Benutzeranleitung / Produktwartung AD620 des Produzenten Analog Devices
Zur Seite of 16
CONNECTION DIAGRAM 8-Lead Plastic Mini-DIP (N), Cerdip (Q) and SOIC (R) Packages –IN R G –V S +IN R G +V S OUTPUT REF 1 2 3 4 8 7 6 5 AD620 TOP VIEW REV.
AD620–SPECIFICA TIONS (Typical @ +25 8 C, V S = 6 15 V, and R L = 2 k V , unless otherwise noted) AD620A AD620B AD620S 1 Model Conditions Min Typ Max Min Typ Max Min Typ Max Units GAIN G = 1 + (49.4 k/R G ) Gain Range 1 10,000 1 10,000 1 10,000 Gain Error 2 V OUT = ± 10 V G = 1 0.
AD620 AD620A AD620B AD620S 1 Model Conditions Min Typ Max Min Typ Max Min Typ Max Units DYNAMIC RESPONSE Small Signal –3 dB Bandwidth G = 1 1000 1000 1000 kHz G = 10 800 800 800 kHz G = 100 120 120 120 kHz G = 1000 12 12 12 kHz Slew Rate 0.75 1.2 0.
AD620 REV. E –4– NOTES 1 Stresses above those listed under Absolute Maximum Ratings may cause perma- nent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied.
AD620 REV. E –5– T ypical Characteristics (@ +25 8 C, V S = 6 15 V, R L = 2 k V , unless otherwise noted) INPUT OFFSET VOLTAGE – m V 20 30 40 50 –40 0 +40 +80 PERCENTAGE OF UNITS –80 SAMPLE SIZE = 360 10 0 Figure 3.
AD620–T ypical Characteristics FREQUENCY – Hz 1000 100 10 1 10 1000 100 CURRENT NOISE – fA/ ! Hz Figure 9. Current Noise Spectral Density vs. Frequency RTI NOISE – 2.0 m V/DIV TIME – 1 SEC/DIV Figure 10a. 0.1 Hz to 10 Hz RTI Voltage Noise (G = 1) RTI NOISE – 0.
AD620 REV. E –7– FREQUENCY – Hz PSR – dB 160 1M 80 40 1 60 0.1 140 100 120 100k 10k 1k 100 10 20 G = 1000 G = 100 G = 10 G = 1 180 Figure 14. Positive PSR vs. Frequency, RTI (G = 1–1000) FREQUENCY – Hz PSR – dB 160 1M 80 40 1 60 0.1 140 100 120 100k 10k 1k 100 10 20 180 G = 10 G = 100 G = 1 G = 1000 Figure 15.
AD620 REV. E –8– OUTPUT VOLTAGE SWING – Volts p-p LOAD RESISTANCE – V 30 0 0 10k 20 10 100 1k V S = 6 15V G = 10 Figure 20. Output Voltage Swing vs. Load Resistance .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... ...
AD620 REV. E –9– .... .... .... .... .... .... .... .... ........ .... .... .... .... .... .... .... .... ........ Figure 26. Small Signal Pulse Response, G = 100, R L = 2 k Ω , C L = 100 pF .... .... .... .... .... .... .... .... .... .... ....
AD620 REV. E –10– V B –V S A1 A2 A3 C2 R G R1 R2 GAIN SENSE GAIN SENSE R3 400 V 10k V 10k V I2 I1 10k V REF 10k V +IN – IN 20 m A 20 m A R4 400 V OUTPUT C1 Q2 Q1 Figure 33. Simplified Schematic of AD620 THEORY OF OPERATION The AD620 is a monolithic instrumentation amplifier based on a modification of the classic three op amp approach.
AD620 REV. E –11– Make vs. Buy: A Typical Bridge Application Error Budget The AD620 offers improved performance over “homebrew” three op amp IA designs, along with smaller size, fewer compo- nents and 10 × lower supply current.
AD620 REV. E –12– 3k V +5V DIGITAL DATA OUTPUT ADC REF IN AGND 20k V 10k V 20k V AD620B G=100 1.7mA 0.10mA 0.6mA MAX 499 V 3k V 3k V 3k V 2 1 8 3 7 6 5 4 1.
AD620 REV. E –13– Precision V-I Converter Th e AD620, along with an other op amp and tw o resistors, makes a precision current source (Figure 37). The op amp buffers the reference terminal to maintain good CMR. The output voltage V X of the AD620 appears across R1, which converts it to a curre nt.
AD620 REV. E –14– COMMON-MODE REJECTION Instrumentation amplifiers like the AD620 offer high CMR, which is a measure of the change in output voltage when both inputs are changed by equal amounts. These specifications are usually given for a full-range input voltage change and a speci- fied source imbalance.
AD620 REV. E –15– GROUND RETURNS FOR INPUT BIAS CURRENTS Input bias currents are those currents necessary to bias the input transistors of an amplifier.
AD620 REV. E –16– OUTLINE DIMENSIONS Dimensions shown in inches and (mm). Plastic DIP (N-8) Package 8 14 5 0.430 (10.92) 0.348 (8.84) 0.280 (7.11) 0.240 (6.10) PIN 1 SEATING PLANE 0.022 (0.558) 0.014 (0.356) 0.060 (1.52) 0.015 (0.38) 0.210 (5.33) MAX 0.
Ein wichtiger Punkt beim Kauf des Geräts Analog Devices AD620 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Analog Devices AD620 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Analog Devices AD620 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Analog Devices AD620 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Analog Devices AD620 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Analog Devices AD620 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Analog Devices AD620 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Analog Devices AD620. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Analog Devices AD620 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.