide a leak- tight connection to the RO 1/4" tubing (see FIG. 8, page 8). A typical connection using the included water supply fitting is shown in FIG.
- STEP 2: INSTALL DRAIN ADAPTER - • Note: Running the drain tubing directly to a floor drain, sump, standpipe, laundry tub, etc., as shown on page 18, is preferred. However, if that is not pos- sible or practical, the included drain adapter installs in the sink drain pipe, always above or ahead of the p-trap (FIG.
- STEP 3: INSTALL FAUCET (cont.)- B. ASSEMBLE FAUCET 1. If not already assembled, install the rubber washer, spacer, flat (or lock) washer and hex nut onto the threaded faucet stud. 2. Apply Teflon tape to the end of the faucet stud. Turn the tubing adapter with a blue collet onto the stud and hand tighten, then wrench 1/4 turn only.
- STEP 5: INSTALL STORAGE TANK, MAKE REMAINING TUBING CONNECTIONS - 1. CONNECT DRAIN TUBING, FAUCET TO DRAIN ADAPTER: Referring to FIG. 8, run the loose section (connected to faucet barb fitting) of black 3 / 8" tubing from the faucet to the drain adapter, with a black collet, installed on page 6.
- STEP 6: SANITIZING, PRESSURE TESTING & PURGING - SANITIZING Sanitizing is recommended upon installation of the RO system, and after servicing inner parts. It is im- portant for the service person to have clean hands while handling inner parts of the system.
- HOW YOUR REVERSE OSMOSIS SYSTEM WORKS - PREFILTER Water from the cold supply pipe enters the RO as- sembly prefilter first (FIG. 8 and schematic below).
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - To keep your reverse osmosis system operating and producing high quality water, you must make sure supply water is always within the limits shown in the specifications. Good supply water helps to assure longer life from the RO membrane cartridge, prefilter and postfilter cartridges.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - 2. Press inward while turning the RO cap to the left (_) to remove from the bracket/membrane housing. 3. Use a pliers, or heavy wire made into a hook, to pull the RO cartridge from the housing. Note: Sanitizing is recommended after servicing in- ner parts of the system (see page 9).
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - TUBING CONNECTION (continued) If tubing other than tubing supplied with the system is used, be sure it is of high quality, exact size and roundness with a smooth surface. AUTOMATIC SHUTOFF SERVICE If the shutoff assembly requires service, be sure to reassemble parts exactly as shown in FIG.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - REVERSE OSMOSIS SYSTEM CARE GUIDE MODEL NO. 625.384700 1. AT LEAST every 6 months, replace the prefilter and postfilter cartridges.
- DIMENSIONS and SPECIFICATIONS - 15" Supply water pressure limits ........................ 40 - 125 psi Supply water temperature limits ..................... 40 - 100 °F Maximum total dissolved solids (TDS) ............... 2000 ppm Maximum water hardness @ 6.
- REPAIR PARTS - Kenmore Reverse Osmosis Drinking Water System, Model No, 625.384700 33 !DRA , t ADAPTER 34 ! Bracket!Membrane Housing PUSH - IN FITrlNGS ] CO et 24 I 26 1/4" Tubing _ U 35 _10_ _ o-ring seals j3 I" I I 21 20 19 1 I I I I I .
Key NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 - REPAIR PARTS - Kenmore Reverse Osmosis Drinking Water System, Part Number 7205350 7207920 7185788 42-34702 71771.
- REMOTE LOCATION FOR REVERSE OSMOSIS SYSTEM - REMOTE RO INSTALLATION (storage tank not shown) Possible remote locations for the RO nearby the kitchen or bathroom sink include; (1) a basement area underneath the sink, and (2) an adjacent room or closet.
19.
OWNER'S MANUAL MODEL NO. 625,384700 The model number of your reverse osmosis system is found on the rating decal. This decal is on the top of the bracket.
Ein wichtiger Punkt beim Kauf des Geräts Kenmore 625.3847 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Kenmore 625.3847 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Kenmore 625.3847 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Kenmore 625.3847 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Kenmore 625.3847 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Kenmore 625.3847 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Kenmore 625.3847 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Kenmore 625.3847. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Kenmore 625.3847 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.