Benutzeranleitung / Produktwartung 43168 des Produzenten Hunter Fan
Zur Seite of 21
1 Model 43168 Owners Manual HEA T PUMP PROGRAMMABLE THERMOST A T PM COOL TEM P 3 SA Form 44014-01 r010408.
2 3 Congratulations! Thank you for choosing a Climate T echnology Corporation (CTC) programmable thermostat. Y our new CTC thermostat will provide years of reliable service and year-round energy savings. Please read this manual before beginning installation and save this booklet for complete operation instructions.
4 5 1.This thermostat is designed to work on the following systems: • Single-Stage Heat Pump • Mulit-stage Heat Pump (up to 2 heating and 2 cooling) 2.T emperature Range This thermostat can be set between 45°F and 95°F (7°C and 35°C).However , it will display room temperatures from 30°F to 99°F (0°C and 37°C).
6 7 Wire Labeling • CAUTION! TURN OFF POWER TO THE HEA T PUMP SYSTEM BEFORE YOU A TTEMPT TO ACCESS THE THERMOST A T’S WIRING. • IMPORT ANT! BEFORE DISCONNECTING ANY WIRES FROM THE EXISTING THERMOST A T , APPL Y THE PROVIDED SELF-ADHESIVE LABELS TO THE WIRES.
8 9 Mount Wallplate • Remove the wallplate from the thermostat by pressing the release tab on the bottom of the thermostat. See Figure 2. Figure 2 • Positionwallplateonwall andpullexisting wiresthroughthelarge opening,thenlevelfor appearance.
10 11 ON O N 1 2 HE HG F C Connect Wires and Mount Thermostat to W allplate • Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate. See Figure 4. Ignore any wires which may be present, but which were not connected to the old thermostat.
12 13 THERMOST A T CONTROLS • Open the thermostat’s front cover . See Figure 6. Figure 6 • Insertthetabsontopofthethermostatbodyintotheslotsatthetopofthewallplate.Pressthebottomof the thermostat body into the snap on the bottom of the wallplate.
14 15 system off cool heat fan auto refresh on reset hold/rtrn em heat sys em aux lter program day/time A B C D E I J K Switches and Buttons Switches and Buttons A LCD Readout - displays indoor temperature, set temperature, and information about the heat pump system’s operation and status.
16 17 The default for this thermostat setting is in a 12 hour format. Y ou can change the format to 24 hour format by pressing D a y /T i m e and then P r o g r a m . The AM/PM indicator will be off when the thermostat is in 24 hour mode. Settingdayandtime: 1.
18 19 This thermostat gives you the ability to program up to 4 custom temperature settings per day or utilize pre-programmed settings. For manual operation instructions, see pages 21-23. T o utilize the pre-programmed settings, see pages 24-25. T o create custom programs, see pages 26-29.
20 21 1. MANUAL OPERA TION Many people prefer to operate their thermostats manually , adjusting settings as needed. Y ou can either temporarily override the settings for the current program, or permanently override all settings and adjust temperatures manually .
22 23 MANUAL OPERA TION, CONT . Ifyouwanttopermanentlyoverrideallsettingsandadjustthethermostatmanually: 1. Press H o l D /r e T U r n until the Hold icon appears. 2. Press and hold U P or D o w n for one second to enter Manual Override mode.
24 25 2. DEF AUL T PROGRAMS ThisthermostatmeetsENERGYST ARguidelinesforenergyefciency .Byusingthepre- programmed settings, this thermostat can save you money by optimizing energy usage in heating and cooling.
26 27 system off cool heat hold/rtrn em heat program Methods of Operation (cont.) AM PM H o l D /r e T U r n P r o g r a m U P and D o w n buttons s y s T e m switch AM/PM indicator 3. CREA TING CUSTOM PROGRAMS NOTES: • Programtimescanbesetin10minuteincrements.
28 29 Methods of Operation (cont.) system off cool heat em heat program AM HE AT PM COOL 4 3 2 1 M T W TH F SA SU 3. Press U P or D o w n to change the hour . Press P r o g r a m to save the hour and adjust the minute setting. 4. Press U P or D o w n to change the minute.
30 31 1. INDIGLO ® night-light - will backlight the display for easy viewing in the dark. Press any button to illuminate the light. 2. Filterchangeindicator-willashafter400hoursofsystemuseasaremindertocheckor changeyourlter .
32 33 6. Error mode – if the thermostat is unable to control your system due to an unexpected problem,thethermostatwillenterErrorMode.Inthiscondition,thethermostatashes“E1”, “E2”, or “E3” on the LCD display , and shuts off your system.
34 35 1. T emperature Range 2. Compressor Protection After the system stops running, there will be a 3.5 minute delay before it can be restarted to prevent compressor damage due to rapid cycling. 3. Resetting the unit T o restore the thermostat to the original factory settings, press the reset button with a paperclip.
36 37 Setting Options ThefollowingOptionsareavailableonyourthermostat: 1. 1st stage span - The factory setting for Stage 1 heating and cooling is 1, meaning that your thermostat will cycle at 1°F (0.5°C) above and below the set temperature in Stage 1.
38 39 TROUBLESHOOTING Problem Solution 1. Check wiring connections. A Common (C) wire is required for operation. 2. Press and hold the Reset button for two seconds with the tip of a paper clip. LCD Display is blank Auto/Fan does not turn on in Heat Mode 1.
40 41 WIRING DIAGRAM.
Ein wichtiger Punkt beim Kauf des Geräts Hunter Fan 43168 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Hunter Fan 43168 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Hunter Fan 43168 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Hunter Fan 43168 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Hunter Fan 43168 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Hunter Fan 43168 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Hunter Fan 43168 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Hunter Fan 43168. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Hunter Fan 43168 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.