OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL SOLAR WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL “SLN”.
2 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203) 378-2659 FAX: (203) 378-3593 INTERNET: http://www.hubbellheaters.com/ -- IMPORTANT -- Always reference the f ull model num ber and serial number when calling the factory. WARNING / CAUTION 1.
3 TABLE OF C ONTENTS SECTION TITLE PAG E # I GENERAL DESCRI P TION AND CONSTRUCTI ON 5 I I INSTAL LATI ON 8 III S C H E D U LE D M A IN TE NANC E AND OPERATION 11 I V TROUBL ES HOOTING 13 V SERVICI NG.
4.
5 SECTION I - GENERAL DESCRIPTION AND CONST RUCTION GENERAL DESCRIPTION This book describes a packaged solar water heater that is a stationary , self-contained unit. The complete assembly on a standard unit consists of the storage tank, immersion heating coil, and an ASME rated combination temperat ure and pressure safety relief valve.
6 OUTER SHELL AND INSULATION The tank is encapsulated in 2-inch thick polyurethane foam insulation. The insulation is protected by a high impact non-corroding colorized composite protective jacket.
7 Temperature Hig h Limit S witch As a safety device, either a surface mounted hig h temperature cut-off switch with manual reset, factory set at 190° F, or an immersion high temperature cut-off switch with manual reset, factory set at 180° F, may be provided.
8 SECTION II – INSTALLATION WARNING / CAUTION DO NOT TURN ON THE SOL AR WATER SUPPL Y to this equipment until heate r is completely filled with water and all air has be en rele ased. If the heate r is NOT filled with water when the power is turned on, damage to the heating coil may result.
9 PIP ING INSTALLATION NOTE: The most effect ive means for preventing deteriorat ion from accelerated corrosi on due to galva nic and stray curre nt is the installation of dielectric fittings/unions. The installation of these fittings is the responsibility of the installing contractor.
10 Outlet to floor drain Install into provided tapping Manual Release Lev e r Temperature Probe Temperature and Pressure Relief Valve 5. I nstall a relief valve overflow pipe to a nearby floor drain. CAUTION: No valve of any type should be installed between the relief valve and tank or in the drain line.
11 SECTION III - SCHEDULED MAINTE NANCE AND OPERATION WARNING / CAUTION Before performing any maintenance procedure, make certain solar water and electric supply is OFF and cannot accidentally be turned on. MAINTENANCE AND OPERATION The water heater is automatic in its operation.
12 ANNUAL INSPECTION 1. Flush tank as follows a. Shut off power supply . b. Close valve on hot water outlet piping. c. Open valve on drain piping. d. Cold water inlet line pressure will be strong enough to flush sediment from the bottom of the tank out through the drain.
13 SECTION IV – TROUBLESHOOTING SOLAR WATER SY STEM Symptom Probable Cause Corrective Action / Remedy T u b es a r e f o u l e d . C l e a n t u b e s p er S e c t i o n III, a nnual scheduled maintenance. Gradual loss of heating capacity. Excess silt in bottom of tank.
14 BACK -UP ELECTRCIAL HEATER SYSTEM (if supplied) Symptom Probable Cause Corrective Action / Remedy Circuit breaker tripped at source. Reset circuit breaker. High limit switch tr ipped. Reset hig h limit switch. Loose wires. Tighten wires. Torque screws per torque chart included in Section VI .
15 SECTION V - SERVICING & REPLACEMENT OF PARTS WARNING / CAUTION Before servicing or replacing any part make sure to turn the power supply switch to the OF F position. RELIEF VALVE 1. Disconnect power from unit. 2. Shut off incoming cold and solar water supply .
16 HEATING COIL 1. Disconnect power from unit. 2. Shut off incoming cold and solar water supply . 3. Attach hose to drain connection. 4. Lift manual release lever on relief valve to let air into sy stem or break union on outgoing water line. 5. Drain water from tank.
17 HEATING ELEMENT (if supplie d) 1. Disconnect power from unit. 2. Shut off incoming water supply . 3. Attach hose to drain connection. 4. Lift manual release lever on relief valve to let air into sy stem or break union on outgoing water line. 5. Drain water from tank.
18 2 L 1 L 2 L 3 L 1 L 2 Single Element Operation 3 Ø O p e n D e l t a W i r i n g f o r S i m u l t a n e o u s O p e r a t i o n 4 3 2 1 1 2 1 2 3 4 1 1 3 4 2 1 2.
19 L 1 L 2 L 1 L 2 I nterlocked for Non-Simultaneous Operation Non-I nterlocked for Simultaneous Operation 1 1 1 1 2 2 2 2 3 3 4 4 4 4 1 1 2 2.
20 SURFACE MOUNTED THERMOS TAT (if sup plied) 1. Disconnect power from unit. 2. Remove access cover and locate t hermostat. 3. Disconnect the two (2) or three (3) 14 gauge wires and jumpers, as required. Control Wires 4. Remove two (2) mounting screws and disconnect fr om high limit cut- off, if re quired.
21 IMMERSION THERMOSTAT ( if supplied) 1. Disconnect power from unit. 2. Remove access cover and locate t hermostat. 3. Remove high limit c over screw and cover. Cover Cover Screw 4. Disconnect the two (2) or three (3) 14 gauge wires, as required. Wires Capillary Tube 5.
22 Model SLN – Coil Curves.
Ein wichtiger Punkt beim Kauf des Geräts Hubbell Electric Heater Company SLN (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Hubbell Electric Heater Company SLN noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Hubbell Electric Heater Company SLN - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Hubbell Electric Heater Company SLN reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Hubbell Electric Heater Company SLN erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Hubbell Electric Heater Company SLN besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Hubbell Electric Heater Company SLN verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Hubbell Electric Heater Company SLN. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Hubbell Electric Heater Company SLN gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.