1 Thank you for buying this energy efficient water heater from A.O. Smith Water Products Company . We appreciate your confidence in our products. Y ou should thoroughly read this manual before installation and/or operation of this water heater .
2 CERT AIN MODELS ARE EQUIPPED WITH SIDE PLUMBING CONNECTIONS FOR SP ACE HEA TING. THE HOT AND COLD FITTING ASSEMBLIES (P ART #900126-2) CAN BE ORDERED THROUGH THE MANUFACTURER. REPLACEMENT P ARTS Replacement parts may be ordered through authorized servicers or distributors.
3 GENERAL SAFETY INFORMA TION EXTERNAL DAMAGE Do not operate the water heater until it has been fully checked out by a qualified technician, if the water heater: • Has been exposed to fire or damage. • Displays evidence of sooting. • Produces steam or unusually hot water .
4 the heater . Such pans should have a minimum length and width of at least 2 inches greater than the diameter of the heater and should be piped to an adequate drain. Drain pans suitable for these heaters are available from your dealer or A. O. Smith Water Products Company , 5621 W .
5 torque when attaching gas supply pipe to thermostat gas inlet. The thermostat inlet has a pad for use with a backup wrench. Apply joint compounds (pipe dope) sparingly and only to the male threads of pipe joints. Do not apply compound to the first two threads.
6 FIGURE 5 FIGURE 6 FIGURE 7 FIGURE 8 FLUE EXTENSIONS There are three optional extension kits available. Any combination of the three kits can be chosen; however , only one kit can be used vertically and/or horizontally . (See Figures 10 and 1 1.) VENTING CLEARANCES • 18” minimum in all directions from any obstruction that may interfere.
7 W ARNING At no time can more than one V ertical and/or one Horizontal V ent Kit be used. VERTICAL (EXTENSION KIT) HEIGHT It is simple to determine which kit is needed for vertical height.
8 T ABLE 2. *See models and rating plate attached to the water heater for specific model number and other detailed information. W ARNING Be sure vent pipe is properly connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation.
9 4. First remove the 3” horizontal extension from the elbow . Starting with the long end (with four securing holes), place the 6” diameter vent elbow over the 3” diameter elbow . Bend the round end “oval” to fit the flared oval end of the jacket top.
10 FIGURE 26 12 . Four wood screws are supplied to temporarily attach the collar to the exterior wall of the building. However , other types of screws may have to be substituted depending on the material used in the construction of the exterior wall. FIGURE 27 13.
11 Use the simple equation below, chart and drawing to find the length of expansion of the telescoping flue sections. Because of manufacturing tolerances, place the telescoping extension on the water heater and adjust the height (“X” Dimension) and mark the point.
12 8. Making sure the 6” diameter elbow is centered around the 3” diameter flue, secure the 6” diameter vent pipe using two sheet metal screws at the connection of the elbow and 6” vertical extension. FIGURE 41 9. The standard vent kit includes a 6” diameter extension pipe which is used when “E” dimension over 6 1/2”.
13 17. Connect the vent cap by sliding its end over the 3” diameter extension pipe and O-ring. NOTE: T o facilitate ease of assembly of the vent cap to the 3” pipe, a soap solution can be applied to the O-ring gasket. FIGURE 50 18. The vent cap has 4 holes around the outer edge.
14 FIGURE 57 5. Making sure the 6” diameter elbow is centered around the 3” diameter flue, secure the 6” diameter vent pipe using four sheet metal screws at the connection of the jacket top. FIGURE 58 6. The standard kit includes a single piece of 3” flue and 6” vent pipe which will not be used in conjunction with the horizontal kit.
15 14. Place the vent cap in the vent collar assembly . FIGURE 67 15. The vent cap has 4 holes around the outer edge. Remove the 4 screws used to temporarily attach the collar to the exterior wall. Then secure the vent cap assembly with the vent collar assembly to the exterior wall using the same 4 screws.
16 FIGURE 74 Use the simple equation below , chart and drawing to find the length of expansion of the telescoping flue sections. Because of manufacturing tolerances, place the telescoping extension on the water heater and adjust the height (“X” Dimension) and mark the point.
17 8. The standard kit includes a single piece of 3” flue and 6” vent pipe which will not be used in conjunction with the optional horizontal kit. FIGURE 82 9.
18 4 screws used to temporarily attach the collar to the exterior wall. Then secure the vent cap assembly with the vent collar assembly to the exterior wall using the same 4 screws. NOTE: Screws are supplied; however , substitution may be necessary depending on the exterior wall material.
19 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. LIGHTING INSTRUCTIONS A. This appliance has a pilot which must be lighted by hand.
20 TEMPERA TURE REGULA TION DANGER THIS W A TER HEA TER IS EQUIPPED WITH AN ADJUST ABLE THERMOST A T TO CONTROL W A TER TEMPERA TURE. HOT W A TER TEMPERA TURES REQUIRED FOR AUT OMA TIC DISHW ASHER AND LAUNDRY USE CAN CAUSE P AINFUL SCALDING WITH POSSIBLE SERIOUS AND PERMANENT INJURY .
21 be called to determine the reason for limit operation and thus avoid repeated thermostat replacement. Lower the temperature adjustment dial setting on the new control. VENTING HA VE VENTING SYSTEM CHECKED EVERY SIX MONTHS FOR OBSTRUCTIONS AND/OR DETERIORA TION IN VENT PIPING.
22 TROUBLESHOOTING Please check guidelines below . For your safety , water heater service should be performed only by a qualified service technicia n. Read the GENERAL SAFETY INFORMA TION section first. PROBLEM POSSIBLE MALFUNCTION SERVICE TO BE PERFORMED POSSIBLE SOLUTION NO HOT W A TER 1) No pilot A.
23 THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONL Y . I f the glass lined tank in this water heater shall prove upon examination by A. O. Smith Corporation (the warrantor) to have leaked during.
5621 W . 1 15TH STREET , ALSIP , IL 60803 PHONE: 1-800-433-2545 F AX: 1-800-433-2515 www .hotwater .com / email: par ts@hotwater .com.
Ein wichtiger Punkt beim Kauf des Geräts A.O. Smith FDV (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie A.O. Smith FDV noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für A.O. Smith FDV - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von A.O. Smith FDV reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über A.O. Smith FDV erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon A.O. Smith FDV besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von A.O. Smith FDV verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit A.O. Smith FDV. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei A.O. Smith FDV gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.