Benutzeranleitung / Produktwartung VISTA-50P des Produzenten Honeywell
Zur Seite of 72
N5943-6V 2 5/04 R ev A $ $ ' ' ( ( 0 0 & & 2 2 9 9 , , 6 6 7 7 $ $ 6 6 ( ( 5 5 , , ( ( 6 6 9 9 , , 6 6 7 7 $ $ 3 3 9 9.
– 2 –.
– 3 – TABLE OF CONTENTS SYSTEM OV ERVIE W ....................................5 General .......................................................5 A Partit ioned S ystem ..................................5 Zones .....................................
– 4 – SPEED K EY (MACRO S) .............................. 38 General Inf ormation .................................. 38 Defining .................................................... 38 Executing .................................................. 39 ACCESS DOO R CONTROL .
– 5 – System Overvi ew General Your Hon eywe ll securi ty sy stem con sists of a main c ontrol p anel, at least one keypa d, and variou s sensor s strate gically posi tione d throughout the premis es. Th e sy stem offe rs you thr ee for ms of prot ecti on: bur gla ry, f ire and emerg ency .
– 6 – System Overvi ew (cont’d) Fire Protection The fir e pr ot ection por tio n of y our secur ity syst em ( if used ) i s alw ays on and will sound an alarm if a f ire condi tion is d etected.
– 7 – System Overview (cont ’ d) Speed Key (M acros) The sy stem can s tore a st ring of up to 32 k eystr oke s, whic h can be ac tivat ed anytime by simp ly pr essi ng th e “A, B, C, or D” keys.
– 8 – System Overview (cont ’ d) Master Keyp ad Operat ion A "Mast er" k eypad is one on wh ich the statu s of al l 8 p artition s i s displ ayed simultane ously. A user ca n get more infor mation about a cer tain parti tion by simply en terin g [ ✳ ] + the desi red partit ion number (1-8 ).
– 9 – About The Keypads General IMPORTANT: If th e keypad beeps ra pidl y upon ent erin g the premises, it ind icates t hat a n alarm h as o ccurred d uring y our absence. LEAVE I MMEDI ATELY and CONT ACT TH E PO LICE from a safe locat ion nearby .
– 10 – Functions Of The Keypad 1 OFF 4 MAX 7 INSTANT READY 2 AWAY 5 TEST 8 CODE 0 3 STAY 6 BYPASS # ARMED READY 6160-00-002-V1 9 CHIME A B C D SPEAKER LCD DISPLAY FUNCTION KEYS LEDS IMPORTANT!: When using the keypad to enter codes and commands, sequential key depressions must be made within 3 seconds of one another.
– 11 – Functions Of The Keypad (cont ’ d) ALPHA DISPLAY WINDO W: A 2-line, 32-character Liquid Cryst al Display (LCD) . Display s pr otec tion p oint identif icati on and system statu s, messa ges, and user instruc tions.
– 12 – Functions Of The Keypad (cont ’ d) 9 CHIME : Tu rns on & off the C HIME mode. When on, any entry th rou gh a protecte d delay or perimete r zone while the system is di sarmed will cause a t one to sound at t h e Keypad(s).
– 13 – Entry/Exit Delays General Information Your sy stem has in stal ler-p rogrammed tim e delays, known as exit d elay an d entry d elay . Wh enev er y ou ar m your sys tem , exit delay gives y ou time to leave th roug h the d esig nated exit d oor w ith out s etting off an alarm.
– 14 – Security Codes & Authority Levels General Information At the tim e of install ati on, you w ere assign ed an authori ty lev el and a personal four-digit security code, known only to you and yours. The security code must be entered when a rming and dis arming the system.
– 15 – Security Codes & Authority Levels (cont ’ d) Authority Levels Author ity l eve ls def ine th e syst em f unc tions a p artic ular u ser can perf orm. Depend ing on the au thor ity a ssign ed to y ou, t here ar e cer tain sy stem func tions y ou may be pro hibited from perf ormin g.
– 16 – Security Codes & Authority Levels (cont ’ d) General Rules on Authority Levels and Changes • A user m ay not d elete or chan ge the u ser c ode of t he SA ME or HI GHER author ity th an which he is as signed . • A user may only ADD users to a LOWER autho rity level.
– 17 – Security Codes & Authority Levels (cont ’ d) To Add a User IMPORTANT: Tem por ary user s shou ld no t be sh ow n how to us e any sy st em func tion th ey do no t need to kn ow ( e.g. by pa ssing prot ection zon es). CODE 1. Enter M a ster or Manager code and press the 8 key.
– 18 – Security Codes & Authority Levels (cont ’ d) MULTI-ACCESS ? 0 = NO , 1 = YES If you as a user have access to other partitions, the keypad wi l l prompt for abil i ty of this ne w user to access (GOTO) those partitio ns. Press 0 (NO) or 1 (YES).
– 19 – Security Codes & Authority Levels (cont ’ d) To Change a User ’ s Code CODE 1. Enter M a ster or Manager code and press the 8 key + user number to be changed.
– 20 – Accessing Other Partitions To Access Another P artition Eac h keypad is assig ned a default partit ion f or dis pla y purpose s, and w ill sho w onl y that partit ion ’ s inform ati on.
– 21 – Accessing Other Partitions (cont ’ d) ARM P 1 2 3 4 5 6 7 8 HIT 0-8 X X X - - X - - The pr ompt disp lay s all the par ti tions. Th e user may only arm /dis arm th e part itions they are assigned acc ess t o. To selec t the pa rtitio n(s) tha t are to be armed , enter th e desir ed num ber 1- 8.
– 22 – Accessing Other Partitions (cont ’ d) Master Keyp ad Operation A "Master " keypad is o ne tha t r eflec ts th e sta tus of the en tire sy stem (Partiti ons 1- 8) on its d isplay .
– 23 – Accessing Other Partitions (cont ’ d) Addition al zon e faults w ill be di splay ed one at a time . To disp lay a n ew partition ’ s s tatu s, pres s ✴ + [ Partiti on No.
– 24 – Accessing Other Partitions (cont ’ d) c. Arming th e last p artition p rogrammed to arm th e lobby will automatic ally attempt to arm th e lobby.
– 25 – Checking For Open Zones Using the ✳ READY Key Befor e arming your syst em , all prot ected door s, wi ndow s and oth er pr otec tion zones m ust b e clo sed or b ypa ssed ( se e BY PASSI NG secti on) . O ther wise th e keypa d will dis play a "Not Ready" messa ge.
– 26 – Displaying All Zone Descriptors Using the ✳ READY Key The Alp ha Key pads can also di splay all th e zon e descript ors th at ar e programmed in your syst em. The abbrev iated in struction s for the READY key will appear fir st, f ollowed by the z on e descript ors.
– 27 – Bypassing Protection Zone s Using the 6 BYPASS Key This key is used whe n you want to arm your s ystem with o ne or more zones intentiona lly unprotected. Bypass ed zones are unprotected and will not ca u se an alarm wh en viol ated while y our sy stem i s armed.
– 28 – Bypassing Protection Zone s (cont ’ d) Quick Bypass Your system all ows y ou to ea sily byp ass all open ( faulted ) zon es w ithou t having to enter zone numbers indivi dual ly. Note: All by pass es are r em oved wh en an O FF seq uenc e (sec uri ty code p lus OFF) is pe rformed.
– 29 – Arming Perimeter Only (With Entry Delay ON) Using the 3 STAY key Use thi s key w hen y ou are st aying home, bu t mig ht exp ect som eon e to us e the en tran ce door la ter.
– 30 – Arming Perimeter Only (With Entr y Delay OFF) Using the 7 INSTANT Key Impor tant: If you are using a Symphony (Advance d User Interfa ce), NIGHT mode is t he same as INSTANT. Use th is key w hen you are s taying hom e and do no t ex pect any one to use the entranc e d oor.
– 31 – Arming All Protection (With Ent ry Delay ON) Using the 2 AWAY Key Use th is key when no one w ill be stay ing on th e pr emis es. When arm ed in A WAY mode, the sy stem will soun d an alarm if a p rotect ed door or w indow is open ed, or if any m ovem ent i s d ete cted in sid e th e pr emise s.
– 32 – Arming All Protection (With Entr y Delay OFF) Using the 4 MAXIMUM Key Use this k ey wh en th e pr emises w ill be vacan t for ext ended p eriods of tim e such as v ac ation s, e tc., or w hen n o one w ill be m ovi ng th rough pro tec ted interior are as.
– 33 – Disarming And Silencing Al arms Using the 1 OFF Key The OFF key is u sed to di sarm th e sy stem an d to silenc e al arm and troubl e sounds. See "SUMMAR Y OF AUDIBLE NOTIFICATION" section for information which w ill help y ou to di stingu ish between FIRE an d BURGLARY alarm sounds.
– 34 – Using The Keyswitch General Your syst em may be equipped with a keyswit ch for use when a rm ing and disarmi ng a partitio n. A red and gree n light on the keys wi tch plate i ndicate the st atus of y our sy stem as f ollow s: Green Light: Ligh ts w hen the sy st em is disarmed and ready to be armed ( no op en z one s).
– 35 – Chime Mode Using the 9 Key Your system can be set t o aler t you to th e op ening of a d oor or win d ow wh ile it is di sarm ed by using C HIME mod e. Wh en ac tiva ted, th ree tone s wil l soun d at the K eyp ad w hen ever a p rotec ted p eri met er do or or wind ow is op ened, and the N ot R eady m essag e will b e di splay ed.
– 36 – Viewing Alarm Company Messages General Information User s of th e syst em ma y p eriodica lly r eceiv e m essag es on th eir d ispl ay screen s fr om th eir m onit orin g agen cy or insta ll er. Wh en a m essag e i s waitin g to be vi ew ed, th e m essag e show n b elow w ill appe ar.
– 37 – Panic Keys (For Manually Activat ing Silent And/Or Audible Alarm s) Using Panic Keys Your syst em may h ave b een prog ram med to us e sp ecia l key c ombin ati ons t o manually ac tivate panic funct ions. The funct ions that might be programmed are Silent Emer gency, Audible Emergency, Personal Emerge ncy, and Fire.
– 38 – Speed Key (Macros) General Information The “ D ” key c an be use d to act iva te a stri ng of co mmands up to 16 keys trokes each. The se comm and s a re kn own a s a m acro and are st or ed in the sy stem ’ s memory.
– 39 – Speed Key (Macros) (cont ’ d) Executing To acti vate a Speed Key, press and hold down the [D] key for 2 seconds. If a user c ode is r equir ed f or any part of the Sp eed Ke y sequ ence , th e follow ing prompt app ear s. Otherwis e, the Speed Key s equenc e automat ically beg ins.
– 40 – Access Door Control General Information Yo ur system m ay be set u p su ch t hat a lo cked a ccess door (s uch as in a lob by) can be unloc ked m omenta rily or for a spec ific p eriod of time, using a keypad command. Ask your installer if this ha s been don e in our sy stem.
– 41 – Using #70 Relay Menu Mode General Information Your syste m may be set up so that certai n lights or other devices can be turned on or off by using th e #70 command from ei ther a keyp ad or a telephon e keypad (if 42 85 or 4286 VI P mod ule i s used) .
– 42 – Using Schedules Delaying the Closing Time Your sy ste m ’ s programmed schedules may automatically arm the system at a predet ermi ned time . In the event a us er mu st st ay on the pr emi ses l ater than usual, users with maste r or manager authority levels can manually dela y the automati c arming (closing) time up to 2 hours.
– 43 – Using Schedules (cont ’ d) Programming Temporary S chedules Te mporary sche dules o n ly aff ect the partit ion fro m which it is ente red . Temporary schedul es can be reu sed at later dat es simply by scrolling (by pressin g #) to the D AY S? promp t (descri bed be low) an d activa ting the approp ria te day s.
– 44 – Using Schedules (cont ’ d) DAYS ? MT WTFSS HIT 0-7 X X This is the p romp t that ac tually activa tes th e temp orary schedu le, an d a llow s the t emp orary schedule t o be cu stomiz ed to a particular w eek ’ s need s. To sel ect the da ys wh ich are to be activated , ent er the d esired number 1- 7 (M onday = 1).
– 45 – Programming Device Timers General Information D ev i ce t i me rs co ns is t o f a n O N t i me & a n O FF t im e , a n d s el e ct e d d a y s o f t he week in wh ich th ey ar e ac tive. Ther e ar e up to 2 0 ti mers th at c an b e used t o control vari ous d evices, such as lights or applianc es.
– 46 – Programming Device Timers (cont ’ d) 00 ON TI ME ? 00:00 PM Enter th e time y ou wan t the d evic e turned on usi ng 00:0 1 - 11: 59 format . When the di splay show s the d es ired time, pr ess th e * key t o m ove to the AM /PM field . Pres s any key 0-9 to chan ge the AM/ PM in dica tion.
– 47 – Event Log Procedures General Information The sy stem ha s the a bili ty to r ecord variou s event s in a hi st ory l og wh erein each even t is rec orded in one of fi ve categ ories (list ed b elow) , with the time an d date of its occur renc e.
– 48 – Event Logging Procedures (continued) 4. Use the [3] & [1] key s (for next and previou s ca teg ories r es pec tively) to displa y the c ateg orie s of even ts. Press [8] to select a category and display the f irst ev ent. Pres s [8] again for ea ch su bsequ ent even t.
– 49 – Testing The System (To Be Conducted Weekl y) Using the 5 TEST Key The TEST key puts your s ystem in to Test mo de, which al lows each prot ection p oint to be ch ecked f or prop er opera ti on. 1. Disarm the system and close all pr otected windows, doors, etc.
– 50 – Fire Alarm System Your fir e alarm sy stem (if installed ) is on 24 hou rs a day, p rov iding continu ous pro tecti on. I n the even t of an emer gen cy, th e sm oke and h eat detectors au tomaticall y send signals to your Control , triggering a loud interru ptin g soun d from the key pad an d the op tional ex teri or sou nder s.
– 51 – Trouble Conditions Typical Trouble Disp lays The w ord CHEC K on the K eypad ’ s display, accompanied b y a rapid "beepin g" at th e Key pad, indi cates tha t ther e is a troubl e cond iti on in the system . To silence the beeping sound f or tr oubl e conditions , press a ny key .
– 52 – Trouble Conditions (cont ’ d) Power Failure If the POWER indica tor is off, opera ting pow er fo r the sy stem has stopp ed and is inoperative. CALL FOR SERVICE IM MEDIATELY. If the POWER indicat or is on, but th e messag e " AC LOSS " is disp layed , the K eypad i s oper ating on ba ttery pow er on ly.
– 53 – Recommendations For Proper Protection The following recommendations for the location of fire and burglary detection devices help provid e proper coverage for the protected premises.
– 54 – Recommendations For Proper Protection (cont ’ d) In addition, we recommend the following: In stall a smok e det ect or in side ev ery bedr oom w her e a sm oker sleep s. Instal l a smo ke det ector in side bedr ooms wh ere electric al appli ances (su ch as p ortab le heaters, air conditione r s or humidifiers) are used.
– 55 – Emergency Evacuation Establi sh an d regu larl y p ractic e a pl an of esc ape in the ev ent of fir e. Th e foll owin g step s are recom mend ed by th e Na ti onal Fir e Pro tec tion A ssoc iati on: 1. Posi tion y our de tector or your inter ior an d/or ext erior soun der s so th at they can be heard by all oc cupan ts.
– 56 – Maintaining Your System Taking Care of Your System The c omp onen ts of y our secur ity syst em are d esign ed to be a s fre e of maint enanc e as p ossibl e. How ever , ther e ar e so me t hing s you can do t o mak e sure that your system is i n reliabl e working con dition.
– 57 – Maintaining Your System (cont ’ d) Silencing Low Battery Warning Tones at the Keypad The keyp ad ’ s warn ing tones c an b e sil enced by perf or ming an OFF s equen ce (cod e plu s OF .
– 58 – Quick Guide To System Functions FUNCTION PROCEDURE COMMENTS Check Zones Press [ ✱ ]. To view faulte d zones when is system not ready Display All Descrip tors Press and hol d [ ✱ ] for 5 seconds . Displays all alpha descriptors programmed by installer.
– 59 – Quick Guide To System Functions (cont ’ d) FUNCTION PROCEDURE COMMENTS Delete a Us er Enter master/manager code . Press CODE [8]. Enter user no. to be deleted. Enter master/mana ger code. Press 1 (Yes) at prom pt. Master & M anager level us ers can delete us ers.
– 60 – Summary Of Audible Notification (Alpha Display Keypads) SOUND CAUSE DISPLAY LOUD, INTERRUPT ED* K eypad & Ext ernal FIRE AL ARM FIRE is displayed; descriptor of zone in alarm is displayed. LOUD, CONTINUOUS* K eypad & Ext ernal BURGLARY/ AUDIBLE EM ERGENCY ALARM ALARM is dis played; descriptor of zone in alarm is also displayed.
– 61 – UL NOTICE: This is a “ GRADE A ” system. “ FEDERAL COMMUNICA TIONS COMMISSION (FCC) Part 15 STATEMENT ” This equipm ent has been tested to FCC requir ements and has been fo und acceptable for us e.
– 62 – “ FEDERAL COMMUNICA TIONS COMMISSION (FCC) Part 68 NOTIC E This eq uipment compl ies with Part 68 of the F CC rul es. O n the fr ont cov er of thi s equ ipment i s a label that contai ns, amo ng other i nformati on, the FCC registr ation num ber an d ringer equ ivalen ce number (R EN) for this e quipme nt.
– 63 – CANADIAN DEPART MENT OF COMMUNICATIONS (DOC ) STAT EMENT NOTICE The Canadian Department of Communicat ions label identifi es certified equipment. This c ertific ation means that the equi pment meets cert ain telecommunic ations network protect ive, operational and safety requirements .
– 64 – WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced desi gn security system, i t does not off er guaranteed protec tion agains t burglary or f ire or other emergency. Any alarm sys tem, whether c ommercial or res idential, is s ubject to compromis e or failure t o warn for a variety of reasons.
– 65 – Index #70 command ......................................... 41 4285 or 42 86 VI P module ................... 8, 41 AC Loss .................................................. 52 Access A nother P artition ........................ 20 Access Do or .
– 66 – POWER/R EADY INDIC ATO R ............... 12 Quick Arming .................................... 12, 14 Quick Bypa ss ......................................... 28 Quick Gu ide ..................................... 58, 5 9 Ready ...............
– 67 – LIMITED WARRANT Y Honeyw ell Internatio nal Inc., 165 Ei leen Way, Syo sset, New York 11791, war rants its prod uct(s) to b e in conf orman ce with i ts own pl ans a nd specif icati ons and.
– 68 –.
– 69 –.
– 70 –.
– 71 –.
¬19#l N5943-6V 2 5/04 R ev. A 165 Eileen W ay , Syosset, New Y ork 11791 Cop yr ight © 2004 Honeyw ell Inter national, Inc. www .
Ein wichtiger Punkt beim Kauf des Geräts Honeywell VISTA-50P (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Honeywell VISTA-50P noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Honeywell VISTA-50P - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Honeywell VISTA-50P reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Honeywell VISTA-50P erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Honeywell VISTA-50P besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Honeywell VISTA-50P verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Honeywell VISTA-50P. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Honeywell VISTA-50P gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.