Benutzeranleitung / Produktwartung 53171 des Produzenten Hunter Fan
Zur Seite of 17
www .HunterF an.com 1.888.830.1326 PA G E 7 PA G E 13 PA G E 10 PA G E 5 PA G E 6 30 inches 7 feet PA G E 2 What to Expect with Y our Installation Ceiling Br acket Ladder PA G E 3 T ools Needed Wiring.
www .HunterF an.com 1.888.830.1326 M0094-01 • 02/19/14 • © Hunter F an Company 1.888.830.1326 1.888.830.1326 What t o Expec t with Y our Installation Know your wiring If you are unfamiliar with wiring, use a qualied electrician. Y ou may need a friend to help you.
www .HunterF an.com 1.888.830.1326 T ools Needed Ladder Po wer Drill (optional) 9/64” Drill Bit (optional) Screwdrivers Pliers Wire Strippers If mounting to a support structure, you will also need these tools .
www .HunterF an.com 1.888.830.1326 If you ha ve an angled ceiling: 1. Y ou will need a longer downrod (sold separately) . 2. If your ceiling angle is greater than 34°, y ou will also need an Angled Mounting Kit (sold separately) .
www .HunterF an.com 1.888.830.1326 C eiling Bracket OFF Make sure all four (4) bumpers are still attached . F or angled ceilings, point opening toward peak.
www .HunterF an.com 1.888.830.1326 C eiling Bracket (c ontinued) Prepar ation 1.888.830.1326 www .HunterF an.com D I S C A R D K E E P ! Remove the shipping blocks from the motor . Sav e the screws . They will be needed for blade iron installation. Note: Some fans will hav e a shipping ring instead of shipping blocks.
www .HunterF an.com 1.888.830.1326 7 M0094-01 • 02/19/14 • © Hunter F an Company Downrod Slid e Slid e 1 2 3 4 5 6 7 8 9 10 Sold Separately Included Longer Downrod for angled ceilings or ceilings.
www .HunterF an.com 1.888.830.1326 8 M0094-01 • 02/19/14 • © Hunter F an Company KEEP! 8” 3/8” C U T & S T R I P (not to scale) Remove the pr e-installed setscrew so that the downrod can be inserted. Hand tighten the downrod (at least 4-5 full turns) until it stops.
www .HunterF an.com 1.888.830.1326 Downrod (c ontinued) DO NO T PICK THE F AN UP BY THE CANOPY OR WIRES. Place the downrod ball into the slot in the ceiling bracket. Put the wires and do wnrod through the canopy . Let the canop y sit loosely on top of the fan.
www .HunterF an.com 1.888.830.1326 Wiring F R O M F A N F R O M C E I L I N G B R A C K E T F R O M F A N Using an orange wire connector from the hardware bag , connect the 3 grounding wires (green, green/ yellow stripe , or bare copper) coming from the ceiling , downrod, and hanging bracket.
www .HunterF an.com 1.888.830.1326 Canop y Lift the canopy into place so that the screw holes are aligned . Position the canop y so that, when lifted into place , the canopy ts into the hanging bracket as shown. Screw Holes Insert the two canopy screws found in the hardwar e bag.
www .HunterF an.com 1.888.830.1326 Blades Y our blades are shielded with Dust Armor® which is a nanotechnology coating that repels dust. F or cleaning the fan, use soft brushes or cloths to prevent scratching . Cleaning agents ma y damage the nishes.
www .HunterF an.com 1.888.830.1326 F eed the wire plug through the center hole of the upper switch housing , then wrap keyhole slots around the screws and twist counterclockwise. Screw two (2) housing assembly screws from the hardware bag halfwa y into the motor housing .
www .HunterF an.com 1.888.830.1326 14 M0094-01 • 02/19/14 • © Hunter F an Company Light Kit Partially install two of the switch housing screws found in the bag . Connect the plugs from the upper and lower switch housings. Make sure to line up the colored markings on the connectors.
www .HunterF an.com 1.888.830.1326 Light Kit (c ontinued) See next page for fan opera tion instruc tions. C ONGRA TULA TIONS! Y OU’RE DONE! See next page for fan opera tion instruc tions. Connect the appropriate pull chain pendant to each of the short chains coming from the nial and nial cap .
www .HunterF an.com 1.888.830.1326 Maintenanc e & Cleaning ON T urn P ower Changing the direction of air ow - move the reverse switch to the opposite position. Cleaning the fan - use soft brushes or cloths to prevent scratching . Cleaning products may damage the nishes.
www .HunterF an.com 1.888.830.1326 17 M0094-01 • 02/19/14 • © Hunter F an Company T roubleshooting Exc essive wobbling • Tighten all of the blade and blade iron screws until they are snug . • Use the provided balancing kit and instruc tions to balance the fan.
Ein wichtiger Punkt beim Kauf des Geräts Hunter Fan 53171 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Hunter Fan 53171 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Hunter Fan 53171 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Hunter Fan 53171 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Hunter Fan 53171 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Hunter Fan 53171 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Hunter Fan 53171 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Hunter Fan 53171. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Hunter Fan 53171 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.