Gardtec 350+ 2897PDF GARDINER TECHNOLOGY Gar dtec 350+ Quic k Star t User Guide.
Intr oduction This Quick Start Guide is intended to help end users who are new to security systems in the da y to da y use of the system. W e recommend that this guide is used in conjunction with the end user manual that w as supplied with the control panel.
T ampers & P As Y our security system protects itself against tamper ing. In the e vent of an y control equipment, detectors or sounders being opened or cables being cut the internal and/or the e xter nal will sound. Dependant on the le v el of system you ha v e installed this ma y require an engineer call-out to reset the system.
P o wer LED The P ower LED giv es an indication of that the mains supply to the unit is good. It should be illuminated at all times e xcept when User Programming mode is being used.
T o P art Set the System Then retire to an unprotected area Note: Y our engineer ma y hav e programmed the P ar t Set e xit sounders as silent. If so a single beep will be giv en when the e xit time e xpires.
Resetting After An Alarm After an alar m all the LEDs will be flashing. Pressing No will displa y the cause of the alar m f or 3 seconds. F or example . System is Unset. Z 3 illuminated. All LEDs are flashing. Zone 3 was activ ated when system was set.
User Pr ogramming Mode T o enhance the flexibility of the Gardtec 350 control panel there are fiv e user programmab le options av ailable . When programming the user options the displa y is via the fiv e zone LEDs and the legend to the right of the LEDs is used (see illustration belo w).
TEST This option allows a Master User to test the system z ones and sounders. LOG This option allows a Master User to vie w the system Ev ent Log. CHIME One or more system zones ma y hav e been programmed as chime z ones b y your installation engineer .
The displa y will show . If you wish to Remo v e more zones return to * OR T o set the system with the Zone(s) you selected Remov ed Exit Wa i t After e xiting and securing the premises alwa ys wait until the e xit sounders hav e stopped bef ore leaving.
The displa y will show . The displa y will show . The displa y will show . When you ha ve finished testing the system press. This is T est Mode. Y ou ma y now ‘walk T est’ the system. Each time you activ ate a zone the inter nal sounder will sound and the corresponding LED will illuminate on the control panel.
Vie wing The Log With the system in Da y Mode (Unset). The displa y will show . The displa y will show . The displa y will show ..
The displa y will now sho w the last system e v ent and will v ar y dependant on what that e v ent was . Whilst using the Log Mode the No ke y is used to move to the pre vious ev ent and the Y es ke y is used to move to the ne xt ev ent.
T urning Chime On/Off Chime zones will ha v e been pre viously programmed b y your installation engineer . A Master le v el user ma y tur n the Chime function On or Off . Zones that are programmed as Chime z ones will giv e a low le vel ‘beep’ sequence when activated.
The displa y will show . The displa y will show . T o Escape back to Da y Mode. Pr ogramming User Codes Up to nine user codes ma y be programmed into the 350+ control panel, each user code has a predeter mined le v el of access.
The sequence f or programming User Codes is . Enter User Code Programming Mode Enter the User Number (1 to 9) you wish to progr am Enter the Code you require f or the User Re-Enter the Code you require f or the User Retur n to Da y Mode This is shown step b y step below .
The displa y will show . The displa y will show . The displa y will show ..
The displa y will show . The displa y will show . The displa y will show . Enter User Number (1 to 9) Note: T amper LED has rapid flash Enter New Code Note: T amper LED has slow flash.
The displa y will show . The displa y will show . T o Escape back to Da y Mode Note: T o delete a User Code enter 0000 as the New Code . User Number 1 is the main system code, theref ore it may only be changed and not deleted. Additional inf ormation is contained within the User Manual that was supplied with the Gardtec 350 Contr ol Panel.
Ein wichtiger Punkt beim Kauf des Geräts AmeriGlide GARDTEC 350+ (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie AmeriGlide GARDTEC 350+ noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für AmeriGlide GARDTEC 350+ - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von AmeriGlide GARDTEC 350+ reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über AmeriGlide GARDTEC 350+ erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon AmeriGlide GARDTEC 350+ besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von AmeriGlide GARDTEC 350+ verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit AmeriGlide GARDTEC 350+. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei AmeriGlide GARDTEC 350+ gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.