Propane Heater 20,000 BTU/HR Model PH20-30A With Automatic Gas Ignition Control Installation Operation Service.
EXHAUST GASES Do not operate heater in an enclosed area unless the exhaust gases are piped outside. Exhaust gases may contain carbon monoxide, a colorless and poisonous gas. FUEL USE This heater is designed for use w ith propane (LP gas) only .
Section One ____________________________________________________________ 3 Introduction and Descr iption ______________________________________.
This manual contains installation, operation, maintenance, and repair instruct ions for Model PH-20-30A Heaters manufactured by Hunter Manufacturing Company, Solon, Ohio.
1. Inspect the heater for damage that may hav e occurred during shipment.
LOCATION AND MOUNTING (cont .) 1. Mount the heater ho rizontally, as shown in figure 4. Choose a m ounting location that will enable mounting the heater on a level surface, with adequate room around the heater for removal and service. Check tha t the tilt switch is upright.
# $ % $% .
&' % $ % # .
(! " % )*" )+ #.
1. Locate and moun t the propane tank (gas bottle) aw ay f rom the engine and heater exhaust ports. The location should also p r otect the tank from accidental mechanical damage. 2. The propane tan k must be a gas bo ttle designed or modi fied for vapor takeoff only.
1. Refer to the wiring diagram in figure 7, locate the pow er and ground connections on your heater. The ground terminal is located one inch to the le f t of the f uel inlet. Connect this terminal to a good, clean chassis ground, using the wire size listed in Table 1.
(f igur e 7 ) Symbol Descript ion B1 Blower M otor ECM Electronic Co ntrol Module E1 Igniter L1 Solenoid Valve LED1 L.E.D. Assembly PS1 Pressure Sw itch S1 Tilt Switch S2 Over heat Thermos tat S3 Room Ther mostat (opti onal) S4 Comfort Control Thermo.
' Comfort Control Assembly Con trols an d In dic ato rs (figure 5) Table 2. Control and I ndicator Functions Name Function Main Switch Simple on/off sw itch.
'+ The Falco naire PH 20-30A is a M icroprocessor Base d Direct S park Ignition, the rmostatically controlle d heater. The cont rol utilizes a microp rocessor to continu ally and safely monitor, anal yz e and control the pro per operation of the gas burner.
" Cab or Cre w A rea 1. Flip Main switch to ON 2. Rota te Co mfort Control knob approximately 75% of full travel clock w ise. 3. W he n temperature in t he heated area is satisfactory rotate Comfo rt Control k n o b counter clock wise until a "click" is felt in t he knob.
)( ## The PH20-30A has built in diagnostic capabilities. W hen the microprocessor-based control detects a fault, it displays an error code by flashing t he red LED.
'" The diagnostic features of the ECS w ill cover most problems that you may have with your heater. Table 5 Troubleshooting chart addresses some other problems that may arise TA BLE 5.
! , * The follow ing service p rocedures, if performed as indicated, w ill help ensure prope r operation and extend the li f e of your hea ter.
* Genera l This section lists and illustrates the major parts o f your model PH20-30A Hunter heater. In g eneral, attaching parts such as s crews, nuts and loc k washers have not been listed or illustrated since their application is obvious.
(&' " 1 2 3 4 5 6 7 8 9 10 11 12 1 3 Index # Part # Description 1 49131 Crossbar 2 49196 Covers 3 493151 Top Cover 4 49828 Termi.
," , +% 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Index # Part # Description 1 5.
) ! % + 1 2 3 4 5 6 7 8 9 Index # Part # Description 1 10599-07 Inlet Air Duct 2 50875 Cover 3 51567 Combustion Blow er W heel 4 50576 Co.
% % ( 1 2 Index # Part # Description 1 52944-6 Remote Cable 6ft 2 52621 Comfort Control Asse mbly complete * L.
& 1 2 2- 1 / 2 " Duct Opening 3 Index # Part # Description 1 52944-10 10 Foot Lon g Remote.
% ' % Plug Thermostat In Here PH20-30A Heater (rear view ) Calibrated Thermos tat P/N51643 Plug the remote thermostat into the rear of the heater using the spade connectors supplied.
& " "' The Ph20-30A comes w it h a addi tional power lead on the bac k of the Comfort Control to attach a remo te or external dia gnostic light.
Ein wichtiger Punkt beim Kauf des Geräts Hunter Fan PH20-30A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Hunter Fan PH20-30A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Hunter Fan PH20-30A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Hunter Fan PH20-30A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Hunter Fan PH20-30A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Hunter Fan PH20-30A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Hunter Fan PH20-30A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Hunter Fan PH20-30A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Hunter Fan PH20-30A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.