Hoshizaki “A Superior Degree of Reliability” www .hoshizaki.com Models KM-501MAH KM-501MWH KM-501MRH Modular Crescent Cuber Hoshizaki America, Inc.
2 IMPOR T ANT Only qualified ser vice technicians should attempt to install, ser vice or maintain this icemaker . No installation, ser vice or maintenance should be under taken until the technician has thoroughly read this Instruction Manual.
3 • Please re vie w this manual. It should be read carefully bef ore the icemak er is installed and operated. Only qualified ser vice technicians should install, ser vice and maintain the icemaker . This manual should be made a v ailab le to the technician prior to installation, maintenance or ser vice.
4 I. Specifications A. Nameplate Rating 1. KM-501MAH (air-cooled) See the nameplate f or electrical and refr igeration specifications . This nameplate is located on the upper right hand side of rear panel.
5 2. KM-501MWH (water-cooled) See the nameplate f or electrical and refr igeration specifications . This nameplate is located on the upper right hand side of rear panel.
6 3. KM-501MRH (remote air-cooled) See the nameplate f or electrical and refr igeration specifications . This nameplate is located on the upper right hand side of rear panel.
7 B. Dimensions / Connections 1. KM-501MAH Unit: inches (mm.).
8 2. KM-501MWH Unit: inches (mm.).
9 3. KM-501MRH Unit: inches (mm.).
10 II. Installation and Operating Instructions A. Checks Bef ore Installation IMPOR T ANT 1. Remov e shipping car ton, tape(s) and packing. If packing material is left in the icemaker , it will not work proper ly . 2. Ensure all components, f asteners and thumbscre ws are securely in place .
11 Icemaker Bin Bolts Mounting Brackets C. Location W ARNING This icemaker is not intended f or outdoor use. Nor mal operating ambient temperature should be within +45°F to +100°F; Nor mal operating water temperature should be within +45°F to +90°F .
12 E. Electrical Connection W ARNING 1. Electr ical connection must be made in accordance with the instructions on the "W ARNING" tag, provided with the pig tail leads in the junction bo x. 2. This icemaker requires a ground that meets the national and local electrical code requirements.
13 F . Installation of Remote Condenser Unit 1. Checks Bef ore Installation 1) Unpack and remo ve shipping car ton, tape(s) and packing. 2) Check that the refrigerant lines do not rub or touch lines or other surf aces , and that the f an b lade mov es freely .
14 3. Setup 1) Secure the legs to the condenser unit with eight M8 x 16 mm he xagon bolts and M8 nuts as sho wn in the illustration. See Fig. 5. Note: Locate the legs symmetrically . 2) The legs hav e eight mounting holes. Secure the legs with eight bolts (not included).
15 4. Electrical Connection W ARNING This remote condenser unit requires a ground that meets the national and local electrical code requirements. T o pre v ent possib le electrical shock to individuals or e xtensiv e damage to equipment, install a proper ground wire to the condenser unit.
16 5. Stacking Condenser Unit 1) Secure the low er condenser unit to the legs with eight bolts (not included). 2) Attach the upper condenser unit on the top of the low er . 3) Secure the upper condenser unit with the f our scre ws provided. 4) Install refrigerant lines, and mak e electrical connection f or each f an motor as shown in Items 3.
17 G. W ater Suppl y and Drain Connections See Fig. 9 CA UTION T o prev ent damage to the pump assembly , do not operate the icemak er when the water supply is OFF , or if the pressure is below 10 PSIG. Do not run the icemaker until the proper w ater pressure is reached.
18 KM-501MWH KM-501MAH KM-501MRH Fig. 9.
19 H. Final Checklist 1) Is the icemaker le v el? 2) Is the icemaker in a site where the ambient temper ature is within +45°F to +100°F and the water temper ature within +45°F to +90°F all y ear a.
20 I. Star tup CA UTION 1. All par ts are f actor y-adjusted. Improper adjustments ma y result in f ailure. 2. If the unit is tur ned off, w ait for at least 3 minutes bef ore restar ting the icemaker to pre v ent damage to the compressor . 3. Do not operate the unit in the "W ASH" position without water in the water tank.
21 J . Preparing the Icemaker for Long Stora ge CA UTION When shutting off the icemaker f or an e xtended time, dr ain out all water from the water line and remo v e the ice from the storage bin.
22 3. Follow the instructions below to drain the potab le water tank. 1) T ur n off the power supply . 2) Mov e the control switch on the control bo x to the "OFF" position. 3) Remov e the base cov er . 4) Remov e one end of the pump tubing and drain the water tank.
23 III. Cleaning and Maintenance Instructions IMPOR T ANT Ensure all components, f asteners and thumbscrews are securely in place after any maintenance or cleaning is done to the equipment. A. Cleaning Instructions W ARNING 1. HOSHIZAKI recommends cleaning this unit at least once a year .
24 1. Cleaning Procedure 1) Dilute appro ximately 16 fl. oz. of recommended cleaner Hoshizaki "Scale A wa y" or "LIME-A-W A Y ," (Economics Laborator y , Inc.) with 3 gal. of water . 2) Remov e all ice from the ev aporator and the storage bin.
25 2. Sanitizing Procedure - Follo wing Cleaning Procedure 1) Dilute a 5.25% sodium h ypochlorite solution with water (Add 1.5 fl. oz. of sanitizer to 3 gal. of water). 2) Remov e the insulation panel. 3) P our the sanitizing solution into the water tank.
26 B. Maintenance IMPOR T ANT This icemaker m ust be maintained individually , ref erring to the instr uction manual and labels pro vided with the icemak er . 1. Stainless Steel Exter ior T o prev ent corrosion, wipe the exterior occasionally with a clean and soft cloth.
27 HOSHIZAKI AMERICA, INC. 618 Hwy . 74 S., Peachtree City , GA 30269 USA TEL (770) 487-2331 F AX (770) 487-3360 www .hoshizaki.com 91A1MN10A.
Ein wichtiger Punkt beim Kauf des Geräts Hoshizaki KM-501MWH (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Hoshizaki KM-501MWH noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Hoshizaki KM-501MWH - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Hoshizaki KM-501MWH reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Hoshizaki KM-501MWH erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Hoshizaki KM-501MWH besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Hoshizaki KM-501MWH verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Hoshizaki KM-501MWH. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Hoshizaki KM-501MWH gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.